r P:wer Genzratien Group P.O. 3:x 1250. Lynchburg.Va. 24sC3 Teleph:ne: (e04) 35t s111
~
April 4,1979 TMI-79-47 WLLY McMo
"=
Mr. G. P. Miller
. g y g,g Station Superintendent s
Metropolitan Edison Company P.O. Bux 480 Middletown, PA 17057
Subject:
Three Mile Island uclear Generating Station - Unit 1 TMI-2 Loss of Feedwater Transient j
Dear Mr. Miller:
~
Although details of the causes and. course of. events of the incident at Metropolitan Edisen's THI-2; plant on March.28,197.9 are still being developed, it appears that.the incident was initiated by a loss-of-main feedwater ficw (LOPJ) and bat a distinguishing characteristic of this transient ccmpared to other previous LOFW transients was the securing of the High Pressure Injection,(HPI) system.
Consequently, all operating plants are advised to simplement-the following imediately:,
If the HPI system has actuated because of low pressure condition, it cust remain in cparatien until either:
l '. Both LPI pumps are in operatien and ficwing at a r' ate in excess of 1000 GPM each a.1d the situation has been stable for 20 minutes.
Og 2.
TheHPIsystemhasbeeninoperationforgominutesandallhet and cold leg temperatures are at least 50 below the saturation temperature for tne existing RCS pressure.
If 500 subccoling can-not be maintained, the HPI shall be reactivated.
If,the HPI system has been activated and if RC pumps are in operation, I
at least one RCP pump per loop should be maintained.
This information supplements that previously transmitted..If you have any questions regarding this advisory, please advise.
yery truly yours,
.4. J. AJ DnnD bDlm Al G. T. Fairburn.
Service Manager fUUn UHlUI TIL GTF/hh cc: Fli Klingaman bec: JD Phinney
~-
JF Hilbish RL Pittman
~ LL Lawyer TM Dixens JL Seelinger GM Olds CR Montgomery HA Bailey
.he LC Rogers Record Ctr. NSS-5 T1.2 SL Smith nc eadcxx & wac:n company i Er
-.._0 0117 0 3 9g 8
~
.