CU wucteAn0rN(m he.c, o.. m a w -ma Iapr y

F OlA

_89 309 esass

e....,

RESPONbE TO FR F

I l **"iat

?y' P

\\**" )

X ihat INFORMATION ACT (FOIA) REQUEST OCT 191989' tu.it

.i,,,._e-

'htOut 416 h Matthew Brock PART I AGENCY RtCOROS MELE A$lO OM NOT LOCATED (Sec chec&cd t>one.l No spency,0co'06 tubrect to the..ou.St have teen laget.d No oeditionei egency,ecore. aut> pet to the,eouest have te.n locolod hoouetted,0co'Os s't eteststele th,ough enothe, pubhc ditt itiution program bee Comments $.ction g

Agency e.corce sutisect to the,eaut.t that s't scentihed on AppendMe66

)

are ektedy eveiletne to, putdic m. pecten and copying m the IvRC Putihe Document Room PIPO t f.ie.et N W. Wo.hington. DC 7054t.

Agency,ec toc 6.ut. sect to the eequest that see opentib.0 on App.nd,ie si

_ ere t*m0 made eveilabit fe, publec mapection and copying m the y

NRC Pubiec Document Room. ti20 L Ep.et. N W.. Weehmpton. DC. m e soiar unde this iDI A numt v enc,eoutsiv nome.

The nontuop'ete'y ve neon of the psoposati.) that you egr.ed to occept m a teseleton. conyt seison.itt. e memt.e, of my statt ss no. temp mope eseiletdo 10, pubhc enspecten one copyini, et the NRC Putdec Document Room PtPO L 60.et. N W. Wethington, DC. m o tosoe, unoe this iDIA numbo, and,.aut.tv name Arncy..co.a. eut,,.cno the..ou.n.si e...o.noh.a on Appena....i

_may t.e in.p.n.o ena cop..o enho NRC Locei eutd.c Docum ni Room.oenuh.o en the Comments S.ction (nopees is mtoemation on ho. you may otnam occ.ss to end the che's.s to, coscap..co'on piec.c in the NRC Putic Document Room. itPO L $9.at Id W.,

Wash.nDion DC X

      • arv **** *st*>'"h' a'**' '* 'ad*8
  • App. H record s, and t he rel ea s a bl e records on App. I a re encl o m n.co....ut. cno the,cou.si se,. u.n.ei....d is e,oih, f..e,si egncyi.e.ni.

,v,,..no..n e.pon.e io you X

vou -di ne i.a.o by the NRC 'a i... moi ae i 110S" x

in e.e. ei NRC...spon.e i. ibi...ous.t. no iune., enen i., is pn on app..nen., esita Aug u s t_18 6_1989 No _.& A-26 PART 11. A-INFORMATION WITHHILD FROM PU$LIC DISCLOEURE Cene.n mio me on m ine..qu.steo...... t.....sihheio e,o puid.c..oc4u.

.u.suoni i ih,...moison. ee.c,4i

.a eno eo, th...e.on..ieioa m re,i ii

. onion.Ei.C.e, D Any.. e.ee rion,onhe oocumeni. fo,.h.cn o,ii, c.en onh...co.a.. t...n

..ihh.io e,e i.e.no neae e,saanie in, put+c. esp.n.on ena X

copymg m the NRC PutAc Document Room. 2120 L St'.et. N W. Washington, DC e e toide, unow th4 7DiA numt+, ena neoue.tv name CDM8MNTS

    • The fees are for the following:

643 pages of duplication

-100 free pages 543 pages X 0.20 per page = $108.60 2.00(casettetape)

+

W.0.60 8910300045 091019 PDR FOIA BROCK 09-309 PDR SIGihl '1DM. DIRtC10R. DivibiON OF F t M Of INf OMMATION AND PVituC AllON6 blRylCl6

/ nu

/-g m e.>,

(

C RC FORM 464 iPe't 1) tit +s,

y

, PREE00M OF INFORMATlON ACT RESPONSE rDiAcUustRc FOlA 309 DATi- 00i t c 1999 PART R 0- APPLICASLE EXEMPTS 0seS Records outvect to the etouest that are descritied on the enclosed Appendmtell _ I see being withheld 6n then ent6tety or 6n part under the (semptions and for the 'essons set forth tielow pursuant to 5 U.S C 552M enct 19 C.F R 917101 of NRC Regulations-i

t. The wettiheld enformation a peogerly tientifed pursuant to 1accutive Ordet it *(MPIsON il
2. The withheld enformaten veletes solely to the antemel personnel evies and procedures of NRC ff KIMPTION 21
3. f te withhold ontormation is asecahtelty tiempted trom putatic cinctosuee try statute indicated. tiktMPT80N 31

$ettens 14114% of the Atomic Energy Act wNch p'ohituts the 64ctowe of Restucted Date of Formerly Restucted Date 142 U $ C. 2161216bt Secten 147 of the Atomic inergy Act wtuch peoNtnis the 64closwee of Unclassthed $8'epperos informaten 442 U $ C. 2167L

4. The wnhheid mtormaten is e troos secret ce commercel or fmancial mformation that is temp withheld for the 'essontal endicated (EXIMPTION el The enformation se consiO*'td to be confioentiel busmess (p'opretaryt intoemetet h The mformation is consioeved to te peop'etery mformaten pursuant to to Cf R 2 790tdidl.

The tnfoemeten mes submitted end 'ettived en confiOente po'suant to 10 CFR 2 790tdH2 i

A L. Tha withheid mtormaten consists of mie'opency or er'treepent, recores that o's not eie.letde through Oscove*y durmp htigeben (th!MPTION bl Appletable Pnvisepe Deleterative Peacess. D sclosu'e of p'eoecisenal entormation would tone to enNt"4 the open and trent eachenge of eates essenbal to the peIIhe7etive process.

Wheve recoeps are withhem m then entnety the f acts are one stucebly entertwmed with the preoecmenalmfoemeten The's ciso e's no reasonably sep'opabie f actuel N

portions tocause the ro6eese of the f acts would seemet en mowect shoupy mte the prooecisensi process of the opency Attoeney woes product pnwisepe (Documents sweg o'ed tiv en ettome, m sontempianon of litipabon i j Attomew - cient piivilege iConhnenbet t ommunications tietmeen en ettoseev and he her tiient i

6. The withheld ontormaison is esempted from putilic dec60we teteuse ets 04ciosu'e would result m 6 cieetly unwe" anted meesen of po'sonei puvery. IIKLMPTION 61
7. The withheed enformation cons'ets of rectnes compiled for low enfortement purpuses and is temp withheid for the reasonist indicated ftXtMP740N 7) owowe coum renonetiiv de ewecied io miertere we en ecto.comeni n'oceeomg dece se a coum revesone scope. ei,ecoon end focus of en.

toetervent e'toris one thus could posaito, eiton them to ten e action to sh.eid potent.el wronprtomo ce e veoisien of twRC reaueements feom mvesiegators X

Et MPTION 71 Ali i

Deciosure would constitute en unmarranted invasion of personal peevocy it kEMPfl0N 7dCH The enformelen consists of nortes of md.veueis and othee information the dei'losu'e of which could vessonably te ennected to reveel dentites of I

conteentisi soveces it xiMPTiON 7 IDu i

OlHL I4 t

PART W. C-DENYING OFFICIALS Puesvent o 10 CFR 9 26tbi ene tw 9 25 tct of the V $ Nacies' Repuisto', Comm4sion eepulei ons et has t+en cetermired that the mformaten anhheid es enempt team prod.cten cw desciosu'e end that its prooxdon ca o+ciowe is conste'y to the putdi interest The ceesons eesponsible icw the een.ei are those o'hciais scentif ed teion es conveng officiais one the De*ector Divisen of 5'etoom of Informehon end Putdetshons fiervices Office of Aamm>stesten end Raources Management for any ceniets that me, tie onceeied to the f accutive Doec toe for Ot+retions st doi DENYING OFr4CIAL TIT Lt /O'FICE RECORD $ DLNitD APP (LLATE OFFICIAL

_MCRE1 Amv IDO wi11 % T _ Nm11 Reaional Administrator, Rec. I App. 1 X

PART N. D-APPEAL RIGHTS The seniet t y each conytng otheel scentihed m Part ti C may te oppoeted to the Appellate Officiet soentefed m that secten Any such appesi must te in writmg and must tie mooe withm 30 ceys of receipt of ttus responu Appeens must te sod'essed as appropriate to the f secutive Director for Operations or to the Secretary of tte Commissen.

U S. Nuclear Reputatory Commission. Washington. DC 20666. and shoom cieerty state on the envelope end m the lettee that at is en Appes' from en initial FOIA Decison/

sdRC FORM 464 (Port ti U.S. NUCLEAR REGULATORY COMMISSION FOIA RESPONSE CONTINUATION

,,n-Re: F0!A.89-309 APPENDIX G

RECORDS MAINTAINED AMONG PDR FILES NUMBER DATE DESCRIPTION 1.

6/21/89 Letter from J. Wiggins to E. Brown, PSCo, NH, re 11RC Region 1 Inspection No. 50-443/69-05.

Accession No. 8906280032 2.

6/26/89 Letter from G. Thomas,itHY, to NRC providing response to i

Inspection No. 50-443/09-03.

Accession No. 8907050362 l

I i

t r

l l

l 1

t

I L

L Re:

F0!A-89-309 j

i APPENDlX H l

RECORDS MAINTAINED IN THE PDR UNDEli THE AB0VE REQUEST NUMBER j

i DA1E TO FROM SUBJECT

[PAGES 1.

05/00/86 Seabrook Trainin9 36

)

Center Detailed System Text Material Steam Dump System 2.

11/00/66 Seabrook FSAR, Page 1

i 142-4(Question 7) 3.

09/12/66 Distribution G. Kann Low Power Test Program 2

PSNH Training (Question 18) 4 01/00/89 Operations Training /

1 l

Standards 5.

06/21/89 J. Calvo C. Starud Atmospheric Dump Valves 2

at Seabrook 6.

06/22/89 Recorded channel data 77 i

and off-line plots of i

natural circulation test at Seabrook, Unit 1 7.

06/22/89 Chronological Sequence 8

of Events Related to Failure of MS-PV-3011 8.

06/22/89 Seabrook Unit 1 Manual 2

Reactor Trip with

+

Complications (AIT)

(89-25) 9.

06/22/69 Seabrook Unit 1 Manual 2

ReactorTripw(ithUpdate)

Complications (AIT)(89-26)

10. 06/23/89 Data from NHY Seabrook 2

MPCS Post Mortem Report

11. 06/26/89 D.E. Moooy H.E. Kenney Main Steam Dump Valves 1

Evaluation

Re: F01A-89-309 APPENDIX H RECORDS 11AINTAINED IN THE PDR UhDER THE ABOVE REQUEF,T NUMBER (Continued)*

t DATE TO FROM SUBJECT

  1. PAGES 12.

Undated Repetitive Task Sheet 4

Process B

13. 06/27/89 A. Thadani M. Hodges Acitivities for the 1

k'eek of 6/27/89 -

7/3/89[Portionsde-leted are outstoe scopeofrequest)

14. 06/29/89 P. Gurney R. Gwir.n Basis for the Minimum 1

Pressurizer Level Trip Crtteria for the Natural l

Circulation Test 1-ST-22 i

i

15. 06/3C/69 Condenser Steam Dump 39 l

Valve Evaluation Report i

16. 06/30/89 Con. Markey L. Zech 2

i

17. Urdated Pages 2, 3, and 4 of 3

Seabrook procedure 1-ST-22, Rev. 2, with handwritten annotations i

Ret F01 A> 89-309 APPENDIX I

RECORDS PART! Ally WITHHELO NUMBER DATE DESCRIPTION 4 EXEMPTION l

1.

6/22-23/S9 Listing and tape recordings of phone calls through the NRC Operations Center regarding Event No.15933.

(

The list and tape recording of the conversation between the licensee and NRC regarding Seabrook 50.72 report on manual trip during startup test program at 1320 hours0.0153 days <br />0.367 hours <br />0.00218 weeks <br />5.0226e-4 months <br /> on 6/22/89, are being released.

The remaining recorded phone conversations are being withheld pursuant to Exemptions 5 and 7(A).

r t

+

t i

4