ML19329B742
| ML19329B742 | |
| Person / Time | |
|---|---|
| Site: | Davis Besse |
| Issue date: | 07/31/1970 |
| From: | Richard Anderson, Ayers J, Ohara N MICHIGAN, UNIV. OF, ANN ARBOR, MI |
| To: | |
| References | |
| NUDOCS 8002060748 | |
| Download: ML19329B742 (43) | |
Text
_ _ _ _
3 M atory Rfe Cyl"
- *^
kusind w vr,.. 4ffph.
//
HYDROLOGICAL SURVEYS FOR THE LOCUST POINT POWER PLANT PART IV.
The 1969 PHYTOPLANKTON COLLECTIONS IN THE LOCUST POINT REGION pF4 3
John C. Ayers II b
a Robert F. Anderson pyg }7 ggg Norbert W. O'Hara g
gg Ccccias s
man &
s so s46 m
n
\\
1 I
I Under ccntract with j
i
\\
The Toledo Edison Company l
I l
/
D Special Report No. 45 of the
/
c7 00CKEHD usto Great Lakes R_ search Division j
g The University of Michigan I
/
!b ;1.UG171972 > 3 Ann Arbor, liichigan f
NINdcN July 1970 x,
yj.,
OfCKETC;.ERK/
6 N '. ~.,
?f\\
n <, ; ---
,,a e
\\
8002 0 tio 7 k8 p 8
c THE 1969 PHYTOPLANKTON COLLECTIONS IN THE LOCUST POINI REGION on May 15 and 16, 1969, phytoplankton collections were made at 11 stations in the immediate environs of Locust Point.
Figure 1 presents the station positions of the May survey. Appendix Tables 1-12 inclusive give the total phytoplankton species composition and the phytoplankton species and numbers collected at each station of the May survey. Table 1 summarizes the dominant species of the May collections.
During 21-29 October 1969 phytoplankton collections were made at 20 stations in the immediate environs of Locust Point.
Figure 2 shows the station positions of the October survey. The total area covered in October was not significantly different from that covered in May; the difference in number of stations collected is due to insertion of several stations at positions that were not occupied in May. Appendix Tables 13-33 give the total phytoplankton species population as well as the phytoplankton species and numbers collected at each of the Locust Point stations in October. Table 2 summarizes the dominant species of the October collections.
The Locust Point phytoplankton population in May of 1969 was composed almost entirely of diatoms, with very minor contributions by green algae and blue-green algae.
In May the heavily dominant species were the diatoms Fragilaria capucina, Melosira binderana and Melosira granulata combined (combined because their colonies were commonly intertwined, and though cells could be seen well enough-to count by focusing the microscope through, the underneath cells could not be seen well enough to identify them to species), and Diatoma tenue v.
elongatum with the latter being consistently the third most abundant species in the station collections. One to-five species of green algae were taken at each station of the May survey, a total of 14 green algae species in all being collected. At each station of the May survey representatives of the blue-green.
r
4 algae, identified as Oscillatoria spp., were collected in small numbers; no examples of the *roublesome species Aphanizomenon flos-acune were taken during this survey.
The October phytoplankton collections were characterized by having a much greater variety of species present at each station than had been the case in May.
They were also characterized by having lower total numbers of cells per liter and generally lower numbers of cells per species. In the October collec-tions the diatoms remained dominant by a ight' margin in numbers of cells, with green algae of 55 species in second place by numbers, and blue-green algae belonging to 16 species in third place numberswise. Blue-greens of the genus Aphanizomenon were present in all but two stations of the October survey. The relative decline in diatom dominance, and the rise of green algae and blue-greens into nearly-dominant positions between May and October can at present be taken only to possibly represent a seasonal deterioration in basic water quality which may be typical of the region, or which may be only a part of a more widespread peculiarity of 1969.
Flagellates, not found in the May collections, had become abundant by October.
As a means of showing and comparing the relative phytoplankton populations in the immediate environs of Locust Point in 1969, the following comparison table has been devised.
Judging water quality by the types of the three most dominant (numerous) plankters present (Table 2) indicates that the poorest water was found at Station PL-1 off Turtle Creek. At this station the dominant organism was the blue-green alga Oscillatoria, the second most dominant was the blue-green Aphanizomenon flos-acuse, and the diatom Cvelotella occupied third place.
Another station adjudged to exhibit poor water quality was Station PL-7 where the dominant organism was the flagellate Cryptomonas with the blue green,
{
Comparison Table Locust Point phytoplankton, May versus October 1969 May October Mean No. of Range, Nos.
Mean No. of Range, No s.
No. of cells / liter cells / liter No. of cells / liter cells / liter species
- per station per station species
- per station per station 6
6 Diatoms 17 4,450,000 1.9-ll.9x10 20 1,039,000 0.1-1. 7x10 3
6 Green Algae 14 4,450 1-17 x10 55 666,000 0.07-1.3 x10 3
Flagellates 0
6 321,000 85-671x10 3
6 Blue-Greens 1
5,000 1-15x10 16 423,0D0 0.07-1.4x10
- Identified species, unidentified single species (sp.), and unidentified plural species (spp.) combined.
Oscillatoria in second place and the diatom Coscinodiscus rothii third.
Continuing with these criteria, water of questionable quality (in which the second and third dominants were the blue-green Oscillatoria and the flagellate Crvotomonas respectively) was present at Stations PL-13, PL-17, PL-18, and PL-20.
Table 2 permits other assessments of relative quality of water at the i
October stations. If we reason that stations with diatoms in the three most dominant positions were stations with good quality of water, we may then indicate that good quality of water was present at Stations PL-10, PL-ll, and PL-12.
In a more realistic sense, however, it is not good nor meaningful practice to attribute to such indications of water quality at the various stations anything more than a certain illustrativ'e value. In the clearer waters of eastern Lake Michigan small but discrete water masses of visible color differences can, under good observing conditions, be seen to be progressing one af ter the other in the alongshore current.
Color indications of separate water masses could not be expected to be visible in the turbid alongshore currents of Locust Point.
The i
patchy distributions of poor, intermediate, and good water quality as read from the October phytoplankton dominants can, in the present state of our knowledge of the Locust Point area, be interpreted only to mean that the alongshore currents of Lake Erie are in autumn like those of Lake Michigan in that' (in the relatively calm weather when small boats can work) there pass along the shore discrete water-masses of different origins with different phytoplankton Contents.
i 6
l l
l
)
Figure 1.
STATION MAP OF LOCUST POINT PROJECT M AY 19 6 9, SAMPLING TRUE NORTH
/
0 12 2. 5 m ile s O
7 Il X l.4 miles e4 X8
\\
X5 O
10 O IOOyords 3
09 accesst O2 O6 J
LOCUS T 4
(S POINT O
O 15 f
\\g
,, s+*
\\
x l<
g
,0 O 13 CAMP O
COMPLETE STATION PERRY X
SHORT STATION "
APPENDIX Table 1 Phytoplankton Population Locust Point, 15-16 May 1969 Diatoms Diatoma tenue v. elongatum Melosira binderana Melosira granulata Synedra ulna Synedra acus Fragilaria intermedia Fragilaria capucina Fragilaria crotonensis Asterionella formosa Cyclotella spp.
Navicula spp.
Tabellaria fenestrata Surirella spp.
Nitzschia spp.
Stephanodiscus spp.
Cymbella spp.
Gomphonema spp.
Greens Ulothrix spp.
Pediastrum duplex Scenedesmus abundans Scenedesmus quadricauda Dictyosphaerium pulchelium Ankistrodesmus spp.
Ankistrodesmus falcatus Scenedesmus spp.
Micractinium pusillum Oocystis solitaria Lagerheimia longiveta Golenkinia radiata Act'inastrum hantzschii
)
Closteriopsis longissima Blue-Greens Oscillatoria spp. -
1
4 APPENDIX Table 2 Phytoplankton Composition Station LPP-1, Locust Point 15 May 1969 Organism No. of Colonies Cells per Liter 3,747 Oscillatoria sp. (BG)
Frag 11 aria crotonensis (D) 1,874 51,524 937 Ankistrodesmus f alcatus (G)
Diatoma tenue v. elongatum (D) 42,156 287,598 Melosira binderana (D) 66,513 526,482 Asterionella formosa (D) 6,558 49,651 Fragilaria capucina (D) 49,651 2,243,636 7,494 Cyclotella sp. (D) 937 Navicula sp. (D) 937 Oocystis solitaria (G)
Scenedesmus quadricauda (G) 937 Syr.edra ulna (D) 937 Tabellaria fenestrata (D) 4,684 30,914 937 Surirella sp. (D) 3,206,000 i
f e
APPENDIX Table 3 Phytoplankton Composition Station LPP-2, Locust Point 15 May 1969 Organism No. of Colonies Cells per Liter Synedra ulna (D) 17,666 Synedra acus (D) 6,625 Tabellaria fenestrata (D) 2,208 15,458 Pediastrum duplex (G) 2,208 Melosira binderana &
M. granulata combined (DD) 516,742 4,891,385 Diatoma tenue v. elongatum (D) 99,374 1,355,896 Asterionella formosa (D) 24,291 249,538 Fragilaria crotonensis (D) 4,417 117,040 Fragilaria capucina (D) 105,998 5,284,462 Cyclotella sp. (D) 6,625 Scenedesmus abundans (G) 2,208 Ooc: stis solitaria (G) 2,208 Osc111atoria sp. (BG) 2,208 11,953,000
APPENDIX Table 4
+
. Phytoplankton Composition 4
Station' LPP-3, Locust Point
- y 15 May 1969 h-,
-t Organism No. of Colonies Cells per Liter s
Diatona tenue v. elongatum (D) 47,917 242,675 1,546 Oscillatoria sp. (BG) 1,546 Ulothrix sp. (G)
Melosira binderens (D) 61,828 930,512 4,637 Synedra acum (D) 6,183 Synedra ulna (D)
Fragilaria intermedia (D) 17,003 630,646 Fragilaria capucina (D) 4,637 98,925 1,916,000 a
e b
I 4
APPENDIX Table 5 Phytoplankton Composition Station LPP-4, Locust Point 15 May 1969 Orwanism No. of Colonies Cells per Liter Synedra ulna (D) 13,138 Tabe11 aria fenestrata (D) 10,049 57,202 Diatoma tenue v. elongaman (D) 66,478 672,510 Melosira binderana &
M. granulata combined (DD) 202,526 937,649 Fragilaria crotonensis (D) 1,546 58,748 Asterionella formosa (D) 17,006 135,275 Fragilaria capucina (D) 85,030 3,237,324 Lagerheimia longiseta (G) 773 Golenkinia radiata (G) 773 Cyclotella sp. (D) 3,865 Oscillatoria sp. (BG) 2,319 Dictyosphaerium pulchellum (G) 1,546 Scenedesmus quadricauda (G) 773 Synedra acus (D) 2,319 5,124,000 APPENDIX Table 6 Phytoplankton Composition Station LPP-6, Locust Point 15 May 1969 Organism No. of Colonies Cells eer Liter Fragilaria crotonensis (D) 2,132 14,924 Surirella sp. (D) 1,066 6,396 Synedra ulna (D) 1,066 Synedra acvs (D) 1,066 Dictyosphaerium pulchelium (G)
Ankistrodesmus sp. (G) 1,066 Oscillateria sp. (BG) 2,132 Tabe11 aria fenestrata (D) 7,462 33,046 Diatoma tenue v. elongatum (D) 74,620 380,562 Melosira binderana &
M. granulata combined (DD) 105,534 891,176 Fragilaria capucina (D) 49,036 1,557,426 Scenedesmus abundans (G) 1,066 i
Closteriopsis longissima (G) 1,066 2,892,000 4.__
APPENDIX Table 7 Phytoplankton Composition Station LPP-7, Locust Point 15 May 1969 Organism No. of Colonies Cells per Liter Synedra ulna (D) 4,986 Surirella sp. (D) 997 Oocystis solitaria (G) 997 Melosira binderana &
M. granulata combined (DD) 101,714 622,253 Diatoma tenue v. elongatum (D) 50,857 283,205 Asterionella formosa (D) 9,972 81,770 Tabe11 aria fenestrata (D) 3,989 12,964 Fragilaria capucina (D) 49,860 1,471,867 Micractinium pusillum (G) 1,994 Oscillatoria sp. (BG) 1,994 2,483,000 e
e -
APPENDIX Table 8 Phytoplankton Composition Station LPP-9, Locust Point 15 May 1969 Organism No. of Colonies Cells per Liter Oscillatoria spp. (BG) 5,888 1,472 Micractinium pusillum (G) 1,472 Scenedesmus quadricauda (G)
Synedra ulna (D) 8,832 Cyclotella spp. (D) 10,304 Gomphonema sp. (D) 1,472 Stephanodiscus sp. (D) 2,944 Synedra acus (D) 7,360 Melosira binderana &
M. granulata combined (DD) 113,344 1,149,632 Asterionella formosa (D) 5,888 27,968 Tabe11 aria fenestrata (D) 1,472 8,832 Diatoma tenue v. elongatum (D) 75,072 450,432 Fragilaria crotonensis (D) 2,944 79,488 Fragilaria capucina (D) 41,216 585,856 2,341,000 l L
.c
APPENDIX Table 9 Phytoplankton Composition Station LPP-10, Locust Point 16 May 1969 Ornanism No. of Colonies Cells per Liter Fragilaria crotonensis (D) 6,183 74,191 15,457 Synedra acus (D) 6,183 Synedra ulna (D) 15,457 Oscillatoria spp. (BG)
Melosira binderana &
M. granulata combined (DD) 420,417 3,159,309 Fragilaria espucina (D) 108,196 2,550,323 Scenedesmus sp. (G) 3,091 9,274 Cyclotella sp. (D)
Ankistrodesmus falcatus (G) 3,091 Nitzschia sp. (D) 9,274 Diatoma tenue v. elongatum (D) 272,034 1,415,815 Asterionella formosa (D) 12,365 83,465 Tabe11 aria fenestrata (D) 6,183 27,823 7,372,000 l.
4 i
\\
APPENDIX Table 10 Phytoplankton Composition Station LPP-12, Locust Point 16 May 1969 Orzanism No. of Colonies Cells per Liter Synedra ulna (D) 4,314 Oscillatoria sp. (BG) 6,470 Actinastrum hantzschii (G) 2,157 Diatoma tenue v. elongatum (D) 42,058 Melosira binderana &
208,131
'd.
granulata cotbined (DD) 73,331 815,270 Asterionella formosa (D) 4,314 38,822 Tabe11 aria fenestrata (D) 5,392 20,490 Fragilari.a capucina (D) 21,570 628,707 Scenedesmus abundans (G) 1,078 Cyclotella sp. (D) 3,235 1,728,000 APPENDIX Table 11 Phytoplankton Composition Station LPP-13, Locust Point 16 May 1969 Organism No. of Colonies Cells per Liter Scenedesmus quadricauda (G) 1,546 Oscillatoria spp. (BG) 12,368 Jtephanodiscus sp. (D) 9,276 Synedra acus (D) 10,822 Dictyosphaerium pulchelium (G) 6,184 Ankistrodesmus sp. (G) 3,092 Actinas trum hantzschii (G) 3,092 Cyclotella spp. (D) 9,276 Micractinium pusillum (G) 3,092 Synedra ulna (D) 6,184 Tabellaria fenestrata (D) 6,184 30,920 Diatoma tenue v. elongatum (D) 123,680 1,004,900 Melosira binderana &
M. granulata combined (DD) 336,462 5,468,202 Fragilaria enpucina (D) 40,196 1,456,332 Cymbella sp. (D) 1,546 Asterionell.a formosa (D) 4,638 30,920 i.
8,057,000
APPENDIX Table.12 Phytoplankton Composition Station LPP-15, Locust Point 15 May 1969 Organism No. of Colonies Cells per Liter 6,624 Oscillatoria spp. (BG) 2,208 Ankistrodesmus sp. (G)
Navicula sp. (D) 1,104 4,416 Synedra acus (D)
Fragilaria crotonensis (D) 1,104 37,536 Melostra binderana &
M. granulata combined (DD) 59,616 623,760 Diatoma tenue v. elongatum (D) 44,160 195,408 Tabe11 aria fenestrata (D) 9,936 40,848 Asterionella formosa (D) 1,104 11,040 Fragilaria capucina (D) 28,704 1,065,360 Synedra ulna (D) 2,208 Cyclotella sp. (D) 6,624 Closteriopsis longissima (G) 1,104 1,998,000 r l
.)
Table 1 Summary of May phytoplankton dominants Sention Mcat Dominant Second Dominant Thisd Dominant LPP-1 Fragilaria capucina (D)
Melosira binderana (D)
Diatoma tenue v. elongatum (D)
LPP-2 Fragilaria capucina (D)
Melosira binderana &
Diatoma tenue v. elongatum (D)
M. granulata ccmbined (DD)
LPP-3 Melosira binderana (D)
Fragilaria intermedia (D)
Diatoma tenue v. elongatum (D)
LPP-4 Fragilaria capucina (D)
M. binderana & granulata combined (DD)
Diatoma tenue v. elongatum (D)
LPP-6 Fragilaria capucina (D)
H. binderana & granulata combined (DD)
Diatoma tenue v. elongatum (D)
LPP-7 Fragilaria capucina (D)
M. binderana & granulata combined (DD)
Diatoma tenue v. elongatum (D)
LPP-9 M. binderana & granulata combined (DD)
Fragilaria capucina (D)
Diatoma tenue v. elongatum (D)
LPP-10 M. binderana & granulata combined (DD)
Fragilaria capucina (D)
Diatoma tenue v. elongatum (D)
LPP-12 M. binderana & granulata combined (DD)
Fragilaria capucina (D)
Diatoma tenue v. elongatum (D)
LPP-13 M. binderana & granulata combined (DD)
Fregilaria capucina (D)
Diatoma tenue v. elongatum (D)
LPP-15 Fragilaria capucina (D)
M. binderana & granulata combined (DD)
Diatoma tenue v. elongatum (D)
rigure 2.
STATION MAP OF LOCUST POINT OCTOBER 1969 S AMPLING TRUE NORTH
/
25* MAG.
33* MAG.
22*TRUE 30*TRUE 3 8' M AG.
3 2.5 miles 35
- TRUF/
9 2
1.4 miles 5
60* MAG.
\\
57'TRU I
5 milet 8
IOOyds.
access r 7
gg 18 4
LOCUST c,
POINT p;an, 4o. MA.
d site 10
/
37*
TRUE 15 1
0 CAMP Q
COMPLETE STATION PERRY O
SHORT STATION
APPENDIX Table 13 Phytoplankton Population Locust Point Samples October 1969 Diatoms Greens (Cont.)
Coscinodiscus spp.
Ulothrix spp.
Coscinodiscus rothii var. subsalsa Oocystis spp.
Cyclotella spp.
Docystis borgei Melosira granulata Oocystis solitaria Melosira binderana Schroederia sp.
Melosira sp.
Schroederia judayi Stephanodiscus niagarae Schroederia setigera Stephanodiscus sp.
Actinastrum hantzschii Fragilaria intermedia Closterium sp. (desmid)
Fragilaria crotonensis Closteriopsis longissima Fragilaria construens Tribonema spp.
Fragilaria capucina Cosmarium sp. (desmid)
Fragilaria pinnata Nephrocytium sp.
Synedra sp.
Lagerheimia longiseta Nitzschia spp.
Gloeocystis spp.
Surirella sp.
Gloeocystis major Navicula sp.
Tetrandron sp.
Amphora ovalis Tetraudron caudatum Diatoma vulgare Tetraudron lunula Meridion circulare Tetraedron minimum Tetraudron trigonum Greens Selenastrum bibraianum Selenastrum sp.
Coelastrum sphaericum Dimorphococcus sp.
Coelastrum microporum Dimorphococcus lunatus Coelastrum reticulatum Kirchneriella sp.
Coelastrum sp.
Kirchneriella lunaris Pediastrum duplex Kirchneriella elongata Pediastrum simplex Crucigenia quadrata Pediastrum spp, Crucigenia spp.
Dictyosphaerium pulchelzum Quadrigula lacustris Dictyosphaerium ehrenoergianum Colenkinia radiata Ankistrodesmus falcatus Tetrastrum spp.
Ankistrodesmus spp.
Soraatrum spinulosum Scenedesmus abundans Treubaria setigerum Scenedesmus sp.
Sorastrum sp.
Scenedesmus acuminatus Scenedesmus bijuga Blue-Greens Scenedesmus dimorphus Scenedesmus incrassatulus Oscillatoria spp.
Scenedesmus quadricauda Anabaena spp.
Scenedesmus armatus Anabaena circinalis L
Scenedesmus arcuatus Aphanizomenon flos-aquae l
Scenedesmus acutiformis Aphanizomenon sp.
Staurastrum sp. (desmid)
Gomphosphaeria spp.
APPENDIX Table 13 (Cont.)
Blue-Greens (Cont. )
Gomphosphaeria lacustris Chroccoccus sp.
Aphanocapsa sp.
Microcystis aeruginosa Merismopedia sp.
Chroococcus limneticus Chroococcus dispersus Dactylococcopsis smithii Coelosphaerium sp.
Coelosphaerium naegelianum Fla2ellates Peridinium spp.
Cryptomonas spp.
Chlamydomonas spp.
Mallomonas spp.
Euglena sp.
Cystodinium sp.
t,
APPENDIX Table 14 Phytoplankton Composition Station PL-1, Locust Point 24 October 1969 Organism No. of Colonies Cells per Liter Nephrocytium sp. (G) 14,840 TetraHdron minimum (G) 3,710 Chroococcus limneticus (BG) 7,420 Tetraedron caudatum (C) 3,710 Coscinodiscus rothii (D) 18,550 Microcystis aet*ginosa (BG) 7,420 Cystodinium sp. (V) 18,550 Crucigenia sp. (G) 11,130 Pediastrum spp. (G) 25,970 Comphosphaeria spp. (BG) 25,970 Schroederia judayi (G) 3,710 Anabaena sp. (BG) 14,840 Tetraedron lunula (G) 85,330 Ankistrodesmus f alcatus (G) 22,260 Gloeocystis spp. (G) 40,810 Dictyosphaerium pulchelium (G) 66,780 Gloeocystis major (G) 33,390 Oscillatoria spp. (BG) 359,870 Docystis spp. (G) 81,620 Coelastrum sphaericum (G) 59,360 Ulothrix spp. (G) 51,940 Cyclotella spp. (D) 92,750 Aphanizomenon flos-aquae (BG) 159,530 Cryptomonas spp. (F) 29,680 Scenedesmus bijuga (G) 63,070 Scenedesmus abundans (G) 22,260 Scenedesmus quadricauda (G) 40,810 Scenedesmus dimorphus (G) 14,840 Closterium sp. (G) 3,710 Nitzschia sp. (D) 3,710 TriFinema sp. (G) 7,420 Sorastrum spinulosa (G) 3,710 Chlamydomonas spp. (F) 37,100 Occystis solitaria (G) 25,970 1,461,000 2
APPENDIX Table 15 Phytoplankton Composition Station PL-2, Locust Point 24 Octcber 1969 Organism No. of Colonies Cells per Liter Chroococcus limneticus (BG) 3,710 Pediastrum spp. (G) 29,680 Coelastrum sphaericum (G) 63,070 Gloeocystis sp. (G) 11,130 Dictyosphaerium pulchelium (G) 29,680 Gomphosphaeria lacustris (BG) 25,970 Occystis borgei (G) 25,970 Docystis solitaria (G) 33,390 Cyclotella spp. (D) 215,180 Coscinodiscus rothii (D) 89,040 Cryptomonas spp. (F) 115,010 Chlamydomonas spp. (F) 107,590 Ankistrodesmus falcatus (G) 59,360 Mallomonas sp. (F) 11,130 Scenedesmus abundans (G) 107,590 Scenedesmus quadricauda (G) 44,520 Scenedesmus incrassatulus (G) 22,260 Scenedesmus bijuga (G) 33,390 Scenedesmus armatus (G) 37,100 Cosmarium sp. (G) 3,710 Closterium sp. (G) 7,420 Scenedesmus acuminatus (G) 11,130 Nephrocytium sp. (G) 14,840
~
Tetraddron sp. (G) 14,840 Actinastrum hantzschii (G) 11,110 Crucigenia quadrata (G) 33,390 Aphanizomenon flos-aquae (BG) 48,230 Osci? 'toria spp. (BG) 196,630 Ulothrix cp. (G) 63,070 Anabaena sp. (BG) 11,130 Nitzschia spp. (D) 51,940 Melosira granulata (D) 215,180 916,370 Kirchneriella sp. (G) 3,710 Golenkina radiata (G) 3,710 Merismopedia sp. (BG) 3,710 Stephanodiscus niagarae (D) 3,710
.Schroederia judayi (G) 14,840 Peridinium sp. (F) 11,130 2,489,000
APPENDIX n
Table 16 Phytoplankton Composition Station PL-3, Locust Point 24 October 1969 Organism No. of Colonies Cells per Liter Staurastrum sp. (G) (desmid) 14,840 Crucigenia spp. (G) 11,130 40,810 Tetraedron lunula (G) 18,550 Tetrastrum sp. (G) 3,710 Ankistrodesmus falcatus (G) 18,550 Cystodinium sp. (F) 7,420 Merismopedia sp. (BG) 3,710 Anabaena sp. (BG) 3,710 Kirchneriella elongata (G) 3,710 Gloeocystis sp. (G) 7,420 Oscillatoria spp. (BG) 178,080 Oocystis sp. (G) 18,550 Cryptomonas spp. (F) 63,070 Chlamydomonas spp. (F) 63,070 Cyclotella spp. (D) 51,940 Coscinodiscus sp. (D) 63,070 Peridinium spp. (F) 3,710 Pediastrum spp. (G) 37,100 Ulothrix sp. (G) 11,130 Dictyosphaerium pulchellum (G) 7,420 Coelastrum sphaecicum (G) 44,520 Scenedesmus quadricauda (G) 40,810 Scenedesmus abundans (G) 85,330 Scenedesmus bijuga (G) 14,840 Scenedesmus incrassatula (G) 7,420 Melostra granulata (D) 185,500 712,320 Actinastrum hantzschii (G) 3,710 Tetraudron trigonum (G) 3,710 Gomphosphaeria sp. (BG) 7,420 Gloeocystis major (G) 7,420 Chroococcus dispersus (BG) 3,710 Schroederia judayi (G) 3,710 1,554,000 -
~
APPENDIX Table 17 Phytoplankton Composition Station PL-4, Locust Point 24 October 1969 Ornanism No. of Colonies Cells per Liter D:etylococcopsis smithii (BG) 11,130 Kirchneriella sp. (G) 7,420 Stephanodiscus sp. (D) 18,550 Tetrastrum sp. (G) 11,130 Nephrocytium sp. (G) 18,550 Golenkinba radiata (G) 11,130 Cystodinium sp. (F) 14,840 Staurastrum sp. (G) (desmid) 14,840 Coscinodiscus spp. (D) 200,340 Cyclotella spp. (D) 753,130 Coelastrum sphaericum (G) 96,460 Euglena sp. (F) 18,550 Oocystis solitaria (G) 29,680 Docystis spp. (instly borgei) (G) 92,750 Dictyosphaerium pulchellum (G) 51,940 Gomphosphaeria spp. (lacustris, aponina) (BG) 66,780 Crucigenia spp. (G) 33,390 Pediastrum spp. (G) 37,100 Tetrasdron caudatum (G) 14,840 Tetrasdron lunula (G) 44,520 Gloeocystis sp. (G) 18,550 Merismopedia sp. (BG) 3,710 Actinastrum hantzschii (G) 29,680 Cryptomonas spp. (F) 352,450 Chlamydomonas spp. (F)~
155,820 Ankistrodesmus f alcatus (G) 81,620 Peridinium spp. (F) 70,490 Mallomonas spp. (F) 59,360 Scenedesmus abundans (G) 233,730 Scenedesmus incrassatulus (G) 44,520 Scenedesmus bijuga (G) 44,520
'cenedesmus quadricauda (G) 44,520 Scenedesmus armatus (G) 29,680 Closteriopsis 'longissima (G) 14,840 Oscillatoria spp. (BG) 630,700 Ulothrix spp. (G) 118,720 Aphanizomenon flos-aquae (BG) 422,940
~
Anabaena spp. (BG) 29 480 Nitzschia spp. (D) 29,o80 Melosira granulata (D) 118,720 629,990 4,592,000
APPENDIX Table 18 Phytoplankton Composition Station PL-5, Locust Point 24 October 1969 Organism No. of Colonies Cells per Liter Tetrastrum sp. (G) 7,420 Pedtastrum spp. (G) 7,420 Cealastrum sp. (G) 74,200 r,loeocystis sp. (G) 7,420 Tetraudron lunula (G) 7,420 Stephanodiscus sp. (D) 3,710 Oocystis borgei (G) 29,680 Coscinodiscus spp. (D) 44,520 Cyclotella spp. (D) 40,810 Docystis solitaria (G) 3,710 Chlamydomonas spp. (F) 29,680 Cryptomonas spp. (F) 33,390 Oscillatoria spp. (BG) 11,130 Scenedesmus abundans (G) 55,650 Nitzschia sp. (D) 7,420 Ulothrix sp. (G) 11,130 Melosira granulata (D) 166,950 638,120 Closteriopsis longissima (G) 3,710 Crucigenia sp. (G) 7,420 Golenkinia radiata (G) 3,710 Microcystis aeruginosa (BG) 7,420 Tetraudron caudatum (G) 3,710 Cosmarium sp. (G) 3,710 Comphosphaeria sp. (BG) 3,710 Dictyosphaerium pulchelium (G) 3,710 1,049,000 O
APPENDIX Table 19 Phytoplankton Composition Station PL-6, Locust Point 24 October 1969 Organism No. of Colonies Cells per Liter Coelastrum sp. (G) 5,562 Pediastrum duplex (G) 927 Peridintum sp. (F) 2,781 Coscinodincus sp. (D) 22,248 Cyclotelle. spp. (D) 40,788 Oscillatoria spp. (BG) 31,518 Dictyosphaerium pulchellum (G) 10,197 Melosira granulata (D) 137,196 643,338 Ankistrodesmus f alcatus (G) 6,489 Anabaena sp. (BG) 927 Scenedesmus spp. (G) 31,518 Ulothrix sp. (G) 2,781 Flagellates (F) 50,058 Staurastrum sp. (G) (desmid) 927 Anabaena circinalis (BG) 927 Pediastrum simplex (G) 927 Aphanizomenon flos-aquae (BG) 2,781 Occystis sp. (C) 16,686 871,000 Note: Lots of Detritus.
e i.
-)
APPENDIX Table 20 Phytoplankton Composition Station PL-7, Locust Point 21 October 1969 Organism No. of Colonies Cells per Liter Nephrocytium sp. (G) 5,565 Cystodinium sp, (F) 11,130 Navicula sp. (D) 5,565 Merismopedia sp. (BG) 3,710 Coscinodiscus rothii (D) 270,830 Cyclotella spp. (D) 183,645 Stephanodiscus niagarae (D) 1,855 Docystis sp. (borgei?) (G) 92,750 Chlamydomonas spp. (F) 53,795 Cryptomonas spp. (F) 358,015 Mallomonas sp. (F) 24,115 Peridinium sp. (F) 16,695 Ankistrodesmus sp. (G) 14,840 Scenedesmus abundans (G) 70,490 Scenedesmus quadricauda (G) 51,940 Scenedaecua dimorphus (G) 16,695 Scanedesmus incrassatulus (G) 12,985 Scenedes=ue bijugn (G) 5,565 Scenedesmus arcuatus (G) 1,855 Gloeocystis sp. (G) 16,695 Gomphosphaeria spp. (BG) 27,825 Pediastrum spp. (G) 127,995 Dictyosphaerium spp. (pulchellum, ehrenbergianum) (G) 152,110 Coelastrum spp. (G) 33,390 Tetrandron sp. (G) 11,130 Coelosphaerium sp. (BG) 1,855 Actinastrum hantzschii (G) 5,565 Euglena sp. (F) 7,420 Anabaena sp. (BG) 5,565 Oscillatoria spp. (BG) 283,815 Ulothrix spp. (G) 64,925 Tribonema sp. (G) 12,985 Nitzschia spp. (D) 25,970 Aphanizomenon sp. (BG) 16,695 Melosira granulata (D) 40,810 185,500 Fragilaria capucina (D) 1,855 48,230 2,229,000
APPENDIX Table 21 Phytoplankton Composition Station PL-8, Locust Point 21 October 1969 Organism No. of Colonies Cells per Liter Tetrastrum spp. (G) 40,810 Colenkinia radiata (G) 7,420 Staurastrum sp. (G) (desmid) 7,420 Microcystis aeruginosa (BG) 7,420 Nitzschia sp. (D) 22,260 Chroococcus limneticus (BG) 3,710 Crucigenia sp. (G) 3,710 14,840 Tetraudron trigonum (G) 3,710 Coscinodiscus rothii (D) 233,730 Oocystis borgei (G) 51,940 Cryptomonas spp. (F) 289,380 Cyclotella spp. (D) 85,330 Chlamydomonas spp. (F) 178,080 Ankistrodesmus falcatus (G) 122,430 Peridinium sp. (F) 14,840 Mallomonas sp. (F) 18,550 Scenedesmus quadricauda (G) 148,400 Scenedesmus abundans (G) 118,720 Scenedesmus bijuga (G) 74,200 Scenedesmus dimorphus (G) 25,970 Pediastrum spp. (G) 70,490 Coelastrum sphaericum (G) 81,620 Coelastrum microporum (G) 3,710 Gloeocystis sp. (G) 22,260 TetraEdron lunula (G) 51,940 Schroederia judayi (G) 11,130 Comphosphaeria app. (BG) 37,100 Dictyosphaerium pulchellum (G) 63,070 Dictyosphaerium ehrenbergianum (G) 14,840 Closteriopsis longissima (G) 7,420 Stephanodiscus niagarae (D) 1.1,130 Anabaena spp. (BG) 11,130 Aphanizomenon flos-aquae (BG) 148,400 Ulothrix spp. (G) 285,670 Oscillatoria spp. (BG) 129,850 Melosira binderana (D) 22,260 51,940 Melosira granulata (D) 63,070 586,180 Fragilaria capucina (D) 37,100 415,520 Kirchneriella sp. (G) 7,420 Aphanocapsa sp. (BG) 3,710 Cystodinium sp. (F) 11,130 Coelastrum reticulatum (G) 7,420 Tetraudron caudatum (G) 3,710 Scenedesmus acutiformis (G) 7,420 Sorastrum spinulosa (G) 7,420 3,520,000 '
APPENDIX Table 22 Phytoplankton Composition Station PL-9, Locust Point 21 October 1969 Organism No. of Colonies Cells per Liter Staurastrum sp. (G) 18,550 Closteriopsis longissima (G) 14,840 Tetraudron caudatum (G) 7,420 Cystodinium sp. (F) 11,130 Sorastrum spinulosa (G) 3,710 Coscinodiscus rothii (D) 207,760 Tetraedron lunula (c) 85,330 Chlamydomonas spp. (F) 126,140 Scenedesmus abundans (G) 152,110 Scenedesmus quadricauda (G) 66,780 Scenedesmus bijuga (G) 37,100 Scenedesmus dimorphus (G) 22,260 Oocystis spp. (G) 55,650 Cryptomonas spp. (F) 307,930 Cyclotella spp. (D) 48,230 Ankistrodesmus falcatus (G) 22,260 Peridinium sp. (F) 7,420 Mallomonas sp. (F) 18,550 Tetrastrum spp. (G) 44,520 Pediastrum spp. (G) 122,430 Coelastrum sphaericum (G) 40,810 Stephanodiscus niagarae (D) 3,710 Gloeocystis major (G) 11,130 Dictyosphaerium pulchellum (G) 63,070 Gloeocystis sp. (G) 22,260 Gomphosphaeria sp. (BG) 3,710 Ulothrix spp. (G) 278,250 Aphanizomenon flos-aquae (BG) 144,690 Oscillatoria spp. (BG) 63,070 Melosira granulata (D) 59,360 382,130 Fragilaria pinnata (D) 3,710 44,520 Fragilaria capucina (D) 37,100 482,300 Nitzschia sp. (D, 3,710 Schroederia judayi (G) 3,710 Merismopedia sp. (BG) 3,710 Golenkinia radiata (G) 3,710 Scenedesmus armatus (G) 14,840 2,949,000 APPENDIX Table 23 Phytoplankton Composition Station PL-10, Locust Point 21 October 1969 Organism No. of Colonies Cells per Liter Gloeocystis sp. (G) 22,260 Merismopedia sp. (BG) 5,565 Microcystis aeruginosa (BG) 14,840 Staurastrum sp. (G) 5,565 Dimorphococcus sp. (G) 5,565 Lagerheimia longiseta (G) 3,710 Tetraudron sp. (G) 1,855 9,275 Aphanocapsa sp. (BG)
Melosira binderana (D) 1,855 9,275 Crucigenia sp. (G) 11,130 Chroococcus limneticus (BG) 1,855 Chlamydomonas sp. (F) 27,825 Docystis solitaria (G) 11,130 Oocystis sp. (G) 20,405 Scenedesmus abundans (G) 50,085 Scenedesmus dimorphus (G) 12,985 Scenedesmus quadricauda (G) 20,405 Scenedesmus incraasatulus (G) 20,405 Cryptomonas spp. (F) 87,185 Peridinium and other flagellates (F) 12,985 Ankistrodesmus f alcatus (G) 20,405 Cyclotella spp. (D) 152,110 Coscinodiscus rothii (D) 79,765 Melosira granulata (D) 24,115 144,690 Schroederia setigera (G) 11,130 Dictyosphaerium spp. (pulchellum, ehrenbergianum) (G) 53,795 Pediastrum spp. (G) 51,940 Coelastrum spp. (G) 44,520 Nitzschia spp. (D) 27,825 Gomphosphaeria sp. (BG) 11,130 Diatoma vulgare (D) 1,855 Oscillatoria spp. (BG) 187,355 Ulothrix spp. Q3) 64,925 Aphanizomenon flos-aquae (BG) 57,505 Anabaena sp. (BG) 11,130 Tribonema spp. (G) 33,390 J
Fragilaria capucina (D) 12,985 211,470 Cystodinium sp. (F) 3,710 Stephanodiscus niagarae (D) 1,855 Actinastrum hantzschii (G) 1,855 Schroederia judayi (G) 1,855 Stephanodiscus sp. (D) 3,710 Closterium sp. (G) 1,855 Fragilaria intermed!a (D) 1,855 70,490 1,404,000
?
APPENDIX Table 24 Phytoplankton Composition Station PL-11, Locust Point 21 October 1969 Organism No. of Colonies Cells oer Liter Nephrocytium sp. (G) 3,710 Gomphosphaeria sp. (BG) 5,565 Lagerheimia longiseta (G) 1,855 Schroederia judayi (G) 3,710 Stephanodiscus niagarae (D) 3,710 Scenedesmus dimorphus (G) 9,275 Scenedesmus armatus (G) 16,695 Actinastrum hantzschii (G) 5,563 Scenedesmus bijuga (G) 5,365 Scenedesmus quadricauda (G) 50,085 Scenedesmus abundans (G) 53,795 Coelastrum spp. (G) 40,810 Pediastrum spp. (G) 55,650 Gloeocystis sp. (G) 7,420 Anabaena spp. (BG) 37,100 Aphanocapsa sp. (BG) 3,710 Oocystis borgei (G) 44,520 Gocystis solitaria (G) 16,695 Ankistrodesmus f alcatus (G) 25,970 Cryptomonas spp. (F) 220,745 Chlamydomonas spp. (F) 37,100 Dictyosphaerium pulchelium (G) 44,500 Coscinodiscus rothii v. subsalsa (D) 233,730 Stephanodiscus spp. (D) 27,825 Nitzschia sp. (D) 1,855 Navicula sp. (D) 5,565 Amphora ovalis (D) 1,855 Frag 11 aria crotonensis (D) 1,855 64,925 Fragilaria construens (D) 1,855 77,910 Fragilaria intermedia (D) 16,695 302,365 Melosira binderana (D) 3,710 11,130 Melosira granulata (D) 42,665 341,320 Oscillatoria spp. (BG) 70,490 Ulothrix spp. (G) 142,835 Tribonema spp. (G) 40,810 Aphanizomenon flos-aquae (BG) 79,765 Crucigenia sp. (G) 1,855 7,420 Cyclotella sp. (D) 7,420 Coelosphaerium sp. (BG) 1,855 1
Staurastrum sp. (G) 1,855 Chroococcus sp. (BG) 1,855 Closterium sp. (G) 3,710 Flagellates (F) 16,695 Surirella sp. (D) 3,710 2,140,000.
APPENDIX Table 25 Phytoplankton Composition Station PL-12, Locust Point 21 October 1969 Organism No. of Colonies Cells per Liter P:diastrum simplex & P. duplex combined (G) 64,925*
Dictyosphaerium pulchelium (G) 20,405 Coelastrum spp. (G) 29,680 Staurastrum sp. (G) 5,565 Stephanodiscus niagarae (D) 5,565 Cosmarium sp. (G) 1,855 Closterium sp. (G) 1,855 Ankistrodesmus sp. (G) 1,855 Nitzschia sp. (D) 1,855 Surirella sp. (D) 3,710 Scenedesmus spp. (G) 98,315*
Cyclotella spp. (D) 40,810 Flagellates:
Chlamydomonas, Peridinium,
& Cryptomonas combined (F) 187,355 Coscinodiscus rothii v. subsalsa (D) 189,210 Oscillatoria spp. (BG) 42,665 Docystis sp. (G) 22,260 Nephrocytium sp. (G) 1,855 Fragilaria crotonensis (D) 3,710 20,405 Synedra sp. (D) 3,710 Fragilaria intermedia & F. construens combined (DD) 11,130 365,435 Aphanizomenon flos-aquae (BG) 31,535 Melosira granulata (D) 40,810 393,260 Ulothrix sp. (G) 12,985 Tribonema spp. (G) 109,445 1,656,000
- Lots of detritus, difficult to identify.
9 a -. -.
5 -
APPENDIX Table 26 Phytoplankton Composition Station PL-13, Locust Point 21 October 1969 Organism No. of Colonies Cells per Liter i
Kirchneriella lunaris (G) 7,420 Kirchneriella elongata (G) 1,855 Crucigenia sp. (G) 3,710 22,260 Tetraudron caudatum (G)
~
16,695 Microcystis aeruginosa (BG) 5,565 Staurastrum sp. (G) 7,420 Stephanodiscus sp. (D) 1,855 Actinastrum hantzschii (c) 3,710 Chlamydomonas spp. (F) 157,675 Cryptomonas spp. (F) 354,305 Occystis spp. (G) 120,575 Coscinodiscus rothii (D) 64,925 Cyclotella spp. (D) 116,865 Ankistrodesmus falcatus (G) 129,850 Mallomonas spp. (F) 92,750 Peridinium spp. (F) 31,535 Scenedesmus abundans (G) 166,950 Scenedesmus quadricauda (G) 90,895 Scenedesmus dimorphus (G) 37,100 Scenedesmus bijuga (G) 14,840 Scenedesmus incrassatulus (G) 31,535 Gomphosphaeria lacustris (BG) 29,680 Melosira binderana (D) 3,710 22,260 Melosira granulata (D) 29,680 189,210 Pediastrum spp. (G) 105,735 Dictyosphaerium spp. (pulchellum, ehrenbergianum)(G) 105,735 Dimorphococcus lunatus (G) 5,565 Schroederia judayi (G) 12,905 Coelastram spp. (mostly sphaericum) (G) 102,025 Gloeocyt.cis spp. (G) 27,825 Merismopedia sp. (BG) 7,420 Closteriopsis longissima (G) 5,565 Tribonema spp. (G) 42,665 Aphanizomenon flos-aquae (BG) 146,545 Oscillatoria spp. (BG) 421,085 Ulothrix spp. (G) 278,250 Synedra sp. (D) 5,565 Nitzschia sp. (D) 12,985 Anabaena sp. (BG) 11,130 Fragilaria capucina (D) 24,115 866,285 Fragilaria crotonensis (D) 1,855 44,520 Scenedesmus arcuatus (G) 1,855 Chroccoccus sp._(BG) 1,855 Cosmarium sp. (G) 3,710 Cystodinium sp. (F) 12,985 Closterium sp. (G) 3,710 3,943,000 i.
~
APPENDIX Table 27 Phytoplankton Composition Station PL-14, Locu.at Point 27 October 1969 Organism No. of Colonies Cells per Liter Tetrastrum spp. (G) 29,680 Stephanodiscus niagarae (D) 3,710 Coelastrum reticulatum (G) 14,840 Chroccoccus limneticus (BG) 3,710 Staurastrum sp. (G) 7,420 Meriscopedia sp. (BG) 7,420 Golenkinkt radiata (G) 3,710 Quadrigula lacustris (G) 3,710 Crucigenia sp. (G) 3,710 18,550 Sorastrum spinulosa (G) 3,710 Crypt >monas spp. (F) 333,900 Chlamvdomonas spp. (F) 148,400 Oocystis spp. (G) 103,880 Scenedesmus quadricauda (G) 166,950 Scenedesmus abundans (G) 207,760 Scenedesmus dimorphus (G) 11,130 Scenedesmus armatus (G) 11,130 Coelastrum sphaericum (G) 92,750 Coscinodiscus rothii (D) 96,460 Cyclotella spp. (D) 100,170 Peridinium spp. (F) 63,070 Tetraudron caudatum (G) 7,420 Tetraedron lunula (G) 55,650 Dictyosphaerium pulchelium (G) 29,680 Pediastrum spp. (G) 74,200 Schroederia judayi (G) 11,130 Comphosphaeria lacustris (BG) 18,550 Dictyosphaerium ehrenbergianum (G) 25,970 Mallomonas spp. (F) 33,390 Ankistrodesmus falcatus (G) 11,130 Gloeocystis sp. (G) 14,840 Gloeocystis major (G) 3,710 Aphanizomenon flos-aquae (BG) 322,770 Ulothrix spp. (G) 107,590 Tribonema spp. (G) 48,230 Anabcena sp. (BG) 3,710 Oscillatoria spp. (BG) 70,490 Nitzst'11a sp. (D) 11,130 Melosira binderana (D) 18,550 140,980 Fragilaria crotonensis (D) 11,130 89,040 Fragilaria pinnata (D) 11,130 482,300 Fragilaria capucina (D) 37,100 597,310 Melosira granulata (D) 25,970 230,020 Nephrocytium sp. (G) 3,710 Treubaria setigerum (G) 7,420 Kirchneriella sp. (G) 3,710 Closterium sp. (G) 7,420 3,843,000
s APPENDIX Table 28 Phytoplankton Composition Station PL-14, Locust Point 27 October 1969 Organism No. of Colonies Cells per Liter Crucigenia spp. (G) 3,710 59,360 Sorastrum sp. (G) 7,420 Stephanodiscus niagarae (D) 11,130 Staurastrum sp. (G) 3,710
'Closterium sp. (G) 7,420 Dictyosphaerium pulchelium (G) 11,130 Schroederia judayi (G) 3,710 i
Coscinodiscus rothii (D) 81,620 Cyclotella spp. (D) 77,910 Scenedesmus abundans (G) 215,180 Scenedesmus quadricauda (G) 51,940 Ooeystis spp. (G) 74,200 Nitzschia spp. (D) 241,150 Cryptomonas spp. (F) 215,180 Ankistrodesmus f alcatus (G) 18,550 Tetraedron lunula (G) 51,940 Peridinium spp. (F) 25,970 Comphosphaeria sp. (BG) 18,550 Coelastrum spp. (G) 55,650 Cystodinium sp. (F) 3,710 Tetrastrum sp. (G) 18,550 Pediastrum sp. (G) 22,260 Dictyosphaerium ehrenbergianum (G) 25,970 Aphanizomenon flos-aquae (BG) 122,430 Ulothrix sp. (G) 3,710 Oscillatoria spp. (BG) 122,430 Anabaena sp. (BG) 11,130 Melosira granulata (D) 144,690 363,580 Tetraedron caudatum (G) 3,710 1,929,000 APPENDIX Table 29 Phytoplankton Composition Station PL-16, Locust Point 28 October 1969 Organism No. of Colonies Cells per Liter Colenkinia radiata (G) 11,130 Coscinodiscus rothii (D) 226,s10 Merismopedia sp. (BG) 7,420 Euglena sp. (F) 3,710 Cyclotella spp. (D) 1,202,040 Scenedesmus bijuga (G) 81,620 Scenedesmus abundans (G) 122,430 Scenedesmus quadricauda (G) 40,810 Scenedesmus dimorphus (G) 37,100 Oocystis spp. (G),,
122,430 Cryptomonas spp. -(F) 263,410 Chlamydomonas spp'. (F) 81,620 Peridinium spp. (F) 48,230 Mallomonas sp. (F) 18,550 Actinastrum hantzschii (G) 29,680 Dictyosphaerium pulchellum (G) 92,750 Coelastrum sphaericum (G),
74,200 Comphosphaeria lacustris (EG) 44,520 Crucigenia sp. (G) 22,260 Staurast:am sp. (G) 14,840 Gloeocystis spp. (G);
29,680 Gloeocystis major (G) 11,130 Schroederia judayi (G)_
14,840 Pediastrum spp. (G) 44,520 Ankistrodesmus falcatus (G) 14,840 Closterium sp. (G) 3,710 Oscillatoria spp. (BG) 1,035,090 Ulothrix spp. (G) 140,980 Aphanizomenon flos-aquae (BG) 289,380 Nitzschia spp. (D) 293,090 Anabaena spp. (BG) 25,970 Melosira spp. (D) 44,840 222,600 Tetrastrum wh. (G) 7,420 Aphanocapsa'ap. (BG) 3,710 4
4,682,000 9
Y.
1
6-
~ ~ ~ ~
APPENDIX Table 30
^
Phytoplankton Composition Station PL-17, Locust Point 29 October 1969 Organism No. of Colonies Cells per Liter Selenastrum bibraianum (G) 1,855 Euglena s;, (F) 3,710 Merismopedia sp. (BG) 1,855 Mallomonas spp. (F) 33,390 Peridinium spp. (F) 31,535 Cryptomonas spp. (F) 250,425 Chlamydomonas spp. (F) 38,955 j
Cyclotella spp.-(D) 560,210 Coscinodiscus rothii (D) 142,835 Docystis spp. (G) 29,680 Oocystis solitaria (G) 9,275 Ankistrodesmus falcatus (G) 1,855 Scenedesmus bijuga (G) 11,130 Scenedesmus incrassatulus (G) 11,130 Scenedesmus quadricauda (G) 38,955 Scenedesmus dimorphus (G) 14,840 Scenedesmus abundans (G) 33,390
)
Coelastru= sphaericum (G) 38,955 Dictyosphaerium pulchellum (G) 33,390 Gomphosphaeria lacustris (BG) 27,825 Actinastrum hantzschii (G) 3,710 Gloeocystis sp. (G) 16,695
hroederia judayi (G) 14,840 Pediastrum spp. (G) 24,115 Staurastrum sp. (G) 1,855 Crucigenia sp. (G) 7,420 Ulothrix spp. (G) 68,365 Aphanizomenon flos-aquae (BG) 35,245 Oscillatoria spp. (BG) 276,395 Anabaena sp. (BG) 9,275 Nitzschia sp. (D) 22,260 Melosira granulata (D) 27,825 122,430 Stephanodiscus niagarae (D) 1,855 1,919,000
~
~
APPENDIX Table 31 Phytoplankton Composition Station PL-18, Locust Point 29 October 1969 Organism No. of Colonies Cells per Liter Diatoma vulgare (D) 1,855
- Coelastrum sp. (G) 24,115 Cystodinium sp. (F) 9,275 Nephrocytium sp. (G) 3,710 Actinastrum hantzschii (G) 9,275 Crucigenia sp. (G) 12,985 Gloeocystis sp. (G) 12,985 Coscinodiscus rothii (D) 94,605 Cyclotella spp. (D) 899,675 Dimorphococcus lunatus (G) 11,130 Dictyosphaerium pulchellum (G) 48,230 Ankistrodesmus falcatus (G) 25,970 Schroederia judayi (G) 11,130 Gomphosphaeria spp. (BG) 33,390 Chlamydomonas spp. (F) 153,965 Cryptomonas spp. (F) 228,165 Peridinium, Mallomonas and other flagellates (F) 46,375 Pediastrum spp. (G) 27,825 Scenedesmus bijuga (G) 24,115 Scenedesmus quadricauda (G) 46,375 Scenedesmus incrassatulus (G) 55,650 Scenedesmus dimorphus (G) 40,810 Scenedesmus armatus (G) 38,955 Oocystis spp. (G) 100,170 Oscillatoria spp. (BG) 487,865 Aphanizomenon flos-aquae (BG) 25,970 Ulothrix spp. (G) 61,215 Tribonema spp. (G) 38,955 Anabaena spp. (BG) 3d,955 Melosira sp. (granulata?) (D) 5,565 40,810 Nitzschia spp. (D) 61,215 Synedra sp. (D) 3,710 Kirchneriella sp. (G) 7,420 Aphanocapsa sp. (BG) 1,855 Staurastrum sp. (G) 1,855 Stephanodiscus niagarae (D) 3,710 Tetraudron sp. (G) 1,855 Chroococcus sp. (BG) 1,855 2,738,000,
- t
d APPENDIX Table 32 Phytoplankton Composition Station PL-19, Locust Point 29 October 1969 Organism No. of Colonies Cells per Liter Cystodinium sp.
(F) 7,420 Stephanodiscus niagarae (D) 5,565 Coelosphaerium nacgelianum (BG) 5,565 Nitzschia sp. (D) 1,855 Coscinodiscus rothii (D) 111,300 Cryptomonas spp. (F) 168,805 33,390 Chlamydomonas spp. (F)
Peridinium and other flagellates (F) 42,665 Occystis sp. (borgei?) (G) 57,505 Oocystis solitaria (G) 9,275 Pediastrum sp. (G) 18,550 Dictyosphaerium pulchellum (G) 50,085 Coelastrum spp. (G) 35,245 Gloeocystis sp. (G) 9,275 Scenedesmus incrassatulus (G) 24,115 Scenedesmus dimorphus (G) 31,535 Scenedesmus bijuga (G) 20,405 Scenedes=us quadricauda (G) 35,245 Scenedesmus abundans (G) 35,245 Scenedesmus armatus (G) 16,695 Gomphosphaeria sp. (BG) 9,275 Actinastrum hantzschii (G) 9,275 Cyclotella spp. (D) 806,925 Staurastrum sp. (G) 3,710 Closteriopsis longissima (G) 3,710 Oscillatoria spp. (BG) 458,185 Ulothrix spp. (G) 51,940 Tribonema sp. (G) 12,985 Anabaena spp. (BG) 12,985 Aphanizomenon flos-aquae (BG) 37,100 j
Melosira granulata (D) 40,810 218,890 Synedra spp. (D) 29,680 Navicula sp. (D) 18,550 Tetra'dron sp. (G) 3,710 d
Microcystis aeruginosa (BG) 5,565 Stephanodiscus sp. (D) 1,855 Selenastrum sp. (G) 1,855 Lagerheimia longiseta (G) 1,855 Schroederia judayi (G) 1,855 Meridion circulare (D) 1,855 Ankistrodesmus f alcatus (G) 5,565 2,417,000
.y APPENDIX Table 33 Phytoplankton Composition Station PL-20, Locust Point 29 October 1969 Organism No. of Colonies Cells per Liter Pediastrum sp. (G) 20,405 Coscinodiscus rothii v. subsalsa (D) 42,665 Anabaena sp. (BG) 16,695 Stephanodiscus niagarae (D) 1,855 Schroederia sp. (G) 9,275 Nephrocytium sp. (G) 5,565 Coelastrum sp. (G) 14,840 Staurastrum sp. (G) 3,710 Actinastrum hantzschii (G) 5,565 Ankistroedesmus fal:atus (G) 3,710 Closterium sp. (G)~
3,710 Closteriopsis longissima (G) 7,420 Gomphosphaeria sp. (BG) 1,855 Stephanodiscus sp. (D) 1,855 Chroococcus sp. (BG) 5,565 Scenedesmus spp. (G) 83,475 Oscillatoria spp. (BG) 395,115 Aphanizomenon flos-aquae (BG) 96,460 Ulothrix sp. (G) 7,420 Melosira sp. (granulata?) (D) 12,985 Fragilaria intermedia (D) 1,855 14,840 Stephanodiscus spp. &
Cyclotella spp. combined (DD) 601,020*
Flagellates: Cryptomones, Peridinium,
& Chlamydomonas combined (F) 135,415*
Dictyosphaerium pulchellum (G) 38,955 Docystis spp. (G) 55,650 Synedra spp. & some Nitzschia (DD) 63,070*
Tribonema spp. (G) 25,970 1,675,000
- Lots of detritus, very difficult to identify.
8 i Table 2
.c Summary of October phytoplankton dominants Station Most Dominant Second Dominant Third Dominant PL-1 Oscillatoria spp.-(BG)
Aphanizomenon flos-aquae (BG)
Cyclotella spp. (D)
PL-2 Melosira granulata (D)
Cyclotella spp. (D)
Oscillatoria spp. (BG)
PL-3 Melosira granulata (D)
Oscillatoria spp. (BG)
Scenedesmus abundans (G)
PL-4 Cyclotella spp. (D)
Oscillatoria spp. (BG)
Melosira granulata (D)
PL-5 Mel asira granulata (D)
Coelastrum spp. (G)
Scenedesmus abundans (G)
PL-6 Melosira granulata (D)
Flagellates (F)
Cyclotella spp. (D)
PL-7 Cryptomonas spp. (F)
Oscillatorta spp. (BG)
Coscinodiscus rothii (D)
PL-8 Melosira granulata (D)
Fragilaria capucina (D)
Cryptomonas spp. (F)
PL-9 Fragilaria capucina (D)
Melosira granulata (D)
Cryptomonas spp. (F)
PL-10 Fragilaria capucina (D)
Cyclotella spp. (D)
Melosira granulata (D)
PL-ll Melosira granulata (D)
Fragilaria intermedia (D)
Coscinodiscus rothii (D)
PL-12 Melosira granulata (D)
Fragilaria intermedia &
Coscinodiscus rothii (D)
F. construens (DD)
PL-13 Fragilaria capucina (D)
Oscillatoria spp. (BG)
Cryptomonas spp. (F)
PL-14 Fragilaria capucina (D)
Fragilaria pinnata (D)
Cryptomonas spp. (F)
PL-15 Melosira granulata (D)
Nitzschia spp. (D)
Cryptomonas spp. (F) &
Scenedesmus abundans (G)
PL-16 Cyclotella spp. - (D)
Oscillatoria spp. (BG)
Nitzschia spp. (D)
PL-17 Cyclotella spp. (D)
Oscillatoria spp. (BG)
Cryptomonas spp. (F)
PL-18 Cyclotella spp. (D)
Oscillatoria spp. (BG)
Cryptomonas spp. (F)
PL-19 Cyclotella spp. (D)
Oscillatoria spp. (BG)
Melosira granul'ata (D) 1 PL-20 Stephanodiscus spp. &
Oscillatoria spp. (BG)
Flagellates (F)
Cyclotella spp. (DD)
-