.t Docket Nuc 99901164/89 01 Octobst 13. 1989 Mr. Timothy E. Conver, President Electronic Resources Division Whittaker Corporation 1955 N. Surveyor Avenue Simi Valley, California 93063
Dear Mr. Conver:
This letter addresses the inspection of your facility at Simi Valley, California conducted by Mr. Richard C. Wilson of this office on June 20 22, 1989, and the discussions of his findings with you and your staf f at the conclusion of the L
inspection.
The inspection was conducted as the result of an allegation concerning nuclear safety-related thermocouple system components supplied for use in nuclear power plants. Areas examined during the NRC inspection and our findings are discussed in the enclosed report. This inspection cor.sisted of an examination of procedures and representative records, interviews with personnel, and t
observations by the inspector.
Within the scope of this inspection, we found no instance where you failed to meet NRC requirements.
However, discrepancies in your manufacturing l
controls as described in paragraph E.3 of the enclosed inspection report provide the basis for the NRC to continue to monitor actions by you and l
Combustion Engineering, Incorporated to improve your quality prcgram.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
l Sincerely, Origin:l s:;ned by E. William Brc:h L
E. William Brach, Chief Vender Inspection Branch Division of Reactor Inspection l
and Safeguard l
Office of Nuclear Reactor Regulation L
Enclosures:
Appendix A-Inspection Report 99901164/89 01 j
Appendix B. Inspection Report 99900401/89 01 DISTRIBUTION:
>' RIDS: Code IE:09e VIB Reading DRIS Reading BGrimes EBrach'
^
UPetapovs RWilson(2)
CBerlinger
[WHITTAKER CORP LETTER]
OFC
- VID:DRIS
- 5C:VIb:DRl5
- BC:ylB;DRI5 NAME :RCWilson:nr UPota s
- EWB h
- ..............:3............:..............:..............:.............
DATE
- 09/2R/89
- 09/4/89
- 09/4 /89 0FFICIAL RECORD COPY 89102g % h
{gT g
&m Ul
-