LER 80-055/01T-0:on 800531,w/Unit 1 in Cold Shutdown,Insp of Mechanical Snubbers Was Performed & 45 Out of 61 Snubbers Were Found Locked Up.Caused by Internal Corrosion.Snubbers Replaced
ML19324A078
Person / Time
Site: Hatch 
Issue date: 06/11/1980
From:
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19324A078 (2)
Forwards LER 80-055/01T-0
ML19324A075
Person / Time
Site: Hatch 
Issue date: 06/11/1980
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19324A075 (1)