ML19323C603

From kanterella
Jump to navigation Jump to search
Forwards LER 80-068/03L-0
Date released: 12/03/2019 Download: ML19323C603


LER 80-068/03L-0:on 800422,while Performing Primary Containment Hydrogen Recombiner Sys Functional Test, Recombiner Sheath Temp Failed to Remain within Tech Spec. Caused by Stored Energy in Heaters.Procedure Revised
ML19323C608
Person / Time
Site: Hatch 
Issue date: 05/08/1980
From: Baxely S
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323C608 (2)
Forwards LER 80-068/03L-0
ML19323C602
Person / Time
Site: Hatch 
Issue date: 05/08/1980
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19323C602 (1)