Q M ct.! 1 M ARKANSAS POWER & IJGHT COMPANY POST OFFICE DOX 551 UTTLE ROCK. ARKAPSAS 72203 (501) 371-4000 O f, [$. ' $.' E [3 f( ['FP "I
Lu
.:g JL NDC 2-6919 NAY Td gg
?
Bechtel Power Corporation,
Aggt;3g3 IO f R f LIC!il C0' San Francisco Power Davision TECH. t. a~-
7" VICts P. O. Box 3965 San Francisco, California 94119 Attention:
bir. E. II. Smith Project Engineer
Subject:
Arkansas Nuclear One-Unit 2 Computer Aids Used by Bechtel on ANO-2 (File:
bl-2001-B1)
Re f:
Telecon between E.11. Smith 6 Rick Lane, 5/17/78 Gentlemen:
As determined by the reference above, David Saunders, an AP6L Production Flechanical Engineer will arrive at Bechtel during mid-morning ilay 22, 1978.
Fir. Saunders has indicated he would like to consider the following topics concerning the computer aids used at Bechtel:
1)
What types of des.,n and analysis require or at least utilize a computer code (for example:
pipe flexibility, hanger stress, heat t ransfer, et c.)7
- 2) hhat is the nature of the programs used, in particular: type of input, type of output, algorithms used? (There is a special interest in your programs blE101, htE632, htE604, CE901.)
3)
What is the availability of the programs Bechtel uses? Flay we purchase them from you? from some other source? are they solely proprietary?
4). What special proceduret are required to qualify computer aids with the NRC or other regulatory agencies?
5)
What special procedures are required to qualify computer aids within Bechtcl?
6)
What is the extent of the~ data base on the ANO-2 project? What types of reports can be generated?
Is the data-ba s handler in-house or purchased?
Can we obtain the data base and associated programs?
8004 23 o 6G2 MCMot.H MtOOLE GOUTH UTtL8iiES SvST EM
I
('
-(
Mr. E. II. Smith
-2.
May 19, 1978 NDC'2-6919
- 7).llow is.the requirement for. development of a new or maintenance of an old computer aid recognized?
Is there a central group performing the development and maintenance function or is this done by the group using the aid? What svenues of communication are there concerning computer use between groups? departments?
8)
What peculiar hardware / software requirements have been recognized?
(for exampic:
flat-bed or drum plotters, graphics CI(T's, special compilers)
Any people you could introduce or materials you can provide will be greatly appreciated.
Very truly yours, s
k
\\ \\ d.)
s, Rick D. Lane Manager, Mechanical Engineering RDL:DS:dr cc:
Mr. J. W. Anderson Mr. G. II. Miller Mr. N. A. Moore Mr. D. N. Dennet t Mr. D. J. Stoker i
i i
i l
l l
I I
l i