ML19326B328

From kanterella
Jump to navigation Jump to search
Forwards AO 50-313/74-04
Date released: 12/06/2019 Download: ML19326B328


AO 50-313/74-04:on 740706,makeup Pump P-36A Stopped Due to Excessive Vibration.Cause Appears Bearing Oriented.Pump Will Be Inspected & Repaired as Required
ML19326B333
Person / Time
Site: Arkansas Nuclear 
Issue date: 07/08/1974
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19326B333 (1)
AO 50-313/74-04:on 740706,primary Makeup Pump P-36A Radial Bearing Failed.Caused by Dislodged Mating Pins.Mating Pins Lengthened from 1/2 to 1 Inch & anti-rotation Pin in Sleeve Bearing Lengthened from 3/8 to 3/4 Inches
ML19326B330
Person / Time
Site: Arkansas Nuclear 
Issue date: 07/16/1974
From: Reuter D
ARKANSAS POWER & LIGHT CO.
To:
References
Download: ML19326B330 (3)
Forwards AO 50-313/74-04
ML19326B327
Person / Time
Site: Arkansas Nuclear 
Issue date: 07/16/1974
From: Phillips J
ARKANSAS POWER & LIGHT CO.
To: OLEARY J F
US ATOMIC ENERGY COMMISSION (AEC)
References
Download: ML19326B327 (2)