ML19323C981

From kanterella
Jump to navigation Jump to search
Forwards LER 80-045/01X-1
Date released: 12/03/2019 Download: ML19323C981


LER 80-045/01X-1:on 800404,during Cold Shutdown,Leak Rate Test of Air Supply Accumulator Check Valves,For Automatic Depressurization Sys Valves Revealed Unacceptable Leakage Rate.Caused by Heat Damage from Installation Welding
ML19323C988
Person / Time
Site: Hatch 
Issue date: 05/12/1980
From: Coggin C
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323C988 (2)
Forwards LER 80-045/01X-1
ML19323C980
Person / Time
Site: Hatch 
Issue date: 05/12/1980
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323C980 (1)