ML19329C479

From kanterella
Jump to navigation Jump to search
Requests re-evaluation Using Corrected ECCS Model Per 10CFR50 App K.Licensing Actions Involving CP & OL Applications or Reload Cores Impacted Until Evaluation Model Fully Complies W/Requirements
ML19329C479
Person / Time
Site: Davis Besse 
Issue date: 12/02/1976
From: Ross D
Office of Nuclear Reactor Regulation
To: Suhrke K
BABCOCK & WILCOX CO.
Shared Package
ML19329C474 List:
References
NUDOCS 8002140857
Download: ML19329C479 (1)


Text

s N

I v

UMtTED STATES

[

NUCLEAR REGULATORY COMMISs!ON

~.

3:* 1 j

WASHINGTON. D. C. 20655

/

DEt 2 19h.

D D

Mr. Kenneth E. Suhrke Manager, Licensing

~

Babcock and Wilcox O "D) 3 I 4

P.O. Box 1260 g

g 1y Lynchburg, Va. 24505

Dear Mr. Suhrke:

During the course of our review of emergency core cooling system (ECCS) evaluation models, it has come to our attention that use of a nucleate boiling heat transfer correlation during blowcown after critical heat flux (CHF) is first predicted, may not confom to the requirements of Appendix K to 10 CFR 50. The criteria for compliance with Aopendix K have been established by the NRC staff and were discussed with you.

This is similar to the matter identified with respect to the Combustion J

Engineering (CE) evaluation model.

Based on our exoerience in connection with develocing a correction for the CE model, we conclude that there are acceptable correlations which can be used and which would have a small effect on calculated peck clac temperature.

We are instructing all operating plants which have been evaluated for ECCS performance using your model to submit a re-evaluation using a model corrected to preclude the use of a nucleate boiling heat transfer correlation during blowdown after CHF-has been predicted by the approved correlation.' Since the expected effect on peak cladding temperature is small, continued operation of these plants within the limits of tne existing Technical Specifications, in the interim until the required recalculations are performed, will continue to prcvide reasonabl.

assurance that calculated peak clad temperature will remain within the limits of 10 CFR 50. 6 and will result in no undue risk to the public health and safety.

However, it is essential that you submit the corrected model for our evaluation as soon as possible since new licensing actions involving CP and OL applications or reload cores may be impacted until your evaluation model is fully in compliance with Appendix K.

Sincerely, it x. pd,,,I

(

Denw... Ross, Jr., Assistant Director for Reactor Safety Division of Systems Safety Office of Nuclear Reactor Regulation 8002140 g