ML19322D208

From kanterella
Jump to navigation Jump to search
Documents Action Taken by NRC Re 790815 Order Confirming Suspension of Const on Marble Hill
ML19322D208
Person / Time
Site: Crane, Marble Hill  
Issue date: 08/15/1979
From:
NRC COMMISSION (OCM)
To:
NRC COMMISSION (OCM)
References
TASK-TF, TASK-TMR NUDOCS 8002100053
Download: ML19322D208 (1)


Text

___ _ _ _ _ _ _ _ - -

ORDER ACTION Public Service of Indiana Licensee:

CATEGORY 1000 East Main Street Reactor (construction) 1 Plainfield, Indiana 46168 Reactor (operational)

Marble Hill Units 1 & 2 Facility:

yo,y 50-546 CPPR-170 Facility Docket No.

En-En

. License No. cono_ p y Materials Type:

ORDER CONFIRMING SUSPENSION OF CONSTRUCTION Issue Date:

August 15, 1979 Reason for Order:

Identification over the past few months of serious problems at the Marble Hill facility relating to the adequacy of concrete placement and the licensee's quality assurance program.

The licensee issued a i

stop work order on August 7, 1979, for all safety-related construction and this Order is to confirm the licensee's action.

S m ry.

Under the terms of the Order, the licensee shall not resume safety-related construction activity on the Marble Hill Units 1 & 2 nuclear power station until the licensee submits in writing under oath to the Director, Office of Inspection and Enforcement, l

a description of its revised quality assurance program l

and the steps taken to assure that safety-related I

construction will be conducted in acesrdance with i

Appendix B of 10 CFR Part 50 of tb; Commission's regulations; and the IE Director nas confirmed in l

writing that reasonable assurance exists that safety-related construction activities will be conducted in accordance with such requirements.

Such confirmation may extend in whole or in part to the suspended construction activities.

Further Action:

80021000 7 3 G