ML19323F254

From kanterella
Jump to navigation Jump to search
Forwards LER 80-073/03L-0
Date released: 12/03/2019 Download: ML19323F254


LER 80-073/03L-0:on 800425,while Performing Surveillance on Primary Containment Hydrogen Recombiner Sys,B Recombiner Failed to Operate.Cause Unknown.Combiner Tested & Proven Operable
ML19323F262
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 05/20/1980
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323F262 (2)
Forwards LER 80-073/03L-0
ML19323F253
Person / Time
Site: Hatch Southern Nuclear icon.png
Issue date: 05/20/1980
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323F253 (1)