ML19324A082

From kanterella
Jump to navigation Jump to search
Forwards LER 80-066/03L-0
Date released: 12/04/2019 Download: ML19324A082


LER 80-066/03L-0:on 800516,containment Isolation Valves FCV1-7,-14,-25 & -32 Determined Not Protected Against Steam Jet Resulting from Crack in Loop 1 Main Steam Riser.Caused by Design Error.Action Initiated to Install Proper Supports
ML19324A086
Person / Time
Site: Sequoyah 
Issue date: 06/13/1980
From: Swearingen J
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19324A086 (2)
Forwards LER 80-066/03L-0
ML19324A081
Person / Time
Site: Sequoyah 
Issue date: 06/13/1980
From: Calhoun J
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19324A081 (1)