Submits Recommendations for One Entry Into Reactor Bldg in Atmosphere of Kr-85 & Deficient Oxygen Based on Uncertain Schedule for Cleanup
ML19323D315
Person / Time
Site: Crane 
Issue date: 04/21/1980
From: Kalman G, Knapp P, Murphy T
NRC - NRC THREE MILE ISLAND TASK FORCE
To: Jay Collins
NRC - NRC THREE MILE ISLAND TASK FORCE
References
NUDOCS 8005210426
Download: ML19323D315 (2)


Text

..

Distribution:

i TMI Program Office /HQ NRR r/f I

TMI Site r/f Central File hklhj f oa DR B. Snyder J. T. Collins i

MEMORANDUM FOR: J. T. Collins, Deputy Program Manager, 1MI Program Office l

FROM:

T. Murphy Task Force i

P. Knapp, Task Force l

G. Kalman, Task Force J. Wigginton, Task Force M. Shanbaky, Task Force

SUBJECT:

REACTOR BUILDING ENTRY, NRC STAFF REC 0ff4ENDATI0ti

Reference:

a.

NRC letter, NRC/TMI-80-048, from J. T. Collins to R. C. Arnold, dated March 25, 1980 t

b.

Met-Ed letter. TLL 166, from G. K. Hovey to J. T. Collins, dated April 8,1980 c.

Met-Ed letter. TLL 185 from G. K. Hovey to l

J. T. Collins, dated April 15, 1980 On March 21, 1980, the licensee requested permission from the tiRC to enter theTHIUnit2ReactorBuilding(RB).

The NRC staff has been following the licensee's preparations to er.ter the l

RB for several months. An NRC staff task force convened at TMI on l

March ll,1980, to specifically review the hazards associated with the entry j

and to evaluate the benefit of the entry versus the anticipated risk to the i

participants. The task force's recomendat6ons and concerns relative to I

the RB entry were forwarded to the licensee in Referenee a.

The licensee was unable to show that the RB atmosphere could support life in the event of respiratory equipment failure and permission to enter the RB was denied.

l The licensee's response to the task force's recomendations and concerns i

I is contained in Reference b.

Reference c. describes the results of a licensee

~

RB atmosphere sampling program which demonstrated that there are no hazardous concentrations of toxic gases in the RB atmosphere and that the RB oxygen level is sufficient to sustain life. The RB oxygen concentration was reported by the licensee to be 12.8% (normal 02 level is 20%). This relatively low 02 level is hazardous but not life threatening. The licensee's contingency plan provides for timely rescue of an incapacitated or injured j

entry team member.

I The licensee's responses and the results of the atmosphere sampling program were reviewed by each amber of the task force and were found acceptable.

i Additionally, all coments generated by the NRC staff following review of i

the entry procedure have been adequately resolved by the licensee. Several t

2005 e 10 / 24 l

i OFFICE >

SURNAME >

j DATE >

~ec % 3+ nm seem n2=

o.._.-._,._.,,,_,,,,.,

1 I

J. T. Collins 2

l full dress practice entries into the Unit 1 RB were witnessed by the NRC staff and no significant problems were identified.

I Based on the information presented above, the NRC staff recomends that the licensee's request to enter the Unit II RB be approved. Approval is recomended for one entry.

The staff concluded that entry into the RB in a krypton 85 and oxygen l

deficient environment is significantly more hazardous than an entry following clean-up of the RB atmosphere. However, in view of the uncertain schedule for RB clean-up, the staff concurs with the licensee that the i

. benefits derived by an entry at this time outweigh the postulated r sks.

y-George Kalman cc: