l i
Docket No. 50 423 S13391
{
j l
e j
g.
t i
i
\\
t F
Millstone Nuclear Power Station, Unit No. 3 Proposed Revision to Technical Specifications Containment Hydrogen Monitors I
t 1
1 l-November 1989 l
8911160153 891102
{DR ADOCK05000,g3 l
5
I INSTRUMENTATION
' ACCIDENT MONITORING INSTRUMENTATION LIMITING CONDITION FOR OPERATION 3.3.3.6 The accident monitoring instrumentation channels shown in Table 3.310 shall be OPERABLE.
APPLICABILITY: MODES 1, 2, and 3.
ACTION:
a.
With the number of OPERABLE accident monitoring instrumentaticn channels except the containment area high range radiation monitor, and the containment hydrogen monitor less than the Total Number cf l
Channels shown in Table 3.3-10, restore the inoperable channel (s) to OPERABLE status within 7 days, or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in at least HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
b.
With the number of OPERABLE accident monitoring instrumentation channels except the containment area-high range radiation monitor, and the containment hydrogen monitor less than the Minimum Channels l
OPERABLE requirements of Table 3.3-10, restore the inoperable channel (s) to OPERABLE status within 48 hours5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in at least HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, c.
With the number of OPERABLE channels for the containment area-high range radiation monitor less than required by either the total or the Minimum Channels OPERABLE requirements, initiate an alternate method of monitoring the appropriate parameter (s), within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />, and either restore the inoperable channel (s) to OPERABLE status within 7 days or prepare and submit a Special Report to the Commis-sion, pursuant to Specification 6.9.2, within 14 days that provides actions taken, cause of the inoperability, and the plans and sched-ule for restoring the channels to OPERABLE status.
d.
With the number of OPERABLE channels for the containment hydrogen l
monitors less than the total number of channels shown in Table 3.3-10, restore the inoperable channel to OPERABLE status within 30 days or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in at least HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />. With the l
number of operable channels for the containment hydrogen monitors less than the minimum channels OPERABLE requirement of Table 3.3-10, l
restore the inoperable channel (s) to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in at least HOT SHUTDOWN within the following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />, e.
The provisions of Specification 3.0.4 are not applicable.
SURVEllLANCE RE0VIREMENTS 4.3.3.6 Each accident monitoring instrumentation channel shall be demon-strated OPERABLE by performance of the CHANNEL CHECK and CHANNEL CALIBRATION l
at the frequencies shown in Table 4.3-7.
MILLSTONE - UNIT 3 3/4 3-59
g t
CONTAINMENT SYSTEMS 3/e.6.4 COMBUSTIBLE GAS CONTROL HYDROGEN MONITORS llMITING CONDITION FOR OPERATION 3.6.4.1 Two independent containitent hydrogen monitors shall be OPERABLE.
APPLICABILITY: MODES 1, 2, and 3 ACTION:
a.
With one hydrogen monitor inoperable, restore the inoperable monitor to OPERABLE status within 30 days or be in at least HOT STANDBY w the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in at least HOT SHUTDOWN within the following 6
- hours, b.
With both hydrogen monitors inoperable, restore at least one monitor to OPERABLE status within 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> or be in at least HOT STANDBY within the next 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> and in at least HOT SHUTDOWN within the l
following 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br />.
c.
The provisions of Specification 3.0.4 are not applicable.
l SVRVEILLANCE RE0VIREMENTS 4.6.4.1 Each hydrogen monitor shall be demonstrated OPERABLE by the performance of a CHANNEL CHECK at least once por 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br />, an ANALOG CHANNEL OPERATIONAL TEST at least once per 31 days, and at least once per 92 days on a STAGGERED TEST BASIS by performing a CHANNEL CALIBRATION using sample gas containing:
a.
One volume percent hydrogen, balance nitrogen, and b.
Four volume percent hydrogen, balance nitrogen, i
1 l
l l
l MILLSTONE - UNIT 3 3/4 6-35