ML19322A434

From kanterella
Jump to navigation Jump to search
RO 76-8/4P:blocked Flow Signal from Flow Recorder FR-123 Caused Failure of Discharge Valve from Waste Decay Tank to Close.Caused by Improper test-normal Switch Position.Switch Set at Proper Position
ML19322A434
Person / Time
Site: Crane 
Issue date: 02/21/1976
From: Colitz J
METROPOLITAN EDISON CO.
To:
References
NUDOCS 7910240876
Download: ML19322A434 (2)


Text

O e

e

~.

27MW,7g

~

cc..

/

/

r- - -n METROPOLFTAN EOtSON COMPANY sunci.mvcr crurm euruc oriurors conrons.nor.-

!GT OFFICE DOX 400 M1DDLE. TOWN. PENNSYW ANtA T7057 TELEPHONE 717 944 4C4

(), o/. Q h ZT Februwy 1976 0

PM Hr. J. P'. O'RefTTy 5

IIfrectorate of Regulatory Operations ooE Region 1 O3' 7

m 631 Park Avenue f

King of Prussia,. Penna.

T7406.

1k a

Operatingt License DPR-50 Docket Na. 5&-229 SUlIJECT-Reportchie Uccurrence No. 76-8/4P

Dear Mr. O'RefTTy:

This telecram-is to confirty the telecon between Mr. Lee Iaessard-(Regior I-fiRC1'and.*!r. J. J. CcIf tz. (TRI-Unit I Superintendent} at

/'

0030 frours on 27 February 1976 A violation-of' Environacata1f Technicai specificatfen Section 2*.3.2.a.4 cccurred in..t. Tat flox recorder- (FR-T23) would not ht-ve cTosed the discharge valve (WDS-7-77) front the-Waste Gas Decay TanL-on high flex. The interlock was xnt functional because tire recareer wearId not resptmd to a ficw sigreal.

1 The oss reTease had been in progress for abont ten (TO) minutes an:f was icnediateTy terminated when irt was dei.m.iined that the-recorder was not responding.

tipois checkntat and calibration of ficw recorder (FR-123) it was f

found that the Test-fiormal Switch associated witfr the recorder was in the " Test" pasttien wirtctr bypasses the input signal to the recorder.

The recorder was. caTibrated and the. Test-Nurmal Switch was ~

l 7910240

/!f

[

O O

Mr. J. P. O'Rei1Ty 2T February 1976 returned to the Normai Position. The Waste Gas Decay Tank was, then released accorting to approved procedures.

The precedure for Release of Gas Decay Tanks will be revised to include verification of the Test-Normal Switch position prior ta release.

Very truly yours, 99 ut

~

~

J. J. Coliti Unit I Superintendent Three Mile Islarui Nuclear Station JJC/ pas.

4

.e.

]D D

~

o u JU D '9'T A

. J3 L v

2 l

l

__