ML19323H296

From kanterella
Jump to navigation Jump to search
Forwards LER 80-042/03L-0
Date released: 12/03/2019 Download: ML19323H296


LER 80-042/03L:on 800510,during Performance of Local Leak Rate Test,Combined Leakage for All Penetrations Tested to Date Exceeded Combined Allowable Leakage.Caused by Buildup on Valve Preventing Good Seal.Valve Seats Will Be Relapped
ML19323H297
Person / Time
Site: Davis Besse 
Issue date: 06/08/1980
From: Rohrer E
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19323H297 (2)
Forwards LER 80-042/03L-0
ML19323H295
Person / Time
Site: Davis Besse 
Issue date: 06/06/1980
From: Murray T
TOLEDO EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML19323H295 (1)