ML19323A991

From kanterella
Jump to navigation Jump to search
Forwards Notice of Violation & Notice of Proposed Imposition of Civil Penalties from Investigation on 800102-29
ML19323A991
Person / Time
Site: 05000054, 07000687
Issue date: 04/07/1980
From: Stello V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: Bollinger R
UNION CARBIDE CORP.
Shared Package
ML19323A992 List:
References
NUDOCS 8005090078
Download: ML19323A991 (1)


Text

l l Y p recu e

o UNITED STATES E5 I,h NUCLEAR REGULATORY COMMISSION 9 C W ASHINGio N, D. C. 20555

/

8 065090 0-N APR 7 1980 Docket No.70-687 50-54 Union Carbide Corpora *, ion ATTN:

Mr. R. E. Bollinger Vice President Nuclear Products P. O. Box 324 Tuxedo, New York 10987 Gentlemen:

The findings of our investigation on January 2-29, 1980, of events involving the transport and disposal of low specific activity radioactive waste from your facility, on or about December 10, 1979, revealed that your activities were not in full compliance with NRC regulations.

The item of noncompliance is described in Appendix A to this letter.

In view of the circumstances surrounding these events, we are proposing a civil penalty in the amount of Three Thousand Dollars for the item of noncompliance as set forth in Appendix A.

Appendix B to this letter is the Notice of Proposed Imposition of a Civil Penalty.

You-are required to respond to this letter, and in prepa~ing your response you should follow the instructions in Appendices A dnd B.

Your written reply to this letter, combined with our findings from our continu-ing inspection program, will be considered in determining whether any further enforcement action, such as modification, suspension or revocation of the license, is appropriate.

In accordance with Section 2.790 of the NRC's " Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a copy of this letter and the enclosures will be placed in the NRC's Public Document Room.

Sincerely, f(

N r,

VictorSte}o,Jr Director Office of Inspection and Enforcement

Enclosures:

1.

Appendix A, Notice of Violation 2.

Appendix B, Notice of Proposed Imposition of Civil Penalties CERTIFIED MAIL RElVRN RECEIPT REQUESTED