CONNECTICUT YANKEC ATOMIC POWER COMPANY j'
[\\
7 f
H ADDAM NECK PLANT RR = 1. DOX 127E. EAST HAMPTON, CONN. 06424 June 5, 1980 Docket No. 50-213 U. S. Nuclear Regulatory Commission Region 1 Office of Inspection and Enforcement 631 vark Avenue King of Prussia, Pennsylvania 19406 Attn:
Mr. Boyce Grier, Director
Dear Mr. Grier:
This correspondence forwards a Special Report pursuant to Technical i
Specifications, Section 6.9.3.d, Steam Generator Tube Report.
Please
{
be informed that during eddy current testing of Steam Generators #1 1
and #2, two tubes in Steam Generator #2 exceeded the plugging limit i
of 50% wall degradation.
The defective tubes were Row 40, Column 24 and Row 41, Column 24.
Additional inspections were performed in accordance with Technical Specification requirements and no further defects were discovered.
j I
t very truly yours, f
W&
Richard H. Graves Station Superinte.ident RilG:JPD/jhb o
USNRC, c/o Document Management Branch, Washington, D. C.
ec:
i I.
1 5
8006.180 J %