o and uncoRassm g SHAw, PITTM AN. PoTTs & TROWB RIDG E 18 0 0 M STAECT,N.W.

WASHINGTON, D. C. 20C36 s

ma=SAv c.soTvt STEPMCN S. DeUTTLER

( a o2133e - Aeoo SvCuant L. peTTwAN a:NTMaoP N. SWowN oconor r. Toowenicot

.AucS s. Mane uN st r oM c N o.moTTS

=coEnT C.zAMLam TCLCCopiCR Ns"L=LN o.*soSTYsCaIo n~c a"? sInos'e s"N S tacas ase oesA 6 ase s7eo s.T of.ev MANLoN STCvCN u.LUCAS o tesor m. acosmS. Jo.

= ATiaS r. TmAv8CSo-otAz

,,3 JoMN e mMeNCLANDER VICTCRIA J. PCERINS

../

l TELEN seUCr w. CMumCNeLL JoMN M.o'NEILL.JN.

LESuC 4. NsCMobsoN.Ja.

Jar A. CPSTiCN es.2eea (SMAwtAw wSMs esamfiN Q. RN ALL AANo L. ALLEN

.O,,

d CA B LC " S M AwbAw "

RsCMacD J. M ENDALL

?IMoTMy 3. one sma DC

  1. "4

/

JAv C. SsLStao Cu sA s CTM u. ecN oLCToN

/

1^"e"C "k"Lc'N'T' WM2:.'A,#'

f'l "

CoWNSEL

"^

A Eo-^ao

  • cao='a~o o

ww. SRADFoRO NCTNoLoS MANNy M. oLASSplEoEL FECD A. uTTLE TMowAS M. McComuscu sFRED OmaSNER SUSAN Q.FALRSoN gg g

'NATH ANICb P. B AE CD. JA.

wlbuAM P. SANN w

g G e

MAen AuoENeuCR JoM M L. CAmm. JR.

,O EIN CST L. SLAn t. JR.

pMita s J. MAnvCT q

Q CAnLcToM S. JoN ES nontar u. ooacoN g

TMome AS A. 8ARTER J CANN E A. CALO CRCN JAM ES M. Rumote aAmeARA J. Momo EN.

k S MCLOoM J. wCeSCL soNNIC S. ooTTLICE h

JoMN A. McCULLoWoM ALFRED M. PoSTELL e%

J. DATRICE McCn CT SCTM M. MoooAS SAN JAMES TMoh8AS LENHANT S M EILA C.MeCAFFERTT STCVEN L. m CLTZ C A DEU S sa A. ptDoway C8I CEAN D.AUUCK M CNDe ETH J. MAUTMAN JOMM ENoEL CAvs0 LAwmCMCE MikkCN

  • eso? Acaservto tes o.c.

February 6, 1980 l

Alan S.

Rosenthal, Chairman Atomic Safety and Licensing Appeal Board U.S. Nuclear Regulatory Commission Washington, D.C.

20555 Dr. John H.

Buck Atomic Safety and Licensing Appeal Board U.S.

Nuclear Regulatory Commission Washington, D.C.

20555 Dr.

W. Reed Johnson Atomic Safety and Licensing Appeal Board U.S.

Nuclear Regulatory Commission Washington, D.C.

20555 In the Matter of METROPOLITAN EDISON COMPANY, et al.

(Three Mile Island Nuclear Station,. Unit No. 2)

~

l Docket No. 50-320 ~

l Gentlemen:

.This letter reports on a program initiated by Metro-politan Edison Company and carried out'in the period August 30, 1979, to January 22, 1980, in an attempt to check on the flight paths of large aircraft (potentially weighing over 200,000 pounds) using,the Harrisburg International Airport.

The program 800310 0 c 2 2_D

r

(

SHAW, PITTMAN, POTTS & TROWSRIDGE F

February 6, 1980 t

Page Two used the security force at the North date of Three Mile Island E

as " spotters" and recorders of flight observations.,For reasons explained more fully below, the recorded observations proved t

to be too inaccurate to be of any probative value.

Neverthe-E less, in the interest of complete disclosure, we are informing I

the Board of the details of the program and of its results.

4' Security personnel at the North Gate were instructed to record on forms provided to them.information as to any air-craft (including small aircraft) which they observed either io landing at or taking off from the airport and passing near or.

[

over Three Mile Island.

They were initially asked to record among other data the time of their observation; whether the air-craft was arriving or departing; whether or not the aircraft i

flew over any part of Thres Mile Island (not just the plant area); and the type of aircraft.

Later, the instructions were extended to include recording data on the configuration of the aircraft (number of engines, type and location, and airline marking if visible).

To assist the gnards in identifying large aircraft they were provided with silhouettes (front, side and bottom) of both scheduled jet aircraft at HIA and other jet ' aircraft which may occasionally use the airport.

Silhouettes of the B-727, DC-9, B-737 and BAC-111 (less than 200,000 pounds) were included in the hope of avoiding misidentification of these i

aircraft.

As a check on the accuracy of observations Met Ed also' planned to review flight strips at HIA listing the times 3

of arrival and departure of all large aircraft, which data could then be checke' '. gainst recordings of large aircraft by the spotters.

Unfor.nately, the first attempt to compile the flight strip data did not occur until early in December.

Since in accordance with FAA practice flight strips are destroyed after 30 days of retention, the flight strip information ob-tained by Met Ed covers only the period October 31, 1979, to January 22, 1980.

Thus, it has not been possible to check the l

spotters' data prior to October 31, 1979.

There were a number of deficiencies in the execution of the program.

On some days no spotter observations were re-corded a.'.though about 76% coverage of the period was accom-plished.

Further, information which was recorded was incomplete, although the information did regularly include at least the time.of arrival or departure and whether or not the aircraft flew over the Island and in most cases included either an iden-tification of t,he type of aircraft or the number and location of engines or both.

Finally, as indicated below, spotter

i I

SHAW, PITTMAN, POTTS & TROWB RIDGE j

.k February 6, 1980 Page Three

[

identifications of aircraft type proved to be highly unreliable.

h Met Ed attributes the foregoing deficiencies in part.to the routine rotation of security personnel at the North Gate, per-

[

sonnel changes and conflict of the spotter program with other a

duties of the security force.

During the data collection period, g

observations were recorded and initialed by at least 100 dif-

'Ii ferent individuals.

Because of these recurring difficulties Met Ed discontinued the spotter program on January 22, 1980.

i" The following is a summary, with comments, on the spotters' recorded observations:

E 1.

During the entire period of the program (August 30, 1979 - January 22, 1980) the spotters recorded a substantial i

number of' private and commercial planes weighing less than i

200,000 pounds, including some B-727's which flew over the

+

Island.

Met Ed has made no attempt to verify the accuracy of these observations.

{,

2.

During the period August 30 - October 30, 1979,

-I spotters reported a total of 26 large aircraft, mostly B-707's

~

and B-747 's, as having flown over the Island.

The majority of these recordings, i.e.

18, were made in the first month.of the program, i.e. from August 30 through the end.of September,.

?

when the spotters were least experienced.

The recordings dropped

?'

to 5 in the first half of October and to 3 in the last half of i

October.

Met Ed cannot reconcile these observations with infor-

[

mation as to flight paths for large aircraft obtained from FAA

[.

controllers and frem discussions'with TWA pilots.

It also can-not reconcile the number of B-747's recorde.1 with the types of planes listed as in use in commercial airlite schedules.

As previously noted, Met Ed has not been able to check the spotter

~

observations against fli'ght strips for the period in question.

y There is no reason, however, to believe that the pre-October 31 l

l observations were any more reliable than the post-October 31

[

observations, which are described in the next paragraph, whi~ch have been checked against flight strips and all of which appear to be incorrect.

l 3.

During the two and one half month period from Octo-ber 31, 1979, to January 24, 1980, i.e. the period for which

' Met Ed obtained data from the HIA flight strips, the spotters recorded only 9'large aircraft over the Island.

None of these observations appear to have been correct.

In 5 cases the iden-tification of aircraft type was inconsistent with the number and 1.ocation of,en'gines also recorded by the spotter.

Further, an-

s SHAW, PITTMAN, POTT.S & TROWBRIDGE February 6, 1980 Page Four

?.

in no case does the HIA flight strip show either an aircraft of Ee type identified by the spotter or any other large air-craft to have landed or taken off from HIA at anywhere near i

the time recorded by the spotter.

if E

4.

As a further check on the spotter observations,

~ 5 Met Ed has checked the flight strips for the period October 31, 1979 - January 22, 1980, for the time of arrival or departure of each large aircraft using HIA.

The spotter recordings do not show a single observation of a large aircraft which coin-E+ -

cides even approximately with the landing and take-off times shown on the flight strips.

E5 We conclude from the above that the spotter identifi-cation of aircraft proved to be entirely unreliable, although the results of the program do strongly suggest that none of the heavy aircraft that were recorded by flight strips as having je used the airport flew near enough to TMI to be spotted.

Sincerely,

~