ML19325D167

From kanterella
Jump to navigation Jump to search
Application for Renewal of QA Program Approval for Radioactive Matl package:0172.Fee Paid
ML19325D167
Person / Time
Site: 07100172
Issue date: 10/09/1989
From: Gaumer G
EMPIRE STEEL CASTINGS, INC.
To: Macdonald C
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NUDOCS 8910190098
Download: ML19325D167 (23)


Text

'i_

j V;,

7/- W7v i

EW4tB STEEL CASTINGS, INC.

.. ke,'

^

]."e"'

1 Ess

R sitet cAstmas

.P.O. Box 139 e Reading, Pa. 19603 0139 p

OCT161983 r D

k I O

' Tclophone 215 921-8101 mit stcrion UD:KETCitgg ll Charles E. Mac Donald, Chief

, 19 Transportation Branch s

Division of Safeguards'and Transportation, NMSS L

United States Nuclear Regulatory Commisr, ion Washington, D.C.

20555 l

Subject:

Renewal Quality Assurance Program for Radioactive Material Packages. No. 0172 l

Dear,

Mr. Mac Donald, 1

Inclosed 3 copies for your review of Empire Steel Castings Inc. Quality Assurance Program for Radioactive Material Packt.ges. Renewal fee of $150.00 inclosed.

Sincerely, Gene R. Gaumer k.LsJ kr W

  • I s

r; m.

  • Wh i

b4

' m -

6 4.4 2.L e.__.

a m ittnr...........

L hcc h tjo., J-)pj, !!_,,,,, _,,,

?.m urst,...

Foctccory.f/ft)________

.sog3___________

\\

, n re of Ica _..& kf[7)l L Datu Chtck Re:*d._ j ~ l/ 89101900988,?d88$7+ l Y' [ 28/44-/--- PDR ADOCK C "A


- / W - '

PDC C ~~~~ - - ~ - -- - - Plant location:' 1501 Frush Valley Road, Laureldale, Pa.19605 p

o.~.. + EMPIRE STEEL CASTINGS, INC. Post Office Box 139 s ') Reading PA.19603 ( ;i L 4 4 9 g 1 p 4 4 9 q o 9 - QUALITY ASSURANCE REQUIREMENTS - FOR~ RADIOACTIVE SHIPPING PACKAGES (10CTR PART 71) i... O + e 4 k m

t,:r i 1. Organization 2 i 1 i. The final responasbility for the Quality Assurance Program for Part 71 Requirements rests with Empire Steel-Castings, Inc., Frush Valley Road, Laureldale, PA 19603. Design and . fabrication of radioactive material shipping packages shall not be conducted under this Quality Assurance Program. The following organizations 2. Organizational Chart President - Edward J. Crowley Quality Assurance Manager - Gene R. Gaumer Quality Assurance Operations - Forrest Schmeck Applications Manager - Forrest Schmeck 3. The Radiation Safety Officer is responsible Ecr overall administration of the program, training and certification, document control and auditing. (Gene R. Gaumer Forrest Schmeck) 4.~ The Radiographers are responsible for hand 1*ing, storing, shipping, inspection, test operating status and record keeping. (Gene Gaumer, Forrest Schmeck, Clarence Schoffsta11, Jr., and' Ben Randazzo.) 5. Quality Assurance Program The management of Empira Steel Castings, Inc., Frush. Valley + Road, Laureldale, Pa 19603, establishes and implements this Quality Assurance Program. Training for all Q A. functions, prior to engagement in these functions,-is required according to written procedures. Q.A. Program revisions will be made according to written procedures with management approval. The Q.A. Program will ensure that all defined 0.A. procedures, engineering procedures, and specific provisions of the package design approval are satisfied. The 0.A. Program will L emphasize control of the characteristics.of the package which are critical to safear. l ra s-*m-w + -- ,m

e i~ 6 . Procedure.for handling of Radioactive Packages A All Radioactive Packages will be surveyed and checked-A. for damage upon receipt. All Radioactive Packages will be brought to the.X-Ray B. Department upon receipt of package. The Radioactive Package will be stored in exposure t C. areas #1 or #2. See Layout. Drawing Torm I.. Source will be changed immediately by Radiographers. D. ' Package will be checked for damage and se,aled. E. The proper tags and labels will be placed on package } ~ 'T. and type source, curie strength, and survey reading. Transportation Instructions (Form II) will be used G. for shipment of Radioactive' Packages. The Radioactive. Package will be held in X-Ray Department H..until notified of transportation of shipment. The following check list will be used for receiving, storage and shipping of Radioactive Packages (Form III) t' I. All personnel will have instruction in Radiation Safety J. before handling Radioactive Packages. All documents on Radioactive Packages will be kept K. on file for a period of two (2) years.- l I b a k r

i i ^ *- '7 Tha Radicticn S3foty OffiOCr chill cscure thct cl1 r:dicsstive material shipping packages are' designed and manufactured (: under a Quality Assurance Program approved by the Nuclear Regulatory Commission for all packages designed or fabricated 4 after 1 July 1978. This requirement can be satisfied by V s receiving a certification to this effect from th,e manufacturer. 8. Document Control j All documents related to a specific shipping package will be controlled through the use of written procedures. All document changes will be performed according to writted procedures approved by management. 9. The Radiation Safety Officer shall insure that all QA functions l are conducted in accordance with the latest applicable changes to these documents. 10. Handling Storage and Shipping l Written safety procedures concerning the hahdiing, storage and shipping of packages for certain:special form radioactive i material will be followed. Shipments will not be made unless all tests, certifications, acceptances, and final inspections have been completed. Work instructions will be provided for handling, storage and shipping operations. Refer to Transportation Instructions. 11. Radiography personnel shall perform the critical handling, storage and shipping operations. Refer to #6. L 12. Inspection, Test and Operating Status l Inspection, test and operating status of packages for certain L special form radioactive material will be indicated and controlled by written procedures. Status will be indicated by_ tag, label,, marking or log entry. Status of nonconforming parts or packages will be positively maintained by written -procedures. Refer to #6. 13. Radiography-personnel shall perform the regulatory required l inspections and tests in accordance with written procedures. The Radiation Safety Officer shall ensure that these functions l .are performed. (Refer to #6, Form II. 14 Quality Assuranco Records Records of package approvals (including references and drawings), inspections, tests, operating logs, audit results, personnel training and qualifications and records of shipment will be maintained. Descriptions of equipment and written procedures will also be maintained. Refer to #6. .. ~..

C 15. - These records will be maintained in accordance with written f::. procedures.. The records will be identifiable and retrievable. A list of these records, with their storage locations, will be maintained by the. Radiation Safety Officer. Refer to #6. 16. Audits A' Established schedules of' audits of the Quality Assurance Program will be performed using written checklists. Results of audits will be maintained'and reported to management. Audit reports will be evaluated and deficient areas L corrected. The audits will be dppendent on the safety l significance of the activity being audited, but each activity will be audited at least once per year. Audit reports will be maintained as part of the quality assurance records. Members of the' audit team shall have no responsibility in [ the activity being audited. p,r % g 4 6 f t 4 k i e 0 0 I 0

ms.. ((..' DiPIRE STEEL CA$11NGS, INC. ' ^ Nt Omee tou 139 - . e-Reading, PA 19603 s 4 l I ?- s 9 Transportation Instruction 4 4 ? g e 4 4 4 f

EMPIRE STEEL CASTINGS. INC. J-- 1 Post 'Omco Box 139 -J' Rea'lng, PA 19603 o ' (- t PART I RECEIVING RADIOACTIVE MATERIAL NOTES: 1. A package of radioactive material must f be. accepted.from the carrier at the time it is delivered. (10CTR20,205(a)(1)) 2. if a package of radioactive material is to-be held at the carrier's terminal, it must be picked up expeditiously upon receipt of s notification ~from the carrier of its arrival. (10CTR20.205(a)(2)) 1 1. Upon receipt of a' package of radioactive material, survey the exterior surfaces of the package to insure.That the radiation levels do not exceed 200 milliroentgens per hour.- (10CTR20.205(c)) l t 2. Survey three feet from the exterior : surfaces of the package t to insure that radiation levels do not exceed 10 milliroentgens. per hour. (10CTR20,205(c)) 3. For packages containing radioactive material in normal form (i.e. not in special form), make contamination, wipe tests of ( - the exterior surfaces of the package.. Count these wipes to insure.that contamination levels do not exceed 0.01 i microcuries per 100 square centimeters. (10CTR20.205(b)). 4. Record the results of these surveys on the Receiving Report. If any of the above limits are exceeded, notify the Radiation Safety Officer. (10CTR20.401(b)) 5. Record on the Receiving Report the source, model number, r' I serial number, isotope, activity, shipping container model L number and serial number. p 6. Inspect the package for any evidence of physical damage. Record the result of this inspection on the Receiving Report. 7. Torward a copy'of the Receiving Report to the Radiation I ' l Safety Officer. l. l l-l I ~

f EMPIRE STEEL' CASTINGS, INC.. f Post Office Box 139 - Reading. PA 19603 i PART II SHIPPING RADIOACTIVE MATERIAL j h SUBPNRT A SHIPMENT OF RADIOGRAPHIC SOURCES L 1. Insure. that the soure:e is secured in the proper shielded j storage position in the shipping container. { 2. Attach a security seal with an identification mark to the package closure. (49CFR173.393(b)) 3. If the shipping containar is to be packaged inside a crate or other outer packaging, the outer packaging must be-strong.,enough to withstand the normal conditions of transport. 3 i: Place the chipping container in the outer package.with i sufficient blocking to prevent shifting during transportation, E t (49CFR173.25) 4. Survey the package at the surface and at three feet from the surface to determine the proper radioactive ~ shipping i labels to be applied to the package. Use the criteria of Table II.1.-(49CFR172_.403) I Surface' 3' Feet IIAD10ACTIVil-ifillTl! I /,* r e s ,' d \\ os N l 4 ( .=.i....... 0.5mR/hr None 's RA010ACIWE s : :. E / i .s I / sF / %,/ RADIOACT3,VE-YELLOlf 11 's kv 's O \\ 50mR/hr 1.0mR/hr 's Ill C E [l? D ?s p,) i 3!y )',/ f N s> s/ l<AD1OACTQ'li-Ylil,Lotf 111 N s s.40iGR E q" / )- N:::. 200mR/hr 10mR/hr 7;hj l / N s s I sN'// o v l.

  • N-*F y

-*'*e+- +w

  • e-6.-

f c, ~; Post.Cface Box 139 Q - Reading, PA 19603. PART II-(otntinued) i

  • i',~

((Y SUBPART A c5. -Properly: complete 1two-shipping labelsLindicating the 3 contents:(19ZIridium, 60 obalt, etc.), the. number of curies i C and?the1 Transport Index (maximum radiation level measured Dat threerfect from the surface of the package; used on Yellow II-and-Yellow'III labelstenly). (49CFR172.403(g)) ' 4 6. Insure that'any oAo u.2pping labels have been removed-from 'the package. Apply the two properly. completed radicactive shipping labels to two opposite sides:of the< package. (49CFR172.403(f)) 1 c 7.- Mark tha outside of the pac.kage with the proper shipping name (Radioactive haterial, Special Form, n.o.s.) if not already marked.: (L,CTR172.300) y j ? 8. If a shipping-container is packaged inside a crate or other . packaging mark the outside package,"Inside Container in i (Fill:in the' blank space with 9' Accordance with the! appropriate DOT Specification NumberLof Type B Certificate Number)nand the words " TYPE B" or " TYPE A" if applicable. ~ (49CTR172.310; 49CTR173.393a) a '9. ' Perform 1a radioactive' contamination w3pe test; of the shipping 4,. microcuries per 100 square centimeters.- (49CFR173.397; package and insure that the wipe test.does not, exceed 0.001 49CTR173.393(n)(9) 1'. Properly complete the shipping papers.indicat'ing: O Proper shipping name.(i.e. Radioactive Material, Special a.- - Form,.n.o.s.) 192 Iridium, 60 Cobalt) b. Name of-Radionuclide-(i.e. c. Physical or chemical form (or Special Form) d. Activity of Source (expressed in curies or millicuries) Category of Label applied (i.e. Radioactive Yellow III) s -f. Transport Index . g. USHRC Identification Number cn? DOT Specification Number i.e. USNRC: USA /9032/B or DOT-7A) h. For export shipments, IAEA Identification Number (i.e. IAEA: USA /9032/B) (49CTR172.203(d)) y e n -y e---.--- y w a ,w

g' EMPIRE STEEL CASTINGS, INC.' ' Posi Omce Box 139 ? o E '~,; f,_ Reading. PA 19603 l i. l 1 } 2- 'PART II (continued)~ SUBPART A; _l i.: ~ Shipper's-Certification: q "This is!to certify that the,above'. named materials are properly classified, described, packaged, marked and- -labeled and.are in' proper' condition-for transport according'to-the applicable regulations of the Department of Transoortation.,"' (49CTR172.204(a))

Notes:

1. -For air shipments, the following shipper's. ~~ l certification may be used:~ "I hereby certify that the' contents of this consignment are fully.and accurately _. described above by proper. shipping nanie and'are classified, packed',-marked and labeled and are in proper. o contiition for carriage.by air according to applicable-4 national governmental regulations".- (49CFR172.204(c))- I,c 2. For air shipments, the package must be' labeled with a CARGO AIRCRAFT ONLY" label and the shipping ~- papers must state:~ (49CFR172 WO2(b))- "THIS' SHIPMENT IS:WITHIN'THE: LIMITATIONS PRESCRIBED'FOR CARGO-ONLY AIRCRAFT" (49CTR172.204(c)) t i G 9 N i i 4 e B -e, -~mw -,,w,,-s- --u----

g jl EMPJRE STEEL / CASTINGS, INC. - l j l' Post Omco Box 139

p. (.

F. Reading. PA 19603 + 4 ' PART II SHIPMENT OF.i:AbI0 ACTIVE MATERIAL ' .In. .) SUBPART'B-. SHIPMENT OF; EMPTY DEPLETED URANIUM SHIELDED CONTAINERS AND COLLIMATORS L l 1. If the container is to be packaged inside a-crate or other outer packaging,.the outer packaging must be strong enough to withstand the normal conditions.of transportation. Place the container-in the outer package with sufficient, blocking i to prevent shifting during transportation. V 2. Mark the outside of the outer shipping package: " RADIOACTIVE - MATERIAL - LSA, n.o.s."

(49CFR173.392(c)(8); 49CFR172.300) 3.

Perform a radioactive contamination wipe test of the shipping package and insure that.the wipe test does not exceed 0.001 i microcuries per 100 square centimeters. (49CTR173.397;.49CFR173.393 (n)(9)) 4. Survey the package at the surface and at three feet from the surface to determine the proper radioactive shipping labels to be' applied to the package. Y ^ a.L If the' surface radiation level. is less than 0.5 milliroentgens ~ ~ iper hour and there is no measurable radiation-level at threeEfeet from the surface, no label is required. Mark the outside'of the package'with the statement:1 " Exempt from' specification packaging, marking and labeling, and exempt from the provisions of 49CFR173.393 per 49CFR173.391(c).. Exempt from the requirements of 49CFR Part 175 per 49CFR175.10(a)(6)." (49CFR173.391(c) S 4 9CFR175.10(a)(G)) 4 Properly complete the shipping papers indicating:

(1)-Proper shipping name (Radioactive Material LSA, n.o.s.)

(2) Name of Radionuclide (Depleted Uranium) p (3) Physical or Chemical Form (Solid Metal) a (4) Activity (in curies or millicuries) ,.m,

d-pp . EMPIRE STEEL' CASTINGS, INC.

. f a-C ip Post' Office Box 139

.I h i' { 9., Reading. PA 19603~ .4 o ti .: PART III -(continued) { @/i ~ l4 L J, .SUBPART'_B_ LL (5)zThe: Statements" Exempt from' specification packaging:- N I marking and labeling. and exempt from1the provisions of 49CTR173'.393 y 49CFR173'.391(c). Exempt ~from the requirements e 3CFRLPart 175 per 49CFR175.10(a)(6);" l ? (49CTR172.203(d))- (6) Shipper's Cortification: ^ '"This is to_ certify that the.above named materials are properly-classified, described,1 packaged, marked and labeled and are in proper condition for transport according to.the applicable regulation 3 of the-t Depa.'tment'of Transportation." . (49CTR172.204(a)) NOTES: 1. For Air Shipments, the following shipper's certification may be usedr. "Ifhereby' certify that the contents of this consignment are fully and accurately described above by proper shipping name and are classified,. t + l packed, marked and labeled and are in proper-

I ~

condition for carriage ~by air accordi,ng/to 7 applicable national governmental regulations." 3 ~(49CFR172.204(c)) 2. For" Air Shipments, theLfollowing statement 'must appear: "This' shipment is withinnthe limitations 3r prescribed for passenger aircraft in accordance jE L with 49CFR175.10(a)(6). (49CFR172.204(c)) n b. If the: surface radiation level exceeds 0.5 milliroentgens p per hour, or if there is a; measurable radiation level at J three feet from the surface, use the criteria of Table II.1 to determine the proper radioactive shipping L -labels to be_ applied to the package. L L Properly co.mplete-the shipping papers indicating: L '4 (1) Proper shipping name (radioactive material, LSA,n.o.s.) m l (2) Name of Radionuclide (Depleted' Uranium) j (3) Physical or Chemical Form (Solid Metal) y ,C j h

)}[. */[ 4* EMPIRE STEEI/ CASTINGS INC. l tr { Post Office Box 139

j pt [ '. f *,

Reading. PA.19603 : j p . PART .(continued) k 15J SUBPART'B s + >= X (4)1 ' Activity (in curies or millicuries) J 1 (5): Category off Label Applied. (i.e. Radioactive Yellow 1II) j -(6) : Transport Index 'l -.( 7 )l USNRC Identification Number or. DOT Specification NumberK(i.e. USNRC USA /9032/B'or DOT-7A) t (8) For Export Shipments, IAEA Identification Number (i.e. IAEA USA /9032/D) (49CFR172.203(d))- (9) Shipper's' Certification' I "This is to certify that'the above named materials ace' properly classified, described,l packaged, marked E and-labeled and are in' proper! condition for transport according to the. applicable regulations of the' Department: of Transportation." (49CFR173.204(a)) .c ~ \\._ r NOTES:

1. : For Air. Shipments, the following shipper's b

certification may be used: [ "I hereby certify that the contents of J l this consignment are fully and, accurately l described above by proper shipping name 4 and are classified, packed, marked and labeled and are in proper condition for-carriage.by' air according to applicable l-national governmental; regulations."- ( 49C FR17 2 '. 2 04 (c ) ) ' 2. For Air Shipments, the package must be labeled with a " CARGO AIRCRAFT ONLY" u k label and the shipping papers must etate: (49CFR172.402(b)) This shipment is within the limitations prescribed for cargo-only ai* craft." (4SCFR173.204(c)) 3 L

~ ~

q.. s ; y i. t

' EMPIRE STEElfCASTINGS, INC.. p Post Omce Box 139 ,J 4: . Reading. PA ~ ~ 19603 2 [J PART II-SUBPART C. SHIPMENT OF EMPTY: LEAD SHIELDED' CONTAINERS'- 1.3 ' Insure that the container does not contain a' radioactive l Source. - Insure that the' container interals are securely closed or 2. contains no.radioactiva contaminations. (49CFR173.29(c)) i 3.- Perform a: radioactive contamination wipe test of the outside l of the container and insure that the wipe: test >does;not i exceed O.001 microcuries'per 100 square centimeters.- f -(49CTR173.397)' 4. = Survey. the external surface of the. container to-insurn.that-the radiation levels do not exceed-0.5 milliroentgens per - hour. (49CFR173.29(e)) l Ir.sure that any old' shipping labbis have been removed from 5. B the package. Attach an " EMPTY" label to the package. g L (49CFR173.29(e)) i.- '~ l' 1 l L g r D 1' i I ( I L 'l '.

^ ~ n.s," .. - 4 - EMPIRE STEEL CASTINCS, INC. [ 4 P - Post Ofnce Box 139 -i

  • )-

Reading, P4 19603 - l{ c? ART'III CARRYING RADIOACTIVE MATERIAL' r' 1.;_ Insure'that the' vehicle used.is in good condition:and carries tne normal' complement of safety equipment including: radiation area signs, a length-of rope,' spare tire, fire' extinguisher, a-set of. vehicle tools and a set of' flares. -The glove compartment shall contain the registration. certificate and an t; operating: flashlight. Additionally, the operator must-have a calibrated and operable survey meter and be wearing a film badge >and-dosimeter. 2. Insure that she container is properly packaged, marked and labeled and the proper shipping papers are completed it. .accordance with the instructions of Part II. 3. ' place the radiocctive material container in the vehicle. - Secure the container'against movement in the vehicle. (49CTR177.834) 4. Survey the driver's compartment to insure that the r.adiation level does not exceed 2 milliroentgens per hour. (49CFR173.393(j)(4)) 5. If the vehicle.is transporting a package bearing a " RADIOACTIVE YELLOW III" label, the vehicle must be placarded on all four sides with~a " RADIOACTIVE"' placard. (49CFR172.504) Note:- Operation _of a vehicle whi6h is required to be placarded requires compliance with the Federal Motor Carrier Safety' Regulations (49CFR390-397) 6. Conolete the radioactive material transport. checklist. For?.ard a. completed copy to the Radiation Safety.0fficer upon completion of the' carriage. 7. - If the vehicle becomes disabled on the road, do not leave the vehicle unguarded when going for help. A message-for help may be sent by a passing motorist 6r the police be enlisted to guard the vehicle. .8.. Should any' kind of accident occur, make an immediate radiation survey to see where, if at all, the radiation levels are higher than normal. If any abnormal radiation areas exist, keep all persons out of them:and get police assistance, if . possible. If radioactive sources have escaped from'their containers,. notify the Radiation Safety Officer. Do not-leave the scene without assuring that someone responsiblo (such as police) will keep people away from radiation areas. 4 e -e s e w-yr y---* ,w w w

5 s I'* EMPIRE STEEL' CASTINGS, INC. U h " "'..... .3 Post Office Box 139 Reading. PA 19603. ,.3 ..PART-III (continued) i1 ~ ,' 9. Collect information' pertinent _'to the accident, such as names ofLwitnesses,' names-of people involved,' names of police, -license numbers, circumstances of-the accident. Call the' Radiation Safety Officer promptly givf.ng him as much .information as possible about the condition of~the radioactive j sources. - 10. -If a source. should escape: from:its container, the vehicle. operator shouldmake no attempt.-to restore.the.sourca_by himself, bot'he should wait for assistance from the-Radiation Safety Officer. e 5 6 6 e 1 ba 1 I ~l 1 t 4 5-(.

3 Nk i e c., ~ n,;,.' 9 if f .t

a ___;

,I i ,F. .'I 41 - FORMS i I-GENERAL LAYOUT & STORAGE II' RADIATION SHIPMENT C0rio, IR192 s 1 - III RADIOACTIVE PACKAGE CHECKLIST i .IV AUDIT CHECKLIST Ic l-:. J l 1 -. -.i, a 1 i i + y 1 j i T :l l ? !I !1 S a

~, n, m, - 4g :9 . + - - o, w ~

:'.i'; >

H+' =- r i e 7'.,.lll.y l ..y*' + . sQ: a '. ' _-f-d

g L-e W

.M., . GENERAL' LAYOUT- -FORM I< =l ' ' c.; 'EXPOSUREAREAS' 1. 4 a' 4. SOURCES'S: -A,P,C,D ,'l e 1 3 -I P f EXPOSURETAREA #1: EXPOSURE AREA'#'!' 'C.-C060>'300 ci-A.. - IR 192 100- ci; Model 520 .tiodel 660' yn > 'B. C060 50ciy m ~ D.IR ~ 1921100 '. ci Model 6601 Model 4j6 j e

Alsot.for storage of Also for' storage of-J.

' Radioactive shipping-Radioactive shipping-packages packages W 4 ..t i t ...s.. t'. W m h_, i 6., A s a d. i,gg, _7 m l CLgeNG

  • r!. ~ -

,i aped., 4, '?.. gg ano gg ' ' *se amo e.m emp ee I l s. ' ' pgM O$ (., - S-h s g .,p.. atuRE4REW \\ gg$j

  1. pocu M s

y :.. ygg#. 2 s .s: m r i ess' t s t m Co BA L.T ..",s C w eistu m A'.' )k. g' '. ~5 ~ f.i. 4 g s .l p. i a k .P =, g = k e e d k ' .i \\ = 'N V hv A 4 M W J f f / / f J LW l " f. f 5 l 5 5 l l ? 5 l l - A 4 9 ,,**.4 1. b e, e. m c==- a =w m-..--w e.<-*-

q_ s;7- .c q g.-.. e . - + b' b -- Y.

1..i.* -

F.ORM II ,. DiPIRE STEEL CASTINGS ( INC. '! t 4 s F.C. Box:139 Reading PA 19603= it j ,J Radiation Shipment 1 . Danger:., + s Shippers' Certification -1 1 -l 192-IR ei ] ~ Survey Readings

  • j surface

- 1 Meter R x ~ J ' "Thisais to certify that the above. named' materials are properly; classified, described,-packaged, marked. and. . labeled,:and are.in-proper condition for transport according:to the applicable regulations of the 1.. .c Department'of Transportation." (49CFR:172.204(a)) .1 Date RSO 1 l I i o D 4 1 o l o m -r ww <~s-o r,v. <-,,,a- +n . = ,s ,e .a--- u v - - --m


orw.

-<--e .s ,w

7qi j 4 FORM II gj = ' ' '.. f - - . EMPIRE'STZEL CASTINGS, INC. --P. 0.. Box 139.- Reading PA 19603 1 - e Danger:. Radiation Shipment Shippers Certification CO. 0 6 eg q \\; L-i; Survey Readings Surface 1 Meter \\ l "Thisis te Nortify that the above named materials are properly classified, described,; packaged, marked, and j p ' labeled, and are in proper condition for'transoort i n according to the applicable regulations of the-Department of Transportation." (49CTR 172.204(a)) 4. . l Date RSO-9 + r j 1 -: ? 'F_ i .-4

p.' <, 1 g

-.; f

/ ef. FORM-III RADIOACTIVE PACKAGE-CHECK LIST '1.: 'Date Received-E?.. Condition of. Package-

3.

. Survey of Package at Surface-Survey of: P3ckage at 1-Meter 4.- Package-Stored in_ Area

  1. 1-
  2. 2 (circle.one) no 5.1, Type Source 6.

Curie Strength ~ 7 '. Condition..of Package Before Shipping-8'.-- . Type Source Shipped 9. Curie Strength of Source Shipped

10.

-Proper Tags and Label's in Place

11.

~ Package Shipped '(Truck,. air) - 12. Package Received by Manufacturer (Date) Person performing check list (Signature) 5

' 3l j:7*. 8 ..c h- ._ FORM IV AUDIT CHECK LIST-4 Date 9 1. Radioactive Packages being received and stored in proper area upon arrival.. 2. Package check for damage. e 3. Surveys taken. -4. Source changed. Package check for: damage and proper tags.and L

5..

label attached before shipment. 6.. Package shipped by proper transportation. g l j-7. Reports and documents on Radioactive Packages L being maintained.

  • t Auditor L-1 i

I: i x y k l '. L .}}