ML19323D069

From kanterella
Jump to navigation Jump to search
Responds to NRC 800421 Request for Comments on NUREG-0662. Util Cannot Perform Comprehensive Evaluation of Rept Alternatives.Recommends That Decontamination of Bldg Atmosphere Be Expedited
ML19323D069
Person / Time
Site: Crane Constellation icon.png
Issue date: 05/15/1980
From: Curtis N
PENNSYLVANIA POWER & LIGHT CO.
To: Snyder B
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0662, RTR-NUREG-662 NUDOCS 8005200494
Download: ML19323D069 (1)


Text

.

8005200494 TWO NORTH NIN T H $7 R if f, A L L E N T OWN, P A. 18I01 P H O N E: (213) 8 71 3131 May 15, 1980 Dr. Bernard J. Snyder Program Director Three Mile Island Program Office Office of Nuclear Reactor Regulation United States Nuclear Regulatory Commission Washington, D. C.

20555

Dear Dr. Snyder:

This is in response to your letter of April 21, 1980 requesting comments on the NRC's " Environmental Assess-ment for Decontamination of the Three Mile Island Unit 2 Reactor Building Atmosphere" (NUREG-0662).

Due to other demands on our limited resources, we are unable to perform a comprehensive evaluation of the various alternatives dis-cussed in NUREG-0662.

We are, however, of the opinion that decontamination of the Three Mile Island Unit 2 Reactor Building Atmosphere should be completed as expeditiously as possible giving due consideration to any potential risks to the public health and safety from the various alternatives available.

We have no reason to believe that the Staff's recommendation to purge the reactor building atmosphere into the environment is not technically sound or environmentally acceptable.

Very truly yours, Norman W. Curtis Vice President Engineering 4 Construction N

c b(k P E N N S Y L V A NI A POWER & L I GH T' COM P ANY

-