A Form NRC418 U.S. NUCLEAR REcVLAToRY COMMIS$loN

(

CERTIFICATE OF COMPLIANCE 10 CFR For Radioactive Materials Packages 1.f a) Certificate Numcer 1.(b) Revision No.

1.(c) Package ide9tification No.

1.(d) Pages No. 1.(e) Total No. Pages 0010 4

USA /c030/q( )

1 9

2. PRE AMBLE 2.tal This ce tificate is issued to satisfy Sections 173.393a.173.394,173.395. and 173.396 of the Deoartment of Transportation Hazardous Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-104 and 146-19-100 of the Cepartment of Transportation Dangerous Cargoes Regulations (46 CFR 146-143), as amended.

2.(b)

The packaging and centents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 7 3, "Packagirig of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions /*

2.(c)

This certificate does not relieve the consignor fror9 comcliance with any reauirement of the regulations of the U.S. Departraent of Transoortation or other apolicaD!e regulatory agencies, including the government of any country thr3 ugh or into which the package will to transport 9d.

3. This certificate is issued on the basis of a safety analysis report of the package design or acplication-3.(a)

Prepared by (Name and address):

3.(b)

Title and identification of report or application:

Technical Operations, Inc.

Technical Operations, Inc. application dated Northwest Industrial Park March 10,1975, as supplemented.

Burlington, MA 01803 1

3.(c)

Docket No.

71-9039

4. CONDITIONS Tnis certificate is conditional upon the fulfilling of the requirements of Subpart O of 10 CFR 71, as applicable, and the conditions specified in item 5 below.
5. Description of Packaging and Autmorized Contents. Model Numeer, Fissile C: ass, Other Conditions, and

References:

(a) Packaging 4

(1) Model No.: 715 (2) Description A protective overpack for radiographic devices. The overpack consists of an MS-27683-2,18-gage steel drum; 14-gage clamp closure ring fastened by a bolt; 1.5 inches of Mil-I-2781 or tiil-2819 high temperature insulation; and a molded rubberized hair filler material. Overall dimensions of the over-pack are approximately 15.5-inch diameter by 24-inch high. Maximum weight including contents is 105 pounds.

(3) Drawings The rauiographic devices, as secondary packaging authorized for use in the overpack are constructed in accordance with the following Technical Operations, Inc. Drawing Nos.:

Model No.

Drawino Nos.

533 053301, Rev. B 616 061699, Rev. 0 644 D64400, Rev. I 713 C71301, Rev. 0 053301, Rev. B N3

_=

Page 2 - Certificate No. 9039 - Revision No. 4 - Docket No. 71-9039 5.

(b) Contents (1) Type and form of material Iridium-192 as sealed sources that meet the requirements of special form as defined in 571.4(o) of 10 CFR Part 71.

(2) Maximum quantity of material per package (1) 120 curies contained in the Model No. 533, flodel No. 644 or Model No. 713 radiographic device.

(ii) 240 curies contained in the Model No. 616 radiographic device.

6.

Source assemblies for use in this packaging are limited to those assemblies as identified in Technical Operations, Inc. Drawing No. C42400, Rev. F, Sheet 2, and Sheet 3 of 3.

7.

Separate molded filters shall be used for each model type radiographic device to ensure a snug fit within the overpack.

8.

Nameplates shall be fabricated of materials capable of resisting the fire test of 10 CFR Part 71 and maintaining their legibility.

9.

The packaging authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR 571.12(b).

10.

Expiration date: August 31, 1980.

REFERENCES Technical Operations, Inc. application dated March 10, 1975.

Supplements dated: April 11, 1975 and November 16, 1977.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION M fL Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety MAY 2 0 360 Date:

l h

s