Submits Proposed Revision to Tech Spec 3.3 Re Reactor Bldg Cooling Sys Heat Removal Capability Under post-accident Conditions
ML19326C122
Person / Time
Site: Arkansas Nuclear 
Issue date: 06/03/1977
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To: Desiree Davis
Office of Nuclear Reactor Regulation
References
1-067-5, 1-67-5, NUDOCS 8004210472
Download: ML19326C122 (3)


Text

.

NRC F;nu 195 u.s. NUCLEAR CEGULATCGY CoMMISSl!N '

!OKET NUM23R is-m

,A.

50-3/.3 NRC DISTRif"JTION poa Pa.lT 50 DOCKET MATERIAL TJ:

FROM:

oats or occuMENT Arkansas Powcr & Light Company 6/3/77 Mr. D. K. Davis Little Rock, Arkansas DATE REcEivEo 6/7/77 J. D. Phillips ELETTER O NOTOR12 E O PROP (NPUT FORM NUMDER OF COPIES RECEIVEo SbRicNAL RUNCLASSIFIE D

-mm l S / G AJtW

_QcoPY DESCRIPTION ENCLOSURE D

Amdt. to OL/ change to tech specs...

g concerning the cooling systems at the O l g

plant........

{U i

t N ET ~ MOW

( 2-P )

R PLANT FAME:

Arkansas Unit No.

ACKNOWLEDGED RJL SAFETY FOR ACTION /INFORMATION Fwinn ASSIG"ED AD:

Ansicw n An.

[J @ jQLLCJIIEFe

/.Jat ut.: ( 6) nRANCp r"vTrv.

[JJ01ECT PANAGER; Sect s d e.v PROJECT MANAGER:

[MC. ASST. :

Otyp S LIC. ASST. :

INTERNAL DISTRIBUTION 2 r.G FILE' )

SYSTEMS SAFETY PLANT SYSTEMS SITE SAFCTY &

/ gu rust HEINE"AN TEDESCO ENVIRO A"ALYSIS 7.I & E (2)

SCHROEDER BENAROYA DENTON & Mf'T T rn

/ OELD TATNAR GOSSICK & STAFF ENGINEERING IPPOLITO ENVIRO TECH.

MIPC MACA_RRY KIRIRQOD ERNST CASE B032AK BALLARD

/ HANAUER SIHWEIL OPERATING REACTORS SPANGLER O RLESS PAWLICKI STELLO SITE TECH.

PROJECT MANAGEMENT REACTOR SAFETY OPERATING TECH.

GAMMILL BOYD ROSS

/

EISElaIUT STEPP P. COLLINS NOVAK

/

SHAO HULMAN HOUSTON ROS7. TOC 2Y

/. BAER PE'"ERSON CHECK

./

MELTZ

/. BinMR SITE ANALYSIS CRIMES VOLLIER HELTEMES AT & I BUNC,H SKOVHOLT SALTZMAN

/ J. COLLINS RUTETRG l KRECV.R EXTERNAL DISTRIBUTION CONTROL NUMBE R g LPDR: kautdmN.6 6 JATuLAB; BE00KilAVEILNAT LAR.

t gT_IC_:

REG V.IE ULRIKSON (ORNL)

/p -

4 NSIC:

LA PDR I

A.SLB:.

CONSULTANTS:

ZACRS H, Cvs um.m=_orr p c a-.- 6 g

N LC FCRM 1g3 (7 76) soo4 elo V72 p -

b*

,p H ELPIN G BUILO ARKANSAS ARK ANS AS POWER G LIGHT COMPANY PO sox 551 LITTLE AOCK. A AK ANSAS 72203 (5011371-4000 June 3,1977 Regulatory Docket File d '  %,

'b O

9I 1-067-5 H

w1 Director of Nuclear Reactor Regulation g

ATTN: Mr. D. K. Davis, Acting Chief Mp Operating Reactors Branch #2 U. S. Nuclear Regulatory Commission b

T{yf Washington, D. C.

20555 N

Subject:

Arkansas Nuclear One-Unit Docket No. 50-313 License No. DPR-51 Proposed Technical Specifications (File:

1511.1)

Gentlemen:

Technical Specification 3.3.4(A) requires that in order to attain and maintain criticality that all four reactor building cooling fans and associated cooling units be operable. If compliance with this speci-fication is not maintained, Technical Specification 3.3.6 requires that we proceed to a hot shutdown within 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />.

Section 6.3.3 of the Arkansas Nuclear One-Unit 1 Final Safety Analysis Report presents the design evaluation of the Reactor Building Cooling System. This evaluation shows that with two cooling units inoperable, the heat rewval capability of the cooling system under post-accident conditions is not degraded sufficiently to allow reactor building pressure to increase above the design value.

It also shows that a single failure may still be experienced and no degradation will occur to the point of not maintaining the reactor building pressure below the design pressure under post accident conditions.

We propose to revise Technical Specification 3.3.4(A) to read as follows:

Two reactor building spray pumps and their associated spray nozzle header and four reactor building emergency cooling fans and associ-ated cooling units with the exception that one cooling fan may be out of service for a period not to exceed seven days.

Due to the situation with which we are now faced, i.e.,

one cooling fan inoperable and no spare available within the 36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br />, we request that e

t T A X p.4 YING. IN VE S TC A QWN E D 3

MEMF3E A MIDOLE SOU TH U TILITIE S S Y S TE M L

i j

-n.

w

, Mr. D. K. Davis 2-Juns 3,1977

)

. 1-06,7-5 ^

1 l

this proposed specification be expedited. Based on the fact that the basis for this specification comes from the Draft Technical Specifications for ANO-2 proposed by the NRC Staff and our FSAR analysis and system design supports the proposed specification, we do not forsee any problems in this.

Very truly yours,

/

'l WW/

J. D. Phillips

/

Senior Vice PresiMent -

JDP:tw 4

5 e

i

._ 4