ML19323G401

From kanterella
Jump to navigation Jump to search
Ro:During Wk of 800512,no Surface Contamination Monitoring Was Performed.Operator in Charge Was Assigned to Work at Another Facility.No Procedures Exist for Assigning Responsibility.Procedures Have Been Revised
ML19323G401
Person / Time
Site: 05000083
Issue date: 05/23/1980
From: Diaz N
FLORIDA, UNIV. OF, GAINESVILLE, FL
To:
References
NUDOCS 8006020365
Download: ML19323G401 (1)


Text

_ - _

(

NUCLEAR FACILITIES DIVISION CouEGE UNIVERSITY OF FLORIDA e-oF DEPARTMENT oF NUCLEAR ENGINEERING SCIENCES A.

f 102 NUCLEAR REACTOR BUILDING ENGINEERING GAINEsVILLE, FLORIDA 32611 AREA CODE 904 PHONE 392-1429 May 23, 1980 Office of Nuclear Reactor Regulation Division of Operating Reactors Nuclear Regulatory Comission Washington, D.C.

20545 RE:

Facility License R-56, Docket 50-83 Gentlemen:

We are hereby reporting a potential violation of our Technical Speci-fications, as follows:

1.

Regulations:

our Tech Specs require that the Facility be operated and maintained according to written procedures.

Standard Operating Procedures UFTR-SOP-D.4 " Radiation Protection Weekly Survey", para-graph II. A. requires that surface contamination in the (reactor) cell be monitored by taking random swipes and recording the results on a weekly basis.

2.

Finding:

contrary to this requirement, no surface contamination monitoring was done for the week of May 12, 1980.

The survey was not performed because the operator in charge was assigned to work at another facility for the week and no established procedure for for-mally assigning the responsibility to another technician exists.

3.

Actions to Prevent Recurrence: operators with fixed assigned res-sponsibilities are to have their responsibility re-assigned in writ-ing when they are not going to be in the reactor facility for any one week.

Please let us know if further information is required.

Sincerely yours, NilsJ.hiaz Professor and Director of Nuclear Facilities NRC, Region II, UFTR Subcommittee, Reactor Operators c.c.

NILS J. DIAZ, DIRECTOR (904)392-1406 i

8006020.% S S

' " * " " ' ' " ' ' " " " " " * " ' " " ^ * ' ' * * ' " ' ' " "