PntL (psurgjo,,

UNITED STATES

=

o NUCLEAR REGULATORY COMMISSION g

r E WASHINGTON, D. C. 20555

%, * *... p*i MAY 211380 t

A FCTC: RHO 71-0384 New England Nuclear Corporation ATTN: Mr. Ermes DeMaria 601 Treble Cove Road North Billerica, MA 01862 Gentlemen:

We have evaluated your Quality Assurance Program dated April 15, 1980 submitted to satisfy the requirements of 10 CFR 571.51.

Our review indicates that additional information is required to satisfy the applicable requirements of Appendix E to 10 CFR Part 71.

Please address the enclosed request for additional information and submit seven copies of the revised program within 60 days following receipt of this letter.

If you have any questions regarding this request, please feel free to contact Mr. Jim Conway at (301) 492-7741.

Sincerely, L

Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS

Enclosure:

Request for Additional Information 800612e q OT

NEW ENGLAND NUCLEAR CORPORATION (71-0384)

Request for Additional Information 1.

In Figure 1-1, show the lines which identify the reporting responsibilities of each individual or group.

2.

Identify and describe the QA/QC functions performed by the Transportation Safety Committee or delegated to other organizations providing controls to assure appro-priate elements of Appendix E will be implemented.

3.

Provide a statement that management (i.e., above or outside the QA organization) regularly assesses the scope, status, implementation, and effectiveness of the QA program to assure that the program is adequate and complies with 10 CFR Part 71 Appendix E criteria.

4.

Provide a statement that an indoctrination and training program-is established such that:

(1) Personnel responsible for performing quality-related activities are instructed as to the purpose, scope, and implementation of the QA manuals, instructions, and procedures.

(2) Personnel performing quality-affecting activities are trained and qualified in the principles and techniques of the activity being performed.

(3) The scope, the objective, and the method of implementing the indoctrination and training program are documented.

(4) Proficiency of personnel performing quality-affecting activities is main-tained by retraining, reexamining, and/or recertifying.

5.

Provide a statement that identification of materials and parts important to the function of safety-related systems and components can be traced to the appropriate documentation such as drawings, specifications, purchase orders, manufacturing and inspection documents, deviation reports, and physical and chemical mill test reports.

6.

Provide a statement that correct identification of materials, parts, and components is verified and documented prior to release for fabrication, assembling, and instal-lation.

7.

Provide a statement that special processes such as welding, heat treating, non-destructive testing, and cleaning are procedurally controlled.

8.

Provide a statement that inspection personnel are independent from the individuals performing the activity being. inspected.

9.

Provide a statement that measuring and test instruments are calibrated at specified intervals based on the required accuracy, purpose, degree of usage, stability characteristics, and other conditions affecting the measurement.

l 10. Provide a statement that reference and transfer standards are traceable to nation-ally recognized standards; or, where national standards do not exist, provisions are established to document the basis for calibration.

11. Provide a statement that special handling, preservation, storage, cleaning, packaging, and shipping requirements are established and accomplished by quali-fied individuals in accordance with predetermined work and inspection instructions.
12. Provide a statement that departure, arrival time, and destination of a package will be established and monitored to a degree consistent with the safe transporta-tion of the package.
13. Provide a statement that the application and removal of inspection and welding s tampsr and status indicators such as tags, markings, labels, and stamps are procedurally controlled.
14. Provide a statement that bypassing of required inspections, tests, and other critical operations is procedurally controlled.
15. Provide a statement that the status of nonconforming, inoperative, or malfunction-ing packages or components is identified to prevent inadvertent use.
16. Provide a statement that a list of the required records and their storage locations will be maintained.

l l