ML19322C534
| ML19322C534 | |
| Person / Time | |
|---|---|
| Site: | Crane |
| Issue date: | 02/02/1979 |
| From: | Janis J BABCOCK & WILCOX CO. |
| To: | Hilbish J METROPOLITAN EDISON CO. |
| References | |
| TASK-TF, TASK-TMR TMI-79-16, NUDOCS 8001170863 | |
| Download: ML19322C534 (4) | |
Text
'
...... v.v>vn
.E. R. Kane '
/
G. M. Olds e
J. D. Phinney Babcock &Wilcox
,,,, c,,,,, so, o,,,,
P.o. Bcx 1200, Lynchburg, va. 24505 Telephone: (804) 334-5111 February 2,1979 TMI-79-16 Mr. J. F. Hilbish Manager, Licensing Metropolitan Edison Company Post Office Box 542 Reading, PA 19603
Subject:
Three Mile Island fluclear Station toss of Pressurizer Level Indication
Reference:
f1RC Letter, J. E. Foster to J. H. Taylor,' dated 1/31/79
Dear Mr. Hilbish:
B&W has received the attached request for information concerning the loss of pressurizer level indication at BSU plants from the !;RC Region III office. The Region I_II office is requesting this. information based on theirl feeling that a. loss' of pressurizer level indication violates (Criterion 13 - Instrumentation 'and Centrol, which states, " Instrumentation shall be provided to monitor variables and systems over their anticipated range for normal operation, for anticipated operational occurrences, and for accident conditions as appropriate to ensure adequate safety,...."
Because of the tight schedule of their request, we would appreciate your prompt response to this request.
If you choose to supply the requested information for your plant (s), it would be desirable for the information to be in our hands by February 8,1979, so we can compile the information and develop the proper strategy.
Present plans call for aIstrategy meeting on Tuesday, February 13, 1979, in Lynchburg to discuss the concern for utilities that plan to attend the February 14, 1979, meeting.
Please contact us by February 8 if you plan to attend and indicate whether you will investigate past occurrences at your plant.
Very truly j
='
JoelT.(Jan'is U i' "
.1 Service Manager j
JTJ/ web
~
~
Attachment i
3[
cc:
R. M. Klingaman L. L. Lawyer 8001170 G. P. Miller J. L. Seelinger J. B. Logan C. R. Montgomery 5
ine saecock & w.iccx com::any / tstaansneo iee7
.I
/Jd/V/VN
/ /t ) t.
/.
=
Babcock &Wilcox
,,,,, c,,,,, c,,,,
P.O. Box 1260. Lynchburg. Va. 245c5 Telephone: (804) 384 5111 February 2,1979 Aft 0-79-13 Mr. D. H. Williams Manager, Licensing Arkansas Power & Light Company P.O. Box 551 Little Rock, Arkansas 72203
Subject:
Arkansas fluclear One - Unit 1 Pressurizer Level Meeting With flRC
Dear Mr. Williams:
As discussed with you in a telecon on February 2,1979, B&W has received the attached request for information concerning the loss of pressurizer levei indication at B&W plants from the f4RC Region III office.
The Region III office is requesting this information based on their feeling that a loss of pressurizer level indication violates Criterior.13 -
Instrumentation and Control which states "Instrur.entatier. shall be provided to monitor variables and systems over their anticipated range for normal operations, for anticipated operational occurrences, and for accident conditions as appropriate to ensure adequate safety...".
Because of the tight schedule of their request, we would appreciate your prompt response to this request.
If you choose to supply the requested information for your plant, it would be desirable for the information to be in our hands by 2/8/79 so we can compile the information and develop the proper strategy.
Present plans call for a strategy meeting on Tuesday, February 13, 1979, in Lynchburg to discuss the concern for utilities that plan to attend the February 14, 1979 meeting.
We understand you plan to attend both of these meetings.
If you have any questions in this matter, please advise.
Very truly yours, g
,g.f) h R. C. Luken E 6" l*
Service Manager U E'
~
'M RCL/dsv Attach.
bec *'
J T-cc: J.P. O'Hanlon G.H. Miller J.D. Phi""0Y D.R. Sikes T.F. Scott R.P. Lockett, Jr.
1 BabcockaWilcox
~
rower cemeratica creuo P.o. Box 1260. Lynenburg. Va. 245c5 Telephone: (804) 384 5111 February 2,1979
& R.S 12 Mr. D.G. Raasch Manager Generation Engineering Sacramento Municipal Utility District Rancho Seco nuclear Station Route 1, Box 550
. Herald, California 95638
Subject:
Rancho Seco Nuclear Generating Station - Unit No.1 Loss of Pressurizer Level Indication Ref:
. NRC Letter, J.E. Foster to J.H. Taylor dated 1/31/79
Dear Mr. Raasch:
B&W has recieved the attached request for information concerning the loss of pressurizer level indication at B&W plants frcm the NRC Region III office.
The Region III office is requesting this information based on their feeling that a loss of pressurizer level indication violates Criterion 13 - Intrumentation and Control which states " Instrumentation shall be proviced to monitor variaales and systems over their anticipated range for normal operations, for anticipated operational eccurrences, and for accident conditions as appropriate to ensure adequate safety, - -
Because of the tight schedule of their request, we would appreciate y~our prompt response to this request.
If you choose to supply the requested information for your plant (s) it would be desirable for the information to be in our hands by 2/8/79 so we can compile the information and develope the proper strategy.
Present plans call for a strategy meeting Tuesday February 13, 1979 in Lynchburg to discuss the concern for utilities that plan to attend the February 14, 1979 meeting.
Please contact us by February 8 if you plan to attend and indicate whether you will investigate past occurrences at yo,ur plant.
ryfsh,$n Very truly yours,
, c 4* ggw ip-
,; i @1 f.; / #
y.y 4
,,,_,,[/
Service Manager bec:
R. Berchin "ER Kane GM Olds JTJ/krd JD Phinney CC:
R.P. Dubre'
-.C. A. Creacy
- Record Ctr. NSS-11/T1.2 R J, Rodr0guez.
J.H. Johnston
).
- )
BabcockaWilcox g,, o,,,,,2, o,,,
P.o. Box 126o. Lynenturg. Va. 2 '50s
" "h " (80438' Sill bec:
CD Russell JD Phinney February 2, 1979 RC Luken ONS-79-35 JH Taylor Record Ctr. fiSS-3/4/9/Tl.2 Mr. K. S. Canady Manager, Projects & Licensing Duke Power Company P.O. Box 33189 Charlotte, NC
Subject:
Oconee fluclear Station Loss of Pressurizer Level During Transients
Reference:
Letter, James E. Foster (NRC) to J. H. Taylor (B&W),
January 31, 1979 (attached).
Dear Mr. Canady:
B&W~ has received the attached request for information concerning the loss of pressurizer level indication at B&W plants from the f:RC Region III office.
The Region III office is requesting this information based on their feeling :nat a loss of pressurizer level indication violates Criterion 13 - Instrumentation and Cor. trol which states " Instrumentation
~ hall be proviced to monitor vartaoles anc systems over their antici-spated range for normal operations, for anticioated operational occurrences, and for accident conditions as appropriate to ensure adequate safety...".
Because of the tight schedule of their request, we would appreciate your prompt response to this request.
If you choose to supply the requested informatior, for your plant (s), it would be desirable for the inf:rmation to be in our hands by February 8,1979 so we can compile the information and develop the proper startegy.
Present plans call for a strategy meeting Tuesday, February 13,1979, in lynchburg to discuss the concern for utilities that plan to attend the
. February 14, 1979 meeting.
Please notify CD Russell or myself if you plan to attend and indicate whether you will investigate past occurrences at your plant.
Very truly yours, is,c W m 6 R. P. Williamson Associate Service Manager RPW/hh mp Q.,,m o u w k f fk i
cc:
RL Gill f
e
_