Text
{{#Wiki_filter:( R D .. ! > , , y ,.s t -
+ , , , , 4 ' .' , '
, iQ, .l SGTB8JPJ - ' P'?? ,
' J1-0192 1 - ;
' NOV 0 91989 ! ' ' - < , L g. Pacific Nuclear Systems, Inc. f
.;
Y. ATTN: 'Dr. C. J. Temus ' - - -M Technical Director ' , e
- 1
'1010 South 336th Street ! i Federal Way, WA' 98003 { ' , ' Gentlemen:. , This refers to the quality assurance inspection of fabrication activities at) - i Nuclear Packaging Systems, Inc., TRUPACT-II Assembly Facility (TAF), by.
M0ssrs. J. P. Jankovich and J. R. Cook, and Ms. C. T. Haney of the U.S.
,i Nuclear Regulatory Commission (NRC) and by Mr. B...W. Brown of Idaho National
6 Engineering Laboratory, EG8G, on September 26-28, 1989.
t < Areas examined during the inspection and our findings are discussed in the- e enclosed report. Eight items of nonconformance with NRC requirements were iden- tified during the inspection. The nonconformances are listed in item 4 of the a inspection report. With regard to the nonconformances, please provide within 30
days from the date of this letter: (a)'awrittenexplanationorstatementde- ' ' ' scribing corrective actions taken or planned, the dates when corrective actions 3 'will be completed, and measures taken to 3reclude recurrence; and (b) a repott ." onLan independent review of all radiograpls taken as of the date of the inspec- tion. , , In accordance with 10 CFR Section 2.790 of the Commission's regulations, a copy of this letter.and the enclosed inspection report will be placed-in the NRC
' Public Document Room. Should you have any questions about this inspection, we will be pleased to dis- ! cuss them with you. Sincerely, , Origir? *taned by H GARLL.a. MACDONALD l' Charles E. MacDonald, Chief f i l Transportation Branch Division of Safeguards and Transportation, NMSS 1 Reviewed
j - .E. Krauss, NMSS 4 , " y Enclosure: ' 7 Inspection Report- Q 710192/89-06 gp
. [# Distribution: 'O - RBurnett JJankovich DKasun BWBrown. INEL - ? H ' - GMcCorkle CHaney JLieberman. OE VLM111er, GPA s 7 . P E ' CMacDonald STreby, 0GC ABeach, RIV RMcFarland, EEG/NM ' ' ' JCook , 8911160206 891109 P ' '6 ' NRC? F/C3 PDR SH0 NMSS/SGTB r/f PDR ADocK 07100192 ' C PNV
_ N - 0FC:
- 5GTB
- 5GTW
- 5GTB n
.'
e@ SGTBM1'V ' 0 ET -
- JCod
- CMacDona5d:
[[..
- NAME
- Jankovich/lg4:,C"aney
-
4 -- ' . c- .. _, , _ . }}