Responds to IE Bulletin 80-06, Engineered Safety Feature (ESF) Reset Controls. Util Interprets Bulletin as Applying Only to PWRs & BWRs & Not to Htgrs.Ltr Constitutes Closing Ref for 90-day Reporting Requirement
ML19323G521
Person / Time
Site: Fort Saint Vrain Xcel Energy icon.png
Issue date: 03/27/1980
From: Warembourg K
PUBLIC SERVICE CO. OF COLORADO
To: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
IEB-80-06, IEB-80-6, NUDOCS 8006040043
Download: ML19323G521 (1)


Text

.

bec to DAC:ADM:

CENTRAL FILES l

l PDR:HQ

?!?]

Public service company or c oq y ea f)1 16805 Weld County Road 191/2, Platteville, Cof

, NSIC

,i M

March 27, 1980 Fort St. Vrain Unit No. 1 P-80063 Mr. Karl V. Seyfrit, Director Region IV Cffice of Inspection & Enforcement Nsclear Regulatory Commission s

611 Ryan Plaza Drive Suite 1000 Arling! - Texas 76012

Subject:

IE Bulletin 80-06

Dear Mr. Seyfrit:

In reviewing the referenced bulletin, it was determined that the action required applies only to PWR's and BWR's and not to HTGR's.

If you concur with this determination, consider this letter as the closing reference for the 90 day reporting requirement.

Very truly yours, h~

Don Warembourg Manager, Nuclear oduction DW/cis cc:

Nuclear Regulatory Commission Office of Inspection & Enforcement Division of Reactor Operatio is Inspection Washington, D.C.

20555 G.

APR-3 9 4)hk 8006040 0 9