" COLD" LICENSE TRAINING PROGRAM 4

W

(_,)

PURPOSE This program is intended to prepare a power plant operator to become a licensed reactor operator or senior reactor operator under the provision of Section 55.25(b) of 10 CFR, Part 55.

APPLICABILITY The cold license training program is required for all candidates for reactor operator or senior reactor operator license for each new nuclear power plant.

Depending upon the qualifications of individual candidates who have had previous nuclear power plant operating experience, portions of this program may be waived by the USAEC on a case by case bases for specific individuals.

PROGRAM The " cold" license training program consists of five (5) phases, and they are normally completed in order. The specific phases are:

Phase I Basic Nuclear Theory Phase II Nuclear Power Plant Operation Observation Phase III PWR Technology Phase IV Nuclear Power Plant Simulator Operation Experience Phase V On The Job Experience Phase I A course of classroom study comprised of basic physics, mathematics, heat transfer, fluid flow, and plant operations.

Phase II & IV Operational experience gained in actually being involved with operation of a power plant and operating a nuclear power plant simulator.

For those trainees who do not gain sufficient actual reactor operating experience during the Phase II portion of the program, an operational period on the B&W Training Reactor will be required in order to be eligible for examination as a " cold" license candidate.

Phase III The presentation of the design details of how the specific nuclear steam I

supply is constructed and how operating systems accomplish their functions.

Phase V On the job experience, gained while operating their own plant during the test programs and writing operating and test procedures.

The specific details of each of these programs are contained in the following sections.

?

800120001y

f PdMt4 IWCL

[

(Program 0 - )

9 f

t f

COURSE DURATION - 13 weeks, 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> / week classroom time.

V TRAINING LOCATION - Customer's discretion.

s l

PURPOSE - To provide the prospective nuclear power plant operators with a basic foundation in nuclear engineering, reactor theory, and nuclear physics so that he

{

l can successfully pursue later phases of instruction covering operations, construc-I tion, technical specifications and operating and casualty procedures of a nuclear power plant.

APPLICABILITY - High school graduates, with demonstrated aptitude in mathematics, chemistry and physics.

COURSE CONTENT - Covers basic subjects in areas of mathematics, atomic physics, reactor physics, heat transfer, introductory nuclear instrumentation, shielding and health physics, as outlined below:

Estimated Subject Matter Time, Hr.

Arithmetic Computations, exponentials, roots, logarithms, math 1.

tables, slide rule usage, curve plotting.

Algebra Notation, addition and subtraction, factoring, fractions, squares, cubes, solution of equations, simultaneous 30 equations.

Trigonometry 3efinitions of functions, angles, plane triangles, trigo-15 nometric tables.

Introduction to Calculus Derivatives and differentials, integration, series, tables of derivatives and integrals, approximate methods of in-tegration, ordinary differential equations, graphical rep-resentation of variables.

10 Atomic Physics Atomic nature of matter, nuclear chcracteristics of the elements, fundamental particles and rays, radioactivity and decay, induced nuclear reactions.

60 Reactor Physics Terminology, fission process and chain reactions, properties of neutrons, multiplication factors, criticality, flux and power, reactor operation and control, reactivity, reactivity coefficients, safety.

90

(

L 4_

K Eatimatsd Subject Matter Time, Mr.

Heat Transfer and Fluid Flow Thermal properties of bodies, gases, vapors, transmission of heat by conduction and convection, viscosity, pressure, liquids in motion, steam and compressed liquid tables, ex-pansion of gases and vapors, application to reactor design.

75 Introduction to Nuclear Instrumentation Radiation detectors, principles of operation, radiation detector types, pulse-type neutron detectors, integrating detectors, detector design factors, ion current measure-ment, scales and counters, typical systems.

30 Shielding Functional requirements, sources of radiation, materials and shielding types of various radiations, shielding geom-etry, principles of shield design.

30 Health Physics and Radiation Safety Health physics practices, biological effects of radiation, radiation units and dosages, exposure levels, review of federal regulations.

30

PRASE II - PRACTICAL OPERATINb EXPERIF.NCE (Program 0 - )

u.

COURSE DURATION - Trainees / Class - 8 Weeks /40 Hour

'er Week APPLICABILITY - Personnel without previous nuclear, Atrol room experience PROGRAM - Preplanned program of system tracing and evolution observation of the operation of a commercial nuclear power plant under supervision of full time B&W coordinator.

TRAINING LOCATION - At an operating PWR utility power plant, preferably with B&W supplied NSS.

DESCRIPTION This program is a familiarization phase designed to satisfy U.S. Atomic Energy Commission requirements concerning practical experience and to provide the trainee with an insight into actual operations and procedures in an operating utility type nuclear power plant.

The full time B&W coordinator will schedule classes, designate instructors, validate and sign off preplanned program check-lists, generate necessary documenta-tion and generally ensure that the trainees become familiar with operations within and outside of the control room.

It has been the policy of the USAEC to give credit for previous nuclear experience.

If in their opinion the trainee's background meets the intent of this program, the requirement to complete this phase may be waived by the USAEC.

The choice of plant is at the customers discretion; however, we will assist the customer in making the necessary arrangements if desired.

~

Y~'/

PHASE III - PWR TECHNOLOGY l

s#

(Program 0 - )

COURSE DURATION - 6 weeks, 30 hours3.472222e-4 days <br />0.00833 hours <br />4.960317e-5 weeks <br />1.1415e-5 months <br /> / week classroom ti=e, 28 =en/ class.

TRAINING LOCATION - Nuclear Training Center DESCRIPTION - This phase of operator training is designed to provide an in-depth series of lectures covering design and operation of the particular B&W plant the trainees will operate. This program is normally presented at the Nuclear Training Center in Lynchburg, Virginia.

A Training Supervisor is assigned to your group of operators when they arrive at the training center in Lynchburg for the beginning of Phase III.

The supervisor's dutier include preparation of course material, arrangements for instructors and classes, setting up special tutoring sessions, and generally assisting the trainees, singly and as a group.

The heavy investment in and concentration of unique facilities and staff, such as the PWR simulator, Lynchburg Pool Reactor, nodern classrooms, and instructors with design and service experience, make the training center at Lynchburg, Virginia, an ideal location for this phase of their training.

However, we can negotiate to provide this program at any location desired by the custocer.

The trainees will apply their experience as power station operators and begin to use the knowledge gained in earlier phases of the training program.

They learn how reactor physics, heat transfer, and fluid flow principles are factored into the design of the nuclear plant.

They are given an insight into the safety requirements for and descriptions of potential plant accidents and hazards. After st'udying applicable codes and regulations, they will better understand the need for the adminis-trative and design limitations on the operation of the p]s.nt.

Generally, they learn the similarities and differences in nuclear and fessil-fired power stations.

Operating personnel are inttructed in the detailed design and characteristics l

of the major components of the nuclear steam supply syster.

All facets of the instru-l l

tentatien and control systems are studied to_ ensure cceplete knowledge of the various k.

~2' J

i

/'

features of these systems.

Instruction is provided in water chemistry, radiochemistry, and health physics, as applied to the operation and maintenance of a nuclear plant.

The-refueling procedure and the operator's role in this operation are discussed.

Fundamentals of operating the plant are taught, and operators are informed of the normal and emergency operating characteristics, response, and capabilities and limitations of the nuclear system.

Finally, the precritical and posteritical test programs are studied in detail.

Estimated Subject Matte'r Time, Hr.

Reactor Physics Review of reactor physics as applied to the specific plant design.

15 Heat Transfer and Fluid Flow Review of the nuclear plant design, design objectives, re-actor design considerations and limitations.

15 Rcactor Vessel and Internals 1.

Reactor vessel design, materials, fabrication, in-spection, NDTT.

2.

Reactor internals description, design, materials, purposes.

3.

Design and fabrication of fuel elements and control rods.

7 - 1/2 Primary Loop Components 1.

Simplified two-loop heat transport system.

2.

Description of piping, pumps, and pressurizer.

3.

Design considerations, analysis performed, materials.

15 Once-Through Steam Generators Description, peculiarities, heat transfer characteristics, mechanical design considerations, materials, chemistry necessities, maintenance.

15 Reactor Auxiliary Systems 1.

Functional requirements (normal and emergency).

2.

Design objectives and criteria.

3.

Design approach and analysis.

Yf a

Estimstsd Sub_iect Matt 2r Tine, Hr.

r 4.

System-by-system description, equipment descrip-tion, arrangement, parameters.

5.

Equipment access and maintenance 30 Control Rod Drive's 1.

Description of drives.

2.

Description of controls.

7 - l'/2 Instrumentation and Control 1.

Functional requirements and description.

2.

Integrated plant control system.

3.

Nuclear instrumentation and reactor protection system.

4.

Primary loop non-nuclear instrumentation.

5.

Reactor auxiliaries non-nuclear instrumentation.

6.

Incore monitoring system description and function.

7.

Automatic data logging and on-line computer re-quirements.

30 Normal and Emergency Power Requirements 1.

Description of functional needs.

2.

Procedures.

7 - 1/2 Chemistry 1.

Water chemistry application to the nuclear plant.

2.

Radiochemistry measurements.

3.

Sampling and chemical analysis.

7 - 1/2 Health Physics 1.

Radiation monitoring systems.

2.

Decontamination methods and precautions.

3.

Administrative procedures and controls.

7 - 1/2 Safety Analysis 1.

Potential plant accidents and hazards.

2.

General public protection and acceptance.

3.

Administrative safeguards.

4.

Accident analysis (MHA, MCA, reactivity accidents, equipment failures such as loss of coolant flow).

15 Examination and Review 7 - 1/2 Total 180

PHASE IU - PMR OPERATION l

,1 i

(Program 0 - )

h GENERAL DESCRIPTION:

b This phase is an operational period in which classroom lectures and the B&W PWR simulator are used to provide a coordinated training effort in nuclear power station operatien. This program when combined with Phase II training provides operational experience required to meet the requirements expressed in USAEC Regulations Title 10, Part 55, Paragraph 55.25b. This period of training is directed toward the und'erstanding and actual completion of opera-tional procedures as they would be accomplished at a nuclear power station.

The training consists of five weeks of ins *ruction, split between classroom and operation of the PWR simulator and two weeks of shift operation, followed by an AEC type written and operational examination.

This program will thoroughly indoctrinate each man in the duties of his watch station. After first learning the details of plant design end construc-tion and the theory of operation in Phases I - III, the trainee is now schooled

'h in the practical conduct of plant operations. During the two week period of chift operations, the actual shift crews will operate the PWR simulator control roem as if it were a unit in commercial operation.

They will complete all shift functions and make all decisions on plant operction, as they will be l

required to do in the actual plant. Operational responsibility will be 3

a greater than that experienced at any power reactor.

l t

i i

l i

u.

u:

g+

Training in malfunction and emergency procedures is possible on the PWR The instructor simulator to an extent impractical on an operating reactor.

by interjecting will carefully probe the level of knowledge of each c<erator Major malfunctions various system and component failures into plant operation.

that cannot be conducted on an Operating reactor will be possible on the PWR simulator in complete detail.

C ompletion of this training program permits the operator to observe the responses of a PWR nucl' ear steam supply system to both This program demands response of an operational normal and abnormal conditions.

nature from each operator, for it is the operator who must make the necessary decisiens and initiate the required actions under actual plant conditions.

DETAIL COURSE DESCRIPTION Course Duration: 8 Weeks Class Size:

6 Men Per Class Training Location:

Nuclear Training Center Simulator Operation:

100 Hours (Minimum)

During this portion of the program, the trainees will be broken into groups of three for duty in the control room where e.un traitee will operate the simulator at each of the three operating positions. Approximately one third of the time will be spent as Shift Supervisor, Control Operator and Assistant Control Operator.

During the first five weeks the emphasis will be on operational orientation where the trainee will concentrate on learning the basic operations of the plant l

including casualty procedures.

The second part will consist of two weeks of shift operation where the trainees They will perform will operate the plant with minimal instructor assistance.

assigned evolutions and handle imposed casualties to develop confidence in their ability to handle a plant under all conditions.

During this phase, day to day progress of each trainee will be documented and evaluated with grcup and individual guidance provided by the training staff.

, CLASSROOM INSTRUCTION - 170 Hours An essential supple =ent to siculator operation is the related classroom instruction provided in this phase. Lectures will be given to review plant systems from an operational and functional view point rather than plant design.

Areas covered will include:

Fluid Systems Control Rod Drives Nucicar Physics Review Plant Instrumentation and Controls Reactor Protective System Reactivity Balance Soluable Poison Calculations Plant Operating procedures will be presented. in a planned sequence along with actual operations on the simulator. The following operations will be presented:

l Start Up Reactivity Control Power Operations Transient Control Loss Of Load Reactor Trip Casualty Precedures As with simulator operations, progress and study in this portion of the program will be documented and appropriate assistance and counseling will be provided to the trainees.

SIMULATED AEC TYPE EXM!INATION ATD REVIEW - 40 Hours Tnis portion of the program will consist of a complete exa=ination by.an experienced audit team of B&W staff members who have not been previoutly involved with training of the group. These examinations will closely simulate USAEC operator

'y

. -...-_ _ s examinations and the results of these examinations will constitute an audit individual and group competence.

This audit will be reviewed with plant canagement to appraise them of strengths and weaknesses in their operating staff.

TOTAL COURSE:

170 Hours Lectures, Observation, Study and Counseling 100 Hours Simulator Operation 40 Hours Examination, Reviews and Examination Preparation 310' Hours Total e

1 f

I i

PRASE IVA -PWR OPERATION (B&W NUCLEAR TRAINING REACTOR OPERATION)

(Program 0 -

Optional)

COURSE DURATION - 2 Weeks CLASS SIZE - 6 Men Per Class TRAINING LOCATION - B&W Nuclear Training Reactor - Lynchburg Research Center PURPOSE This program is intended to supplement the eight week Phase IV - Simulator Program 0 -

for those trainees without prior nuclear experience, and who have not had actual start up experience on a real reactor.

Trainees will operate the B&W Nuclear Training Reactor in at least three different core configurations, and will get a minimum of ten start ups each.

Areas covered will include:

Control Rod Calibration Increase Multiplication'With Rods Increase Multiplication With Fuel Power Distribution Measurements Detection Systems Basic Health Physics Reactivity Effects It is recommended that this program be included in the simulator training program as it will serve as an excellent review of reactor theory in a laboratory environment. Experienced operators will find the course stimulating and very worthwhile.

If the course is selected it will be integrated into the customers Phase IV simulator program, making the entire program ten (10) weeks in duration.

]

w..t r$t y

^

PHASE V - ON-THE-JOB TRAINING

[

(Program 0 - )

COURSE - Approxihately ten months TRAINING LOCATION - Job Site DESCRIPTION A resident on-site B&W Training Coordinator knculedgeable in design and operation of the nuclear plant will assist the plant superintendent in establishing an effective program during this final phase of operating staff training.

The B&W Training Coordinator will tailor our ccmplete preplanned, package to suit the requirements of your particular plant.

His responsibilities will include:

1.

Scheduling 2.

Training Records 3.

Evaluations 4.

Ascistance in development of lesson plans 5.

Assistance in locating outside resources when required 6.

Evaluation of instructor presentations 7.

Reports 8.

Reviews and preparation for USAEC " cold" license examinations 9.

Development of a plant training program During this phase of the program as fuel loading is approached a " mock" AEC written examination and walk-through oral examination for each license applicant by a team of B&W examiners will be conducted. The results of this examination will be used to advise the trainees and their management of possible areas of weakness that should be corrected before taking the USAEC " cold" license exacinations.