ML19323D945

From kanterella
Jump to navigation Jump to search
Forwards Updated LER 78-019/01X-1
Date released: 12/03/2019 Download: ML19323D945


Updated LER 78-019/01X-1:on 780804,B&W Discovered That Weld Filler Wire Atypical of Submerged Arc Weld Filler Wires Specified,Was Unknowingly Mixed by Supplier.Pressure/Temp Curves Revised Then Later Reverted to Original Curves
ML19323D950
Person / Time
Site: Arkansas Nuclear 
Issue date: 05/21/1980
From: Shively C
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19323D950 (1)
Forwards Updated LER 78-019/01X-1
ML19323D944
Person / Time
Site: Arkansas Nuclear 
Issue date: 05/21/1980
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: SEYFRIT K V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML19323D944 (1)