ML19329B727

From kanterella
Jump to navigation Jump to search
Deficiency Rept Re Steam Generator Weld Records:During B&W QC Audit at Barberton Works,Filler Wire Qualification Test Repts Found Incomplete for Several Heats of Weld Filler Matls.B&W Rept Pending
ML19329B727
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 01/04/1973
From: Sampson G
TOLEDO EDISON CO.
To:
References
NUDOCS 8002060736
Download: ML19329B727 (1)


Text

..

ff m

. A.M-m 4

e TOLEDO

~

~edmanli c?

CU GuNN J. Season Vice Pres 4dsat. Power January h,1973 QQ Mr. Frank E. Kruesi Directer of Regulatory Operations U U U.S. Atc=ic Energy Cc=nission 205h5 Washington, D.C.

Dceket No. 50-3 6 k

Dear Mr. Kruesi:

which could be considered re-50.55(e)(1)(1), " Conditions You are hereby notified of a situation portable in accordance with 10 CFR Part'"his situatica relates to generaters.

of Construction Per=its".for the Davis-3 ess A recent audit of veld records conducted by ization at their Barberton if steen supply system supplier, 3 L W) C.C organ test reports are ince:-

i terials used in steam generator Works has shcvn that filler wire qualificat on fine the extent' plete for several heats of veld filler =a3 & W is currently reviewin fabrication.

of the inec=plete documentation.

t tion situation within We vill submit a written report on the docu=en a 30 deys.

Yours very truly,

?/

m.

i

/,

S Ml '* *

,$'({,<ll/,,

/

V OJS:cd cc Mr. Boyce H. Grier, Regional Director Region III goo 20so 736 2

TCLEDO, CHIO 42 300 MADISON AVENUE EDISCN PLAZA -

NEDISON CCMP ANY