ML19323A575

From kanterella
Jump to navigation Jump to search
Forwards Util to NRC Providing Further Info Re Util Response to Certain NRC Requirements Resulting from post-TMI Evaluations.Info Is Not Relevant to Proposed Spent Fuel Pool Expansion
ML19323A575
Person / Time
Site: Big Rock Point File:Consumers Energy icon.png
Issue date: 03/24/1980
From: Gallo J
ISHAM, LINCOLN & BEALE
To: Grossman H, Paris O, Shon F
Atomic Safety and Licensing Board Panel
References
NUDOCS 8004210401
Download: ML19323A575 (2)


Text


_--

i

\\m, d%

ISHAM, LINCOLN & BEALE COUNSELCRS AT LAW 1120 CON NCCTICUT AVENUC, N. W.

SusTC 325 WAS HINGTON, D. C. 200 36 TELEPHONC 202*S33*9730 CMsCAGO OrtsCC ONC Fins? NATIONAL DLAZA FORTV-SECONO FLOOR CM'CAGO. tLLINCIS 60803 TELEPMONC 392 *SSe *7500 TELCx:2*S2SS March 24, 1980 Herbert Grossman, Esquire Dr. Oscar H. Paris Atomic Safety and Licensing Atomic Safety and Licensing Board Panel Board Panel U.S. Nuclear Regulatory U.S. Nuclear Regulatory Commission Commission Washington, D.C.

20555 Washington, D.C.

20555 Mr. Frederick J.

Shon Atomic Safety and Licensing Board Panel U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Re:

In The Matter Of Consumers Power Company (Big Rock Point Nuclear Power Plant),

Docket No. 50-155 Gentlemen:

Consistent with the tenets of full disclosure as articulated by the Atomic Safety and Licensing Appeal Board in McGuire,* Licensee is submitting the enclosed letter for the information of the Licensing Board and the parties.

The letter, dated March 14, 1980, from David P.

Hoffman to Dennis L.

Ziemann of the NRC provides further information concerning the Company's response to certain NRC require-ments resulting from post-TMI evaluations.

Duke Power Company (William B.

McGuire Station, Units 1 and 2), ALAB-143, 6 AEC 523, 625-26 (1973).

i 800.4210401

l

' l It is the Company's view that none of the matters discussed in Mr. Hoffman's letter is relevant to the pro-posed expansion of the capacity for the Big Rock Point spent fuel pool -- the subject of the above-captioned proceeding.

Nevertheless, the letter is being submitted consistent with the Company's policy of complete disclosure.

Sincerely, ose h Gallo One of the Attorneys for Consumers Power Company JG/kar Enclosure cc: Service List i

i

+

l t

4'{ $ h g[pQDOO 099 T CORSum8f5 MAR 19 2 p

.)LW9Und V b i

ggy c.

Cro

.4 j

Generas Omces: 212 West Micndgan Avenue. Jackson, Micnigan 49201. Area Code S17 788 0550 W

March 14, 1980 l

Director, Nuclear Reactor Regulation Act Mr Dennis L Ziemann, Chief Operating Reactors Branch No 2 US Nuclear Regulatory Conunission Washington, DC 20555 i

DOCIGT 50-155 - LICENE QPR BIG ROCK POINT PLANT - SHORT-TZRM LESSONS LEARNED FROM THREE MILE ISLAND ACCIDENT: ADDITIONAL INFORMATION REQUESTED DURING SITE VISIT An NRC inspection team under the direction of Mr Charles Long visited Big Rock Point February 2S and 29, 1980. This team reviewed actions taken at Big Rock Point in response to NRC requirements resulting from review of the accident at Three Mile Island (TMI). As a result of this review, Consumers Power Company agreed to pyovide certain additional information and documentation. to this '.etter provides responses to the specific items of additional information requested during the NRC site visit.

Enclosurs 2 provides Revision 2 to the enclosure of Censumers Power Company's December 77, 1979 letterProperty "Letter" (as page type) with input value "05000000/LER-1986-005-03, Informs of Planned Site Visit to Obtain Info Supporting Implementation of Emergency Response Data Sys,Including Availability of PWR or BWR Parameters in Digital Form & Characterization of Available Data Feed Points"December 77, 1979" contains a sequence that could not be interpreted against an available match matrix for date components." contains invalid characters or is incomplete and therefore can cause unexpected results during a query or annotation process. describing actions to be taken in response to post-TMI requirements.

(Revision 1 was submitted by Consumers Power Company letter i

dated January 18, 1980.) Revision 2 updates our response to include the additional information discussed in Enclosure 1 to this letter. Revision 2 l

also cakes minor changes reflecting the completion of certain actions t

coranitted in the original response, and incorporates deferral of certain I

modifications pending a plant risk assessment as discussed :.n Consumers Power Company letter dated February 22, 1980.

i David P Hoffman (Signed)

N Qs C\\ _

David P Hoffman 1

Nuclear Licensing Administrator em g,

/

ns s

CC JGKeppler, USh7C DUPLICATE DOCUMENT Enclosures (1) Additional informatio Entire document previously entered February 13-29, 1980.

Into system under:

(2) Rev 2 to December 27' ANO ghC 3 / 9() (3 k No. of pages:

t