a DOCKET NO. 50-213

, - ~.

\\,s I

ATTACHMENT 1 HADDAM NECK PLANT PROPOSED REVISIONS TO ENVIRONMENTAL TECHNICAL SPECIFICATIONS JULY, 1980 8007240070

DEC 2 71974 Specification 2.4.1.6 requires that the licensee maintain and operate the equipment installed in the liquid waste systems to reduce the release of radioactive materials in liquid effluents to as low as practicable consistent with the requirements of 10 CFR Part 50.36a.

Normal use and maintenance of installed equipment,in the liquid waste system provides reasonable assurance that the quantity released will not exceed the design objectiva.

In order to keep releases of radio-active materials as low as practicable, the specification requires operation of equipment whenever it appears that the projected j

cumulative discharge rate will exceed one-fourth of this design objective annual quantity during any calendar quarter.

Specification 2.4.1.7 limits the amount of radioactive material that could be inadvertently released to the environment to an amount that will not exceed the Technical Specificetion limit.

d In addition to limiting conditions for operation listed under Specifications 2.4.1.2 and 2.4.1.3, the reporting requirements of i

Specification 2.4.1.8 delineate that the licensee shall identify the cause whenever the cumulative release of radioactive materials in liquid waste e'ffluents exceeds one-half the design objective annual quantity during any calendar quarter and describe the pro-posed program of action to reduce such releases to design objective levels on timely basis. This report must be filed within 30 days l

following the calendar quarter in which the release occurred.

)

The sampling and monitoring requirements given under Specification 2.4.2 provide assurance that radioactive materials'in liquid wastes are properly controlled and monitored in conformance with the requirements of Design Criteria 60 and 64. These requirements provide the data for the licensee and the Commission to evaluate the plant's performance relative to radioactive liquid wastes released to the environment. Reports on the quantities of' radio-active materials released in liquid waste effluents are furnished to the Constission according to Section 5.6.1 of t'hese Technical Specifications in conformance with Regulatory Guide 1.21.

On the basis of such reportis and any additional information-the Commission may from time to time require the licensee to take such action as the Commission deems approp' ate.

The points of release to the environment to be monitored in Section 2.4.2 include all the monitored release points as provided for in Table 2.4-3.

2.4.3 Specifications for Gaseous Weste Effluents t

2.4.3.1 (1) The release rate limit of noble gases from the site averaged over any one (1) hour period shall be:

i

- 94 I

+ 460 5

<1 Q

1 1y i

)

4

}.4-5

..