a s Oh 5

REOULATORY INFORMATION DISTRIBUTION CYSTEM (RIDS)

DISTRIDUTION FOR INCOMING MATERIAL 50-313 REC: REID R W ORG: WILLIAMS D 11 DOCDATE: 06/16/78 NRC AR PWR & LIGHT DATE RCVD: 06/21/7 I - DOCTYPE: LETTER NOTARIZED: NO COPIES RECEIVED

(

SUBJECT:

LTR 1 ENCL 0 FURNISHING INFO RE D L W"S NOTIFICATION OF MAY 3 & G, 1978, THAT SUBJECT FACILITY"S INCORE DETECTOR UNCERTAINTY USED IN THE PAST MAY BE TOO SMALL.

PLANT NAME: ARKANSAS -- UNIT 1 REVIEWER INITIAL:

XJM DISTRIBUTOR INITI AL:

okoo*************

DISTRIDUTION OF THIS MATERIAL IS AS FOLLOWS ***************++*

GENERAL DISTRIBUTION FOR AFTER ISSUANCE OF OPERATING ' LICENSE.

(DISTRIDUTION CODE AOO1)

FOR ACTION:

DR "u" r nRBit4 BC**LTR ONLY(7)

INTERNAL:

(EG F LF#

TR ONLY(1)

NRC PDR**LTR ONLY(1) a.TR ONLY(2)

OELDin>LTR ONLY(1 )

HANAUER**LTR ONLY(1)

CORE PERFORMANCF BR**LTR ONLY AD FOR SYS & PROJ**LTR ONI.Y ( 1 )

ENGINEERING BR**LTR ONLY(1)

REACTOR SAFETY BR**LTR ONLY(1)

PLANT SYSTEMS BR**LTR ONLY(1)

EEB*>tLTR ONLY(1)

EFFLUENT TREAT SYS**LTR ONLY(

J.

MCGOUGH**LTR ONLY(1)

EXTERNAL:

LPDR'S RUSSELLVILLE. AR**LTR ONLY(1)

TIC **LTR ONLY(1)

NSIC**LTR ONLY(1)

ACRS CAT B**LTR ONLY(16) ln h-IHIS DOCUMENT CONTAINS P00R QUAUTY PAGES s

lISTRIBUTION:

LTR 40 ENCL 0 CONTROL NBR:- 7:31700 ?OO IZE: 2P ocs******************************

THE END 3o04240 D /

g,

~

(

(

c.

~

gygy DBCKEf M CDY ARKANSAS POWER & LIGHT COMPANY POST OFFICE BOX 551 UTTLE ROCK, ARKANSAS 72203 (501)371-4000 June 16, 1978 r

4.)

1-068-8 Director of Nuclear Reactor Regulation ATTN:

Mr. R. W. Reid, Chief

[;

~

Operating Rector Branch #2

q U. 3. Nuclear Regulatory Commistion k

['l

}

Washington, D. C.

20555 VI

Subject:

Arkansas Power 6 Light Company Arkansas Nuclear One-Unit 1 Docket No. 50-313 License No. DPR-51 In-core Detector Uncertainty (File:

1510)

Gentlemen:

On May 3 and May 5 of this year B 6 W notified AP 6 L that the incore detector uncertainty used in the past may be too small.

A reinvestigation of the incore detector un-certainty by B 6 W using observed operational characteris-tics indicated to B 6 W that a larger uncertainty value should be used.

AP G L had indicated to Mr. Guy Vissing (NRC Project Manager) that per his request, we would in-form the NRC of our proposed course of action in this matter.

We have been evaluating B 6 W's new uncertainty analysis and have concluded that we have insufficient data, to determine its merits.

We have requested additional infhrmation from B 6 W regarding their work.

Further evaluation by us of their work will have to await their response.

In the interim, the auditional uncertainties upon incore de-tector measurements of quadrar.t tilt and imbalance recommended by B 6 W have been included in the plant computer TECALM sub-routine (the program which generates alarms based on tilt and imbalance).

This was accomplished by Software Change Request l

Mx)3s-MEMBER MfDOLE SOLTTH UTILITIES SYSTEM

r-(

1-068-8 ~

Juns 16, 1978 4.

4 No. SEL-1-006-3.

Also, changes to the Power Operation Pro-cedure, OP 1102.04, and procedure OP 1103.17 for hand cal-culations using the. backup incore system have been made which include the new uncertainty valves.

Very truly yours, Daniel 11. Williams Manager, Licensing DiiW:0C:nh J