O ATTACHENT TO LICENSE AENDMENT NO.'27 FACILITY OPCRATING LICENSE ~NO. DPR-51 DOCKET NO. 50-313 i
Accomplish page changes to the Appendix A portion of the Technical Specifications as noted below. The changed areas on the revised pages are identified by a marginal line.
Remove Existing Page Add Revised Page 66e 66e 66f 66f i,
b d
)
i 8 004180 7M
3.14 IlYDR0 GEN PURCE SYSTEM Applicability i
Applies to the operating status of the hydrogen purge system.
l Objective To ensure that the hydrogen purge system will perfom within acceptable lavcis of efficiency and reliability.
Specification 3.14.1 Two independent circuits of the hydrogen purge system shall be operabic whenever reactor building integrity is required with the following perfomance capabilities:
a.
The results of the in-place cold DOP and halogenated hydrocarbon tests at design ficws (+ 10'4) on HEPA filters and charcoal ad-
~
sorber banks shall.how > 90's DOP removal and > 99'; halogensted
~
~
. hy drocarben removal.
b.
Tne results of laboratory carbon sample analysis shall show
> 90*3 radioactive methyl iodide removal at a velocity within
~+ 205 of system design, 0.15'to 0.5 mg/m# inlet methyl iodide concentration, > 70'. R. H. and > 100F.
c.
Fans shall be shown to operate within 10*4 design flow.
d.
The pressure drcp across the combined HEPA filters and charcoal adsorber banks shall be less than 16 inches of water at system design flow rate (; 10's).
Each system inlet heater shall be shown to operate at rated e.
power.
f.
Hydrogen concentration instruments shall be operable.
If t' e requirerents of S;:ecification 3.14.1 cannot be met, 3.14.2 h
the system shall be returned to coerable status within 30 days or the reactor shall be placed in the hot shutdown condition within the.next.6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
Bases lhe hydrogen purge system is designed to operate as necessary to lit the hydrogen concentration in the reactor building following an acciuent.
Amendment No. If. 27 66n