ML19326A387

From kanterella
Jump to navigation Jump to search
Forwards Investigation Rept 44-2-288 on 720314 for Info. Noncompliance Noted:Eight Plates in Improperly Heat Treated Condition Used in Units for Facilities.W/O Encl
ML19326A387
Person / Time
Site: Davis Besse 
Issue date: 04/03/1972
From: Engelken R
US ATOMIC ENERGY COMMISSION (AEC)
To:
References
44-2-288, NUDOCS 8002030191
Download: ML19326A387 (1)


Text

e s

O 8*,

UNITED STATES

/* }*

  • 't ATOMIC ENERGY COMMISSION F'

k' l,

l l 'I WASHINGTON. D.C. 20S45

-/hu APR 3 D72 D

~

R. C DeYoung, Assistant Director for PWR's, DaL R. R. Maccary,t.ssistant Director for Engineering, DRS IWESTICATICII RZPORT ALLI:G2D IRRZGUL'd(ITIES AT TIIE EA1;COCI; & UILCOX CGIPAW yorwarded for information is a report of an investigation of alleged irregularities at the Babcock & Uilcox Compaay (:K!.;)

relative to the fabrication of steam benerators for the luncho Seco and Davis-desse facilities. The allegations were made by a former E&W employee. The investigation was carried out by representatives of the Division of Compliance and the Division of Inspection, in response to iaformation supplied by the office of Congressman Jack F. Itemp.

As may be noted, the use of eight plates in an improperly heat treated condition in units for the two facilities was confirmed

  • y the investigation. lio other deficiencies were identified.

O This matter was discussed with you previously, resulting in

(

letters from the Division of neactor Licensing to the respective licensees. We would be pleased to assist in the evaluation of the licensees' responses; however, we plan no further action with respect to shop inspection of the units in question.

If you have questions on this matter, please advise.

O[t.H.Jagelkenb Mgth.a~

Assistant Director for Inspection and Enforcemenc Division of Compliance l

A/3 TC!T33EL*$

Jaclosure:

C C-1 I;is Rpt 44-2-288 dtd 3/14/72 Q"

n.t +,3 cc:w/ encl.

p. ///y/.y S

-iisamsp=e '

LDLow, CO

-s Ornblich, Jr, CO ph'.....

c.;g CO:I, III & V

,. g L =~ '$86 r.,..,

f) 8 0 02 0 3 0\\M mi v

c e

Paulus e.

W