ML19321B328

From kanterella
Jump to navigation Jump to search
Forwards Revised Summary Page for 800616 Response to NUREG-0588
ML19321B328
Person / Time
Site: Sequoyah 
Issue date: 07/28/1980
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: Schwencer A
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0588, RTR-NUREG-588 NUDOCS 8007310412
Download: ML19321B328 (2)


Text

.

.o s 400 Chestnut Street Tower II July 28, 1980 Director of Nuclear Reactor Regulation Attention:

Mr. A. Schwencer, Chief Light Water Reactors Branch No. 2 Division of Licensing U.S. Nuclear Regulatory Commission Washington, DC 20555

Dear Mr. Schwencer:

In the Matter of the Application of

)

Docket No. 50-327 Tennessee Valley Authority

)

1

Reference:

Letter frem L. M. Mills to A. Schwencer dated June 16,_1980 In TVA's response to NUREG-0588 for Sequoyah Nuclear Plant, provided-by the referenced letter, TVA identified _several items which lacked sufficient environmental qualification documentation.

Enclosed is a revised summary page for our response to NUREG-0S88 which details the current status of these items.

Very truly yours, TENNESSEE VALLEY AUTHORITY sk ');. 'p,m

,.y,-

\\_

L. M. Mills, Manager Nuclear Regulation and Safety Enclosure i

h te t

\\

O

\\

W ef

\\

A 4

1 s u, W

f 300'rsio Ill

d ENCLOSURE SEQUOYAH NUCLEAR PLANT REVISED

SUMMARY

PAGE FOR NUREG-0588 RESPONSE 1.

Inside Containment a.

There are no open items for Category a and b equipment.

b.

There are three open items for Category c equipment. The ASCO solenoid valves are being replaced with fully qualified units. The ventilation fan motors are being analyzed to determine the maximum allowable ambient service conditions.

This equipment does not perform a safety function; therefore, no replacement is required before full power operation.

2.

Annulus a.

The two solenoid valves have been replaced with fully qualified units.

b.

The Barton Model 288A Differential Pressure Switches are being modified. The Robertshaw Model 445ElP I/P Transducers are being relocated. This work will be completed before exceeding 5 percent power.

c.

The Comsip hydrogen analyzer was qualified for an accident (one year integrated) dose only and is being analyzed to determine effects of additional normal dose. Preliminary analysis results justify safe plant operation with the "in situ" equipment.

How-ever, autoclave testing on similar components will be performed to verify acceptability of equipment.

3.

Outside containment a.

Equipment subjected to adverse environments caused by HELB lacking qualification was identified and replaced or moved, b.

There are a number of items lacking sufficient documentation

~

_to determine the exact qualified service condition envelopes.

A number of pump motors and fan motors, as well as a few other components fall into this category (see last part of reviews in section D).

TVA.is pursuing adequate documentation of the environmental qualification of these items.

Preliminary information indicates that-the equipment is qualified and this is primarily a " paper" problem.

O O

6

~

~ '

e

, -