ML19323F862
| ML19323F862 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 08/20/1979 |
| From: | Cunningham M, Chon Davis EG&G IDAHO, INC., EG&G, INC., NRC OFFICE OF NUCLEAR REGULATORY RESEARCH (RES) |
| To: | EG&G IDAHO, INC., EG&G, INC. |
| References | |
| TASK-TF, TASK-TMR NUDOCS 8005290557 | |
| Download: ML19323F862 (1) | |
Text
- _ _ _ _ _ _ _ _ _ _ _ _ _ _____.
D 66 6 Idaho, Inc.
MEMO 0F CONVERSATION FCAu E040-Mt e n, e.rry e
C' 8* 00VIS 8/20/79 PERSON CALLING.
DATE EG&G Idaho, Inc./IflEL
- 30 cm REPAESENTING.
TIME FERSON CALLED:
liark Cunningnam PHONE NUMBER flRC REPRESENTING.
CITv.
A. C. Peterson Clarification of TMI Sensitivity SUBJECT.
T. R. Charl ton ii. E. Ti l ler, DOE-ID Study J. A. Dearien L. J. Ybarrondo C. A. Dobbe P. H.
Vanaer Hyde o_
c_
t4++onokor nor_in Fi le 2.0 Mark confimed that the TMI sensitivity study designated as D-3 in Tong's letter should be run with one pump in each loop tripped at 73 minutes.
The calculation should be run to at least 100 minutes to see if this chance would sicnificantly alter the accident.
If the results are similar to tne base case, the calculation need not be run very far cast 100 rain utes.
e
'((1 4lM S;GNATURE iCONTiNUE ON REVERSE SIDE)
B 0052 9 0557 p