.w Distribution Docket fit, DEC 16 1976 LWR 1 File J. Stolz L. Engle E. Hylton Occket ilo. 50-346 ME!10RANDUti FOR:

J. !!. Sniczek, Chief, Light Water Reactor Programs Branch, I&E FR0ft:

J. F. Stolz, Chief Light Water Reactors Branch No.1, CP'1

SUBJECT:

CELETIGil OE tlATURAL CIRCULATIO 1 TEST - TOLEDO EDISON C0?!PA4Y (OAVIS BESSE, UtlIT 1)

Pursuant to your amorandum of December 1,1976, we have evaluated the need for requiring a natural circulation test as specified in Regulatorv Guide 1.63 for the elevated steam generator design for Davis Besse, Unit 1 (00-1).

The Toledo Edison Company has r.ot presented any supporting bases in the FSAR wnereby we can compare the efficiency of the raised loop design for J3-1 to tne results for the Oconce 177 FA lowered loop natural circulation tes t.

Therefore, since Davis Besse, Unit 1 is the lead facility for the Oconee 177 FA raised loop design, it is the staff's position that the natural circulation test be conducted for 08-1 during the power escalation chase of testing and that tne DB-1 FSAR be amended to include tne natural circulation test as specified in Requistory Guide 1.68.

Should you have any further questions, please call us.

Origua! S!sned by' John l'.Stols J John F. Stolz, Chief Light W;ter Reactors Branch No.1 Division of Project l'.anagement 50-3 %

NV LWR 1 LWR 1 a ~'e = *

+

_LEng. _ _

JS son..

_.12/3/16._

12/4/

Form AEC-318 (Rev. 943) AICM 0240 W u. e. eovsanassar paintine oprics: se74.sas. nee 8002060 7/9 M,