_ - -

8005070 (00 tuumnw nuu n sas sun y

y PRELIMINARY NOTIFICATION Of EVENT OR UNUSUAL CONCURRLNCE--PNO-TMT-80-20 1

This preliminary notification constitutes EARI Y_ notice of evente. of POSSIBLL safety or public interest sinnih,ca,nce.

verification ur evaluation and,The information presented is.,as,,inicially, received withou,t, is ba[s,ic,a,lly all that, is known by NRC staff on -his date.

1 Tacility: Metropolitan Edison Company Three Mile Island, Unit 2 Middletown, Pennsylvania Docket Number ' 50-320

Subject:

TMI 2 Cround Water Mon 1toring Program Over the past few months eight ground water monitoring wells were drilled in various locations around the Unit 2 reactor building to detect leakage from the reactor building sump. Initial samples from the wells have been analyzed.

Samples from seven welle.

indicate tritium activity in the 1.6 x 10-7 to 9.9 x 10-7 uCi/mi range. Trittum activity in wcli No. 2 was initially 1.53 x 10-6 uCi/ml.

After the initial well water conten pumped out, a second sample was taken and indicated a tritium activity of 2.50 x 10 g was uti/ml.

Well No. 2 is located approximately 50 feet from the boraled water storage tank and 200 te::L from the reactor building.

Water samples from several wells were brown colored.

The source of the color was not determined.

1.icensee and NRC representatives are out' lining a program to determine the e.nurce of the tritium activity and the reason for the water disculurdLion.

Natural background tritium activity in the area as recorded by the EPA _is 2.00 x 10-7 uCi/ml.

Media interest is expected because off site notification of this data was made by the licensee.

The Commonwealth of Pennsylvania has been notitied.

A Dress release is not plannet by the licensee or the NRC.

This preliminary notification is issued for information only and thir. information is current as of 1:30 P.M.W A. }f.# 'i

.i f f.' Colk'o

Contact:

G: (Kalman 590-3957 ins 590-3955 Fasano 690-3960 J.

Prepared by Section Chief Ocputy Prog'r'am Manager

' ' ~ ~ '

Distribution:

(facsimile Iransmission Times Noted)

H 5t Bldg Chairnian Ahearne Commissioner Bradford

5. J. Chilk, SECY Commissioner Kennedy Comissioner Hendrie C. C. Kammerer, CA Commissioner Gilinsky ACRS (1or Distribution)

MNB Bldg P. Bldg TF:X005

(!L:HO Dist.)

W. J. Dircks, LD0

11. R. Denton, NRR C. Michelson. AEDO D. R. Nuller. NRR Landow Bldg)(Fathy, }Q),

J. J. Fouchard, PA R. 1. Mattson. NRR (6 min /page fi. M. Haller, MPA D. Vassallu. NRR R. G. Ryan, OSP D. Eisenhut, NRR J. il. Cummings. DIA H. K. Shaper. ELD R. H. Vollmcr. NRR B. J. Snyder. NRR (tiAIL)

Region I R. Minogue, SD R1gion II _

Willste 81dg' IE:X005 Region III J. G. Davis, NMSS Region IV R. Budnitz, RES Rigion V

..