Responds to Deviation Noted in IE Insp Rept 50-289/80-05. Corrective Actions:Gai/Gpunc TMI Project Mgt Manual,Revision 0 & Gpunc ES-009,Revision 0 Issued to Ensure All Gai Work Is Completed Per Util Document
ML19326E054
Person / Time
Site: Crane 
Issue date: 07/16/1980
From: Herbein J
METROPOLITAN EDISON CO.
To: Brunner E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
NUDOCS 8007250504
Download: ML19326E054 (2)


Text

-. _.

fAttropotion Edison Company m

' [1 t

$ If,"

if ()[

Post Of fice B:nc 480 if f'

Middletown. Pennsylvania 17057

__r.

t 717 944 4041 1

Writer's Direct Dial Nurnber July 16, 1980 TLL 339 Office of Inspection and Enforcement Attn:

E. J. Brunner, Chief Reactor Operations and Nuclear Support Branch U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pa.

19406

Dear Sir:

Three Mile Island Nuclear Station, Unit I (T'41-1)

Operating License No. DPR-50 Docket No. 50-289 Inspection Report 50-289/80-05 This letter is in response to Inspection Report 50-289/80-05 uhich contains one apparent deviation. Attached please find our response.

Sincerely, S!gned 3. G. Herbein J. C. Herbein Vice President TMI-I JCH:DGM: hah Attachment-cc:

B. H. Crier R.11. Reid B. J. Snyder D. Dilanni

'H.

Silter J.

T.. Collins b s I

k-

    • V h

E

TLL 339 INSPECTION REPORT 50-289/80-05 Deviation:

The RRR is a three volume document that had been submitted by the licensee to NRC-URR describing the control and requirements to be imposed on Unit I restart activities. The inspectors noted that in a number of instances this document imposes requirements in addition to those found in the QA Progran and implementing procedures such as GP-1008.

The inspector identified that those additional RRR requirements vere not included or referenced in 2ny impicmenting instructiona/ procedures, including engineering tasks assigned to the licensee's architect /

engineer (three specific examples are discussed in paragraphs 4.c and 5.b of this report).

The failure to incorporate those additional requirements into implementing instructions / procedures is considered to be a deviation since the RRR is a written commitment to the NRC (289/50-05-01).

Response

The failure to incorporate the additicnal RRR requirements into implementing instructions has been corrected by the issuance of the GAI/GPU"C TMI Project Management Manual rev. O dated 4/30/80 and GPUNC ES-009 rev. O dated 7/8/80. Paragraph 2:05 of TMI PMM directs the project engineer to ensure that all CAI work is done in accordance with RRR.

CPUNC ensures same by using the Verification Checklist in ES-009.