LER 78-022/03L-0:on 780820,fluid in Hydraulic Shock Suppressor Did Not Cover Supply Line to Valve Body.Caused by Incorrect Suppressor Installation.Suppressor re-oriented
ML19326B433
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/30/1978
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19326B433 (1)
LER 78-021/03L-0:on 780818,leak Found in B Reactor Coolant Pump Area.Caused by High Pressure Seal Cavity Pressure Sensing Line Leak.Leak to Be Repaired in Next Shutdown
ML19326B429
Person / Time
Site: Arkansas Nuclear 
Issue date: 08/30/1978
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19326B429 (1)
LER 78-020/03L-0:on 780817,solenoid Valve SV 7807,supplying Control Air to VSF-9 Discharge Damper,Failed.Caused by Valve Defect.Valve Replaced