ML19326C084

From kanterella
Jump to navigation Jump to search
Amend 28 to License DPR-51,modifying Tech Specs pressure- Temp Limit Curves for Hydrostatic Test,Normal Heatup & Cooldown Per B&W Analysis of Surveillance Capsule ANI-E
ML19326C084
Person / Time
Site: Arkansas Nuclear 
Issue date: 09/14/1977
From: Desiree Davis
Office of Nuclear Reactor Regulation
To:
Shared Package
ML19326C083 List:
References
NUDOCS 8004180751
Download: ML19326C084 (3)


Text

,

s 4

f UNITED STATES 3'

NUCLEAR REGULATORY COMMISSsON f

.' #' I, h WASHINGTON, D. C. 20066

(

s.

- [

ARKANSAS POWER & LIGHT COMPANY DOCKET NO. 50-313 ARKANSAS NUCLEAR ONE - UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 28 License No. DPR-51 1.

The Nuclear Regulatory Comission (the Comission) has found that:

A.

The application for amendment by Arkansas Power & Light Company (the licensee) dated July 8, 1977, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Comission's rules and regulations set forth in 10 CFR Chapter I; B.

The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.

There is reasonable assurance (1) that the activities authorized by this amendment can be conducted without i

endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.

The issuance of this amendment will not be inimical to the comon defense and security or to the health and safety of the public; E.

The issuance of this amendment is in accordance with 10 CFR Part 51 of the Comission's regulations and all applicable requirements have been satisfied.

8 004180 7pf

. 2.

Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and Paragraph 2.c(2) of Facility Operating License No. DPR-51 is hereby amended to read as follows:

(2) Technical Specifications The Technical Specifications contained in Appendices A and B, as revised through Amendment No. 28, are hereby incorporated in the license. The licensee shall operate the facility in accordance with the Technical Specifications.

3.

This license amendment is effective as of the date of its issuance.

FOR THE NUCLEAR RECT LATORY COMMISSION l

'N

)

L-N Don K. Davis, Acting Chief Operating Reactors Branch #2 Division of Operating Reactors

~

Attachment:

Changes to the Technical Specifications Date of Issuance:

September 14, 1977 e

O

ATTACHMENT TO LICENSE AMENDMENT NO. 28 FACILITY OPERATING LICENSE NO. DPR-51 DOCKET NO. 50-313 Change the Appendix A portion of the Technical Specifications as noted below. The changed areas on the revised pages are identified by marginal lines.

Remove Pages Insert Pages 18 18 18a 19 19 20 20 20a (new) 20b(new) 20c(new)

Figures 3.1.2-1 and 3.1.2-2 21 21 31 31 32 32*

  • There was no change on this page.

It is included as a matter of convenience in' updating the Technical Specifications.