ML19326D831

From kanterella
Jump to navigation Jump to search
Forwards IE Insp Rept 70-1201/80-06 on 800330-0404.No Noncompliance Noted
ML19326D831
Person / Time
Site: 07001201
Issue date: 05/07/1980
From: Stohr J
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To: Heer W
BABCOCK & WILCOX CO.
Shared Package
ML19326D832 List:
References
RII:WJM, NUDOCS 8007030368
Download: ML19326D831 (2)


Text

f are

/

4 UNITED STATES 8

i NUCLEAR REGULATORY COMMISSION N 'MC/

6' E

REGION 11 o

101 MARIETTA ST N.W SUITE 310o o

ATLANTA. GEORGIA 30303 In Reply Refer To MAY - 7 B80 RII:WJM 70-1201/80-06 Babcock and Wilcox Company ATTN: Mr. W. F. Heer, Manager Virginia Operations Nuclear Materials and Manufacturing Division Commercial Nuclear Fuel Plant (CNFP)

P. O. Box 800 Lynchburg, VA 24505 Gentlemen:

This refers to the inspection conducted by W. J. Millsap of this office on March 30, through April 4, 1980 of activities authorized by NRC License No.

SNM-1168 for the Commercial Nuclear Fuel Plant facility, and to the discussion of our findings held with W. F. Heer at the conclusion of the inspection.

Areas examined during the inspection and our findings are discussed in the enclosed inspection report.

Within these areas, the inspection consisted of selective examinations of procedures and representative records, interviews with personnel, and observations by the inspector.

Within the scope of this inspection, no items of noncompliance were disclosed.

We have examined actions you have taken witu regard to previously identified enforcement matters. These are discussed in the enclosed inspection report.

In accordance with Section 2.790 of the NRC's " Rules of Practice", Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room. If this report contains any information that you (or your contractor) believe to be proprietary, it is necessary that you make a written application within 20 days to this office to j

i withhold such information from public disclosure. Any such application must j

include a full statement of the reasons on the basis of which it is claimed that j

the information is proprietary, and should be prepared so that proprietary infor-nation identified in the application is contained in a separate part of the i

document. If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.

1 8007030 8d7

MAY - 71980 Babcock and Wilcox Company,

4 Should you have any questions concerning this letter, we will be glad to discuss them with you.

Sincerely,

. Philip St br, Chief Fuel Facility and Materials Safety Branch

Enclosure:

Inspection Report No. 70-1201/80-06 1

4 i

i f

t

+-

~

F

r..

,_