Text
__
{
m nacog'o o
UNITED STATES
+$ } 3 e([,j NUCLEAR REGULATORY COMMISSION n -i " /, [r REGION IV 0,
611 RYAN PLAZA oRIVE, SUITE 1000
%, ' \\/
,e ARLINGTON, TEXAS 76012 2 2 FEB 1380 Docket No. 99900400/79-03 The Babcock & Wilcox Company Nuclear Power Generation Division Attn:
Mr. J. H. MacMillan Vice President Post Office Box 1260 Lynchburg, Virginia 24505 Gentlemen:
i This refers to the Special Inspection conducted by Mr. D. G. Anderson of this office on September 25-28, 1979, of your facility at Lynchburg, Virginia, and to the discussions of our findings with members of your staff at the con-clusion of the inspection.
1 The main purpose of this inspection was to examine the measures which you have established for the reporting of defects and noncompliances under Part 21 of Title 10, Chapter 1, Code of Federal Regulations and to verify that these measures are being properly and effectively implemented.
The regional office has referred matters which may be considered for enforce-ment action to our headquarters office for their review.
They will correspond with you directly regarding those matters.
In accordance with Section 2.790 of the Commission's " Rules of Practice, Part 2 Title 10, Code of Federal Regulations, a copy of this letter together with the enclosed inspection report will be placed in the Commission's Public Document Room.
If this report contains any information that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public dis-closure. Any such application must incl.ude a full statement of the reasons on 8 005210 / C
The Babcock & Wilcox Company the basis of which it is claimed that the information is proprietary, and should be prepared so that proprietary information identified in the appli-cation is contained in a separate part of the document.
If we do not hear from you in this regard within the specified period, the repr,rt will be placed in the Public Document Room.
Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, l
6 Karl V.
yfrit Directo
Enclosures:
Inspection Report No. 99900400/79-03 i
-