Concurs w/pre-notice Issuance on Exemption Request & Suggests SER State That Davis-Besse Would Have Same Effect on Metal Specimens as AR Unit One
ML19326B815
Person / Time
Site: Arkansas Nuclear, Davis Besse  
Issue date: 10/07/1976
From: Davis L
NRC OFFICE OF THE EXECUTIVE LEGAL DIRECTOR (OELD)
To: Converse B
NRC COMMISSION (OCM)
Shared Package
ML19326B809 List:
References
NUDOCS 8004180564
Download: ML19326B815 (1)


Text

~

,5

.s October 7,1976 ~

Note to Bill Converse APPENDIX H EXEMPTION FOR REACTOR VESSEL SURVEILLANCE SPECIMENS 1.

I concur with the issuance of a pre-notice on this exemption request.

2.

A reading of the Applicant's incoming safety evaluation shows a shortcoming that shculd be remedied by our analysis:

the SER

/

should describe why the operation of Davis-Besse would have the

/

same effect on the metal specimen that could be expected if they I

were inserted in ANO, Unit 1.

This would appear to be especially critical where, as in these embrittlement tests, heat and method

/

of operation of the plant would have such a large effect on the metal.

ho

' ('Dow Davis T..

L.

Attorney, OELD tgt,'S h 31 i A T,d

!" A d

?

L O'.FL )

> e,. w-w

,. d I J Ob 3,,s i

)

l 8 0041.8 OEd f J