ML19323C841
| ML19323C841 | |
| Person / Time | |
|---|---|
| Issue date: | 03/28/1980 |
| From: | Potapovs U NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV) |
| To: | Cleveland N STONE & WEBSTER ENGINEERING CORP., STONE & WEBSTER, INC. |
| Shared Package | |
| ML19323C842 | List: |
| References | |
| REF-QA-99900509 NUDOCS 8005190283 | |
| Download: ML19323C841 (2) | |
Text
'Pb 2-RQs kN
/
3, UNITED STATES y *.s-lgy j NUCLEAR REGULATORY COMMISSION
, e):[/
,8 80051901D REGION iv 3, Mk g
611 RYAN PLAZA DRIVE, SUITE 1000 J
h,.....f
~~
? 8 MAR 1980 Docket No. 99900509/80-01 Stone and Webster Engineering Corporation ATTN: Mr. N. B. Cleveland Vice President, Quality Assurance P. O. Box 2325 Boston, Massachusetts 02107 Gentle =en:
This refers to the QA program inspection conducted by Mr. D. G. Anderson of this office on March 10-14, 1980, of your facility at Boston, Massachusetts, and to the discussions of our findings with you and members of th.e S&W staff at the conclusion of the inspection.
Areas examined during the QA program inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.
Within the scope of this inspection, we found no instance where you failed to meet NRC requirements.
In accordance with Section 2.790 of the Commission's " Rules of Practice,"
Part 2, Title 10, Code of Federal Regulations, a copy of this letter together with the enclosed inpsection report will be placed in the Cec: mission's Public Document Room.
If this report contains any informa-tion that you believe to be proprietary, it is necessary that you make a written application within thirty (30) days to this office to withhold such information from public disclosure. Any such application must include a full statement of the reasons on the basis of which it is clai=ed that the information is proprietary, and should be prepared so that proprietary information identified in the application is contained in a separate part of the document. If we do not hear from you in this regard within the specified period, the report will be placed in the Public Document Room.
s Stone and Webster 2
Engineering Corporation Should you have any questions concerning this inspection, we will be pleased to discuss them with you.
Sincerely, f etki l g-U
- Potapovs,
!.et Vendor Inspection Branch
Enclosure:
Inspection Repcre No. 99900509/80-01 l
l i
l r
l i..
_