._

.n' V

%rm NRC 618 U.S. NUCLEAR REGULt. TORY CoMMISsloN CRM CERTIFICATE OF COMPLIANCE For Radioactive Materials Packages 1.(a) Certificate Number 1.(b) Revision No.

1.lc) Package Identification No.

1.(d) Pages No. 1.(e) Total No. Pages 6744 4

IK A /6744 /A#

1

?

2. PREAM8t.E 2.{a)

This certificate is issued to satisfy Sections Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-toa and173.393a,173.394 146-.19-100 of the Department of Transport 1 tion Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item s below, meets the safety standards set forth in Subpart C of Title 10. Code of

, Federal Regulations, Part 71,'* Packaging of Radioactive Materials for Transport and Transportation of Radioactive Mat Certain Conditions.**

2.(c)

This certificate does notteliue the' consignor from compliance with any requirement of the regulations of the U.s. Depa Transportation or other applicable regutetory agencies, including the government of any country through or into w will be transparted.

3. This certificate is issued on the basis of a safety analysis report of the package design or application-

' 3.(a)

Prepared by (Name and address):

3.(b) ' Title and identification of report or" application:

Combustion Engineering, Inc.

Route 21-A Combustion Engineering, Inc. application dated June 20, 1980.

Hematite, M0 63047 3.fe) Docket No.

7]-62g4

  • 4. CONDITIONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of to CFR 71, as applicable, and the c

,in item s below.

s. Description of Packaging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and

References:

(a) Packaging (1) Model No.:

UNC-2901 (2). Description Is maximum 10.80-inch square by ~30-inch long inner container constructed of minimum 14 gage steel, with bolted and gasketed top flange closure and sealed welded bottom sheet.

Inner container is centered and supported in a 22.5-inch ID by 34-inch high 18 gage steel drum with 16 gage head and 00T Specification 17H closure by asbestos sheet, plywood, hardboard, and insulating material.

Gross weight of package - 660 pounds.

l (3) Drawings The packaging is constructed in accordance with Combustion Engineering, Inc.

Drawing No. D-5007-8086, Revision 3.

4 (5) Contents (1) Type and form of material Uranium dioxide as powder or sintered pellets.

Uranium may be enriched to a maximum 4.1 w/o in the U-235 isotope.

The maximum H/U atomic ratio, considering all sources of hydrogenous material within the inner container for powder or within the boundary of the pellet array for pellet packages, shall not exceed 4.5.

[O7 8.007240

7

~

P ge 2 - Certificate No. 6294 - Revision No. 4 - Docket No. 71-6294 r

5.

>(b) Contents (2) Maximum quantity of material per package (i) 427 pounds containing not more than 4.79 kgs U-235 as sintered pellets enriched to a maximum 3.75 w N in the U-235 isotope, or 3.93 kgs U-235 as sintered pellets enriched to a maximum 4.1 w/o in the U-235 isotope.

Pellets shall be packaged in accordance with Combustion Engineering, Inc.

Drawing No. D-5008-8192, Rev. 5.

l (ii) 230poundscontainingnotmorethan3.60kgsU-235aspowderorsinteredl pelJets packaged in accordance with United Nuclear Corporation Drawing No. A-5007-20ll.

(c) Fissile Class II and III g

(1) Minimum transport index to be shown on label for Class II 2.0 (2) Maximum number of packages per shipment for Class III 50 6.

Prior to each shipment the insert (containment vessel) gasket shal' be inspected.

This gasket shall be replaced if inspection shows any defects or e nry twelve (12) months, whichever occurs first.

7.

The package authorized by this certificate is hereby approved for use under the general license provisiota of 10 CFR 671.12(b).

8.

Expiration date:

July 31, 1985.

l REFEREN_C_E Combustion Engineering, Inc., application dated June 20, 1980.

l FOR THE U.S. NUCLEAR REGULATORY COMMISSION

[

Charles E. MacDonaid, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety JUL 151980 Date:

i

?Q

_,