ML19323B630

From kanterella
Jump to navigation Jump to search
Responds to IE Bulletin 80-02 Re Inadequate QA for Nuclear Supplied Equipment.Insp Revealed No Apparent Operational Problems in Feedwater Spargers Prior to 1977 Removal.New Spargers Had Certain Problems & Were Subj to Mods
ML19323B630
Person / Time
Site: Hatch  
Issue date: 04/16/1980
From: Widner W
GEORGIA POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
IEB-80-02, IEB-80-2, NUDOCS 8005140001
Download: ML19323B630 (4)


Text

_ _ _ _ _ _ _ - _ _ _ _

Georg:a Power Comp"ny

  • ,230 Peachtree S're;1

__,,__7.----

8 0 0514 000t

/

Post Office Box 4545 Atlanta, Georgia 30302 Telephone 404 522-6060 A

'n Power Generation Department Georgia Power t!v scchern entre syst n

[ '." bl

' l,' S U April 16, 1980 United States Nuclear Regulatory Commission

REFERENCE:

Office of Inspection and Enforcement RII-JPO -

Region II - Suite 3100 750-321/50-3 h 3 101 Marietta Street, NW

&E BulleEin 80-02 Atlanta, Georgia 30303 ATTENTION:

Mr. James P. O'Reilly Gentlemen:

The Georgia Power Company hereby submits the following information in response to your letter dated January 21, 1980, concerning I&E Bulletin 80-02, " Inadequate Quality Assurance For Nuclear Supplied Equipment".

la.

Reactor feedwater spargers and thermal sleeves manufactured and/or supplied by Marvin Engineering Company are currently installed at E.

I. Hatch, Units 1 & 2.

Subject spargers and thermal sleeves were supplied by its NSSS supplier, General Electric Company, San Jose, California.

Ib.

The original Unit 1 feedwater spargers were ordered January 1969 by Georgia Power Company (GPC) purchase order #PEH-2.

Replacement spargers for Unit 1 were ordered January 1976 (GPC p.o. #R-19204) and March 1978 (GPC p.o. #C-04525). Original Unit 2 feedwater spargers were purchased January 1969 (circa).

The feedwater spurgers are perforated stainless steel headers located in the mixing plenum above the downcomer annulus. A separate sparger is fitted to each feedwater nozzle and is shaped to conform to the curve of the RPV wall. Feedwater flow enters the center of the spargers and is discharged radially inward to mix the cooler feedwater with the downcomer flow from the steam separators before it contacts the RPV wall. The feedwater also condenses the steam in the region above the downcomer annulus and subcools the water flowing to the jet pumps and recirculation pumps.

During an accident J

condition, feedwater piping /spargers are used to deliver water from

,~~

,lJPCI and RCTC systems so that water inventory is maintained,in the reactor vessel.

~

MCTAL C055'3

-m s..-.

r

~

Georgia Power 1 Mr. James P. O'Reilly April 16, 1980 Page 2 2.

History of Unit 1 Feedwater Spargers Unit I feedwater spargers we. - received on site from General Electric Company on May 30, 1972.

Thesi "ero,ar*

" GPC p.o. #P EH-2, requisition #37002-55. All documento.; e

,r these spargers are in the possession of General Electric, San Jose.

The documentation received on site was in the form of a Product Quality Checklist, a common document supplied by General Electric.

The GPC Hatch MPL number for these spargers is listed as Bll-D081.

Inspection reports show these spargers as being installed during the summer of 1973 (Reference Plant Hatch Mech. Inspectors Daily Reports dated June 5, 1973, June 13, 1973, June 18, 1973, June 19, 1973, June 20, 1973, and June 21, 1973).

During the period between the time of original installation and the removal of the originally installed spargers in the spring of 1977, no apparent operational problems were encountered.

In the spring of 1977, the Unit 1 feedwater spargers were removed to facilitate the installation of a new design sparger supplied by G E.

This modification consisted of installing a forged tee assembly.

This work was performed and documented on GPC Maintenance Request 77-638 and 77-1426.

These MR's were used to implement GPC Design Change Request 77-154 which was the licensee's procedure to implement the GE FDI-124/12000.

Upon receipt of these spargers and associated installation materials, inspections were performed on those items. Visual and Liquid Penetrant examinations were performed and as a result, several non-conforming items were discovered.

The inspection processes used, results and resolutions of the up;cceptable findings were documented and are on file at the plant si'.e.

Installation of these new I'orged tee spargers was completed in May of 1977, and remained in the system until the spring outage of 1979 (May-June) at which time a new type dual piston sparger assembly was installed. From the period ofi hy 1977 through May 1979, no operational problems occurred involving the feedwater spargers.

At the time of the dual piston-type sparger installation, (May-June 1979) the cladding around the sparger nozzles was removed. During 3,_

.the. clad removal process, no significant problems with clad _ cracking was observed, which was the major reason for the new modification.

l I

l

r Georgia Pbwerd Mr. James P. O'Reilly April 16, 1980 Page 3 This modification was performed under the supervision of General Electric, and is documented on GPC Maintenance Request 1-79-148 and authorized by GPC Design Change Request 1-78-202, Rev. 1.

These type sparger assemblies are currently installed in the Unit 1 Reactor and as of this date, no operational problems associated with these spargers have occurred.

History of Unit 2 Feedwater Spargers These spargers (Unit 2 MPL #2B11-D081) are or:.ginal construction components and have not been replaced since tie original construction.

These spargers were supplied by General Electiic and installed by Reactor Controls, Inc.

Upon receipt prior to installation, visual and liquid penetrant examinations were performed on the material.

Several nonconforming items were documented during this inspection.

These nonconformances were resolved by repairing the nonconforming items.

The spargers were installed between the months of March and May of 1977.

Since the time of their initial installation, no operational problems i

have occurred involving these spargers.

Summary All documentation associated with the receipt and installation of these spargers for both Unit 1 and Unit 2, and the modifications associated with the Unit 1 spargers is on file at the plant site.

I 3.

During manufacture of feedwater sparger and thermal sleeves, GPC Quality Assurance personnel made inspections at Marvin Engineering Company.

Contacts during these inspections included representatives from Marvin Engineering Company, General Electric Company, and CBI Nuclear. Welding and nondestructive testing procedures were reviewed and found to be in good order.

Appearance of welds was good and liquid penetrant examination results were satisfactory on the particular welds checked. Jigs and fixtures to held the spargers while being welded and fitting of the nozzles were adequate. Final inspection, consisting of visual examination of sparger sections, together with the thermal sleeves, and critical dimensio s check 4

were satisfactory. Upon receipt of material by the plant site accompanying documentation is checked for completeness by Quality 3__

- -. Control personnel per purchase order requirements and is subject to audit by Quality Assutance personnel.

l

_ ~ - - _ _..

k

=

r-s GeorgiaPowerd l

Mr. James P. O'Reilly April 16, 1980 Page 4 If you have any questions or comments in this regard, please contact my office.

Very truly yours, h

. - -, _ __ Q s

W. A. Widner Vice President and General Manager Nuclear Generation JAE/ DAM /mt xc: Director of the Office of Inspection and Enforcement Director of the Division of Operating Reactors, Office of